2

Efficiency Ratio) with enhanced ratings of 
up to 15.75 SEER. Sophisticated heat 
transfer surfaces utilized in Carrier’s 
38TSA design allow heat to easily be 
transferred to the outdoor air and requires 
less energy. The scroll compressor found in 
the 38TSA design performs quietly and 
adds to the overall efficiency of the system. 
Finally, Carrier’s Puron refrigerant 
operates more efficiently than R-22 
refrigerant found in other systems. The 
efficiency levels provided by the 38TSA 
provide end users with lower costs of 
operation than traditional air conditioning 
systems. 38TSA models are shipped with a 
Puron TXV (thermostatic expansion valve) 
for field installation. The installation of this 
TXV adds to the efficiency of the 38TSA’s.

 

Assured Future Service

 

— By utilizing 

the environmentally sound refrigerant, 
Puron, 38TSA models will remain 
serviceable well into the future. The Clean 
Air Act of 1990 has placed a cap on 
production of most other refrigerants 
which has scheduled reductions beginning 
in 2004. The resulting cap in production 
ultimately results in a complete ban on 
many other refrigerants in new equipment 
by the year 2010. These changes, required 
by federal law, mean the supply of other 
refrigerants may be limited in the near 
future making Puron the correct choice 
when considering long term serviceability.

 

Highly Reliable Performance

 

— Is 

delivered through the superior design of the 
system and componentry. The reliability of 
the WeatherMaker models have been 
proven to provide the lowest incidence of 
warranty service of any product in the 
Carrier family in its first 2 years of service. 
Long term reliability is assured through the 
use of both high and low pressure switches 

which will not allow the system to operate 
in the event of a significant change in 
operating pressure. In doing this, the 
system is protected from damage if an 
unusual condition arises. Finally, Carrier 
includes a special liquid line filter drier 
designed to trap moisture and 
contaminants which could otherwise 
shorten the life of the system.

 

Carrier’s Silencer System

 

— Is one of 

the most sought after features of the 
38TSA family. Extremely low operating 
sound is the result of special attention to the 
air moving through the outdoor unit, a 
specially designed sound enclosure 
surrounding the compressor, and an 
exclusive laminated plate beneath the 
compressor to eliminate sound 
transmission to the rest of the system.

 

Application Versatility

 

— Carrier’s 

systems utilizing Puron refrigerant have 
the same application guidelines as other 
systems. Applications which include long 
line sets (50 to 175 ft) or applications 
which require the system to operate at low 
outdoor temperatures (below 55°F, 
12.8°C) are approved under Carrier’s 
standard guidelines.

 

Carrier Coils and Fan Coils to Complete 
the System

 

— Carrier specially designs 

both the outdoor product and indoor coil 
products to operate with assured reliability 
and performance. A wide range of indoor 
coil options are listed in the ratings section 
of this publication.

 

Special Protective Devices

 

— High and 

low pressure switches and internal 
protection in the compressor including 
temperature and current sensing overloads 
prevent operation under potentially 
damaging circumstances. A special liquid 

line filter drier designed to trap nearly 4 
times the volume of contaminants of 
standard driers provides superior 
protection from moisture trapped in the 
system.

 

Electrical Range

 

— 208/230v, single 

phase.

 

Wide Range of Sizes

 

— Available in 

four sizes: 2, 2 1/2, 3, and 3 1/2 tons.

 

Totally Enclosed Fan Motor

 

Protected from adverse weather 
conditions.

 

Unit Design

 

— Enhanced copper and 

aluminum heat transfer surfaces with 
vertical air discharge to direct air up and 
away from the area.

 

External Service Valves

 

— Both service 

valves are back seating type valves which 
are externally located. These unique valves 
allow service technicians to evacuate or 
charge the system in less time than 
standard service valves.

 

Easy Serviceability

 

— Easy removal of 

panels and wire dome provides access to 
both electrical and refrigerant carrying 
components, simplifying installation and 
service.

 

Agency Approvals

 

— 38TSA models 

are listed with UL, c-UL, ARI, CEC, and 
CSA-EEV. Special endorsements have 
also been awarded these products by 
Energy Star® which recognizes energy 
efficient products.

 

Limited Warranty

 

— A standard one 

year warranty on parts with extended 
warranty coverage on the compressor for 
a total of 10 years. A five year warranty 
is offered on the outdoor coil. Optional 
warranties are available through your 
Carrier distributor.

  

M

A

N

U

F

A

C

T

U

R

E

R

CE

RT

IFIED

TO ARI

AS

C

O

M

P

L

Y

IN

G
W
IT

H

A

RI

STANDARD

21

0

U

N

IT

A

R

Y

AIR

CO

N

D

IT

IO

N

IN

G

EQUIPMENT

 

CERTIFICATION APPLIES ONLY WHEN THE
COMPLETE SYSTEM IS LISTED WITH ARI.

