4–55
T-362
4.6.6
Pre-Trip Data Recording
The DataCORDER will record the initiation of a pre-trip test (see
) and the results of each test included
in pre-trip. The data is time-stamped and may be extracted via the Data Retrieval program. See
description of the data stored in the DataCORDER for each corresponding pre-trip test.
Table 4–11 DataCORDER Pre-Trip Result Records
Test