REGISTERED QUALITY SYSTEM

As an ENERGY STAR

 

®

 

 partner, Carrier Corporation has 

determined that this product meets the ENERGY 

STAR

 

®

 

 guidelines for energy efficiency.

  

Summary of Contents for Puron 38TSA

Page 1: ...ing systems as the traditional refrigerant R 22 has been Puron refrigerant is in service in thousands of systems providing highly reliable environmentally sound performance For specific R 22 phase out information see your Carrier distributor WeatherArmor III System The casingsteelisgalvanizedandcoatedwitha layer of zinc phosphate A modified polyester powder coating is then applied and baked on pro...

Page 2: ... transmission to the rest of the system Application Versatility Carrier s systems utilizing Puron refrigerant have the same application guidelines as other systems Applications which include long line sets 50 to 175 ft or applications which require the system to operate at low outdoor temperatures below 55 F 12 8 C are approved under Carrier s standard guidelines CarrierCoilsandFanCoilstoComplete ...

Page 3: ...t Lb 290 290 293 294 COMPRESSOR Copeland Manufacturer Type Scroll REFRIGERANT Puron Control AccuRater Bypass Type Charge Lb 8 76 9 11 9 83 9 66 COND FAN Propeller Type Direct Drive Air Discharge Vertical Air Qty CFM 2400 2400 2800 2800 Motor HP 1 8 1 8 1 5 1 5 Motor RPM 825 825 825 825 COND COIL Copper Tube Aluminum Plate Fin Face Area Sq ft 18 25 18 25 18 25 18 25 Fins per In 20 20 20 20 Rows 2 2...

Page 4: ...1LLS Liquid Line Solenoid Valve All Sizes KSASF0101AAA Support Feet All Sizes KAACF0801MED Coastal Filter All Sizes THERMOSTAT SUBBASE PKG DESCRIPTION TSTATCCNAC01 B Thermostat Auto Changeover Non Programmable F C 1 Stage Heat 1 Stage Cool TSTATCCPAC01 B Thermostat Auto Changeover 7 Day Programmable F C 1 Stage Heat 1 Stage Cool TSTATCCPRH01 B Thermidistat Control Non Programmable Programmable The...

Page 5: ...oller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits approximately 100 F 37 8 C high and 60 F 15 5 C low The control will maintain working head pressure at low ambient temperatures down to 0 F 17 8 C when properly install...

Page 6: ...A Full Load Amps LRA Locked Rotor Arms MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 v on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection Sound power dBA UNIT SIZE SERIES V PH OPER VOLTS COMPR FAN FLA MCA 60 C MIN WIRE SIZE 75 C MIN WIRE SIZE 60 C MAX LENGTH F...

Page 7: ...roper airflow Minimum outdoor operating ambient in cooling mode is 55 F unless low ambient control is used max 125 F 2 Series designation is the 13th position of the unit model number 3 Center of gravity 4 NOTES A97084 DIMENSIONS IN UNIT SIZE SERIES UNIT DIMENSIONS MINIMUM MOUNTING PAD DIMENSIONS A B C D E F G H J K L M N 024 30 32 39 13 16 30 34 15 16 4 9 3 4 27 1 2 33 7 8 5 8 8 3 16 16 3 4 19 1 ...

Page 8: ...ANF030 24 600 TDR TXV 14 00 14 00 12 15 FX4ANF036 25 000 TDR TXV 13 60 13 60 11 85 COILS 58MVP040 14 VARIABLE SPEED FURNACE CC5A CD5AW030 24 600 TDR TXV 14 50 14 50 12 60 CC5A CD5AW036 25 000 TDR TXV 15 00 15 00 13 15 CK5A CK5BW030 24 600 TDR TXV 14 50 14 50 12 75 CK5A CK5BW036 25 000 TDR TXV 15 00 15 00 13 20 COILS 58MVP060 14 VARIABLE SPEED FURNACE CC5A CD5AA036 25 000 TDR TXV 15 00 15 00 13 10 ...

Page 9: ...14 00 12 15 FX4ANF036 29 600 TDR TXV 13 85 13 85 11 90 FX4ANF042 30 000 TDR TXV 13 60 13 60 11 90 COILS 58MVP040 14 VARIABLE SPEED FURNACE CC5A CD5AA042 30 000 TDR TXV 15 00 15 00 13 00 CC5A CD5AW030 29 000 TDR TXV 14 00 14 00 12 30 CD5AW036 29 600 TDR TXV 15 00 15 00 12 90 CK5A CK5BA042 30 000 TDR TXV 15 00 15 00 13 05 CK5A CK5BW030 29 000 TDR TXV 14 00 14 00 12 35 CK5A CK5BW036 29 600 TDR TXV 15...

Page 10: ...2 10 CF5AA036 35 000 TXV 13 50 13 50 11 90 CF5AA048 36 000 TXV 13 80 13 80 12 00 CK3BA036 35 000 TXV 13 70 13 70 11 95 CK3BA042 35 600 TXV 13 70 13 70 11 95 CK3BA048 36 000 TXV 14 00 14 00 12 05 CK5A CK5BA036 35 000 TXV 13 70 13 70 11 95 CK5A CK5BA042 35 600 TXV 13 70 13 70 11 95 CK5A CK5BA048 36 000 TXV 14 00 14 00 12 05 CK5A CK5BN036 35 000 TXV 13 70 13 70 12 05 CK5A CK5BN042 35 600 TXV 13 70 13...

Page 11: ...K5BA042 35 600 TDR TXV 15 00 15 00 13 10 CK5A CK5BA048 36 000 TDR TXV 15 00 15 00 13 20 CK5A CK5BW036 35 000 TDR TXV 15 00 15 00 13 05 COILS 58MVP120 20 VARIABLE SPEED FURNACE CC5A CD5AA042 35 600 TDR TXV 15 00 15 00 13 00 CC5A CD5AW048 36 000 TDR TXV 15 00 15 00 13 00 CD5AW036 35 000 TDR TXV 15 00 15 00 12 90 CK5A CK5BW036 35 000 TDR TXV 15 00 15 00 12 95 CK5A CK5BW048 36 000 TDR TXV 15 00 15 00 ...

Page 12: ...NB006 42 000 TDR TXV 15 10 15 10 13 60 FV4ANF003 40 000 TDR TXV 14 30 14 30 12 65 FV4ANF005 41 500 TDR TXV 15 00 15 00 13 20 FX4ANB060 42 000 TDR TXV 13 50 13 50 11 95 FX4ANF042 40 000 TDR TXV 13 50 13 50 11 70 FX4ANF048 41 000 TDR TXV 13 60 13 60 11 90 COILS 58MVP040 14 VARIABLE SPEED FURNACE CC5A CD5AA042 40 000 TDR TXV 14 00 14 00 12 15 CC5A CD5AW048 41 000 TDR TXV 14 00 14 00 12 30 CK5A CK5BA0...

Page 13: ...X060 42 000 TDR TXV 15 00 15 00 13 15 COILS 58MVP120 20 VARIABLE SPEED FURNACE CC5A CD5AA042 40 000 TDR TXV 14 50 14 50 12 55 CC5A CD5AA060 41 000 TDR TXV 14 50 14 50 12 60 CC5A CD5AW048 41 000 TDR TXV 14 50 14 50 12 60 CC5A CD5AW060 42 000 TDR TXV 15 00 15 00 12 95 CK3BA060 41 500 TDR TXV 14 50 14 50 12 95 CK5A CK5BA042 40 000 TDR TXV 14 50 14 50 12 55 CK5A CK5BA060 41 500 TDR TXV 14 50 14 50 12 ...

Page 14: ...7 8 2 33 21 1 17 2 2 57 19 5 16 5 2 83 62 26 1 24 4 1 71 24 9 23 8 1 90 23 7 23 2 2 10 22 3 22 3 2 32 21 3 21 3 2 57 20 0 20 0 2 83 57 25 7 25 7 1 71 24 7 24 7 1 90 23 7 23 7 2 10 22 4 22 4 2 32 21 2 21 2 2 57 20 0 20 0 2 84 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5AA 024 0 96 1 0...

Page 15: ...3 07 23 0 20 9 3 39 62 31 7 31 2 2 08 30 2 30 2 2 29 28 8 28 8 2 52 27 5 27 5 2 79 25 9 25 9 3 08 24 0 24 0 3 39 57 31 6 31 6 2 08 30 3 30 3 2 29 28 9 28 9 2 53 27 4 27 4 2 79 25 7 25 7 3 07 24 1 24 1 3 39 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A CD5AA 030 0 97 1 00 FX4ANF 030 0...

Page 16: ... 3 34 57 30 7 30 7 2 03 29 4 29 4 2 24 28 1 28 1 2 47 26 6 26 6 2 74 25 0 25 0 3 02 23 5 23 5 3 34 1125 72 36 7 19 3 2 10 34 5 18 5 2 30 32 1 17 7 2 53 29 9 16 9 2 79 27 8 16 2 3 07 25 6 15 5 3 38 67 33 9 25 4 2 09 32 1 24 7 2 30 30 1 23 9 2 53 28 1 23 1 2 78 26 0 22 3 3 07 23 6 21 4 3 37 63 31 7 24 7 2 08 30 1 24 0 2 29 28 4 23 3 2 52 26 7 22 5 2 78 24 8 21 7 3 07 23 0 20 9 3 39 62 31 7 31 2 2 08...

Page 17: ...6 30 3 30 3 3 70 27 9 27 9 4 07 57 37 7 37 7 2 48 36 1 36 1 2 74 34 4 34 4 3 04 32 5 32 5 3 36 30 4 30 4 3 71 28 0 28 0 4 08 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CK5A CK5BT 048 1 00 1 00 FV4ANF 002 0 99 0 95 CC5A CD5AA 036 0 97 1 00 003 0 99 0 91 042 0 99 1 00 005 1 00 0 91 CC5A ...

Page 18: ...33 2 19 1 3 70 30 5 18 2 4 08 67 40 5 29 9 2 48 38 5 29 1 2 74 36 3 28 3 3 04 33 9 27 4 3 36 31 4 26 4 3 71 28 5 25 3 4 08 63 37 9 29 1 2 48 36 0 28 3 2 74 33 9 27 4 3 04 31 7 26 4 3 36 29 3 25 4 3 70 26 6 24 3 4 06 62 37 8 36 8 2 48 36 1 35 8 2 74 34 3 34 3 3 04 32 4 32 4 3 36 30 3 30 3 3 70 27 9 27 9 4 07 57 37 7 37 7 2 48 36 1 36 1 2 74 34 4 34 4 3 04 32 5 32 5 3 36 30 4 30 4 3 71 28 0 28 0 4 0...

Page 19: ... 5 42 5 3 21 40 5 40 5 3 55 38 3 38 3 3 92 35 9 35 9 4 34 33 6 33 6 4 80 57 44 6 44 6 2 90 42 6 42 6 3 21 40 6 40 6 3 55 38 4 38 4 3 93 36 0 36 0 4 34 33 7 33 7 4 80 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A CD5AA 042 0 95 1 00 FV4ANB 006 1 00 0 91 060 0 99 1 00 FV4ANF 003 0 95 0...

Page 20: ...36 3 29 6 4 27 33 6 28 6 4 72 63 44 2 33 0 2 83 41 9 32 0 3 14 39 6 31 0 3 47 37 1 30 0 3 85 34 5 28 8 4 25 32 0 27 8 4 71 62 43 8 41 5 2 83 41 7 40 5 3 13 39 5 39 3 3 47 37 4 37 4 3 85 35 2 35 2 4 26 33 0 33 0 4 72 57 43 3 43 3 2 82 41 5 41 5 3 13 39 5 39 5 3 47 37 5 37 5 3 85 35 2 35 2 4 27 33 1 33 1 4 73 1575 72 51 1 27 0 2 95 48 3 26 0 3 26 44 5 24 7 3 58 41 8 23 8 3 95 38 5 22 7 4 35 35 5 21 ...

Page 21: ...127 0 2 64 18 8 136 0 2 96 40 TCG SDT KW 32 9 69 8 1 29 31 2 79 4 1 46 29 5 89 1 1 65 27 8 98 7 1 86 26 0 108 0 2 09 24 3 118 0 2 36 22 5 127 0 2 65 20 6 137 0 2 97 45 TCG SDT KW 36 0 71 1 1 30 34 1 80 7 1 47 32 2 90 2 1 66 30 4 99 8 1 87 28 5 109 0 2 10 26 6 119 0 2 37 24 7 128 0 2 66 22 6 138 0 2 98 50 TCG SDT KW 39 2 72 4 1 32 37 2 82 0 1 48 35 2 91 5 1 67 33 2 101 0 1 88 31 1 111 0 2 12 29 1 1...

Page 22: ... further consideration For buried lines longer than 3 ft consult your local distributor 8 Use only copper wire for electric connection at unit Aluminum and clad aluminum are not acceptable for the type of connector provided 9 Do not apply capillary tube indoor coils to these units 10 Factory supplied filter drier must be installed 11 Do not deviate from factory supplied TXV s and Liquid Line Solen...

Page 23: ...23 Typical installation A98600 AIR CLEANER FURNACE FURNACE COIL AIR CONDITIONER COMFORT VENTILATOR HUMIDIFIER COMFORT ZONE II CONTROL CENTER ...

Page 24: ...P Program Unit Cabinet Unit cabinet will be constructed of galvanized steel bonderized and coated with a powder coat paint Fans Condenser fan will be direct drive propeller type discharging air upward Air Cooled Split System Air Conditioner 38TSA 2 to 3 1 2 Tons Nominal Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts wil...

Reviews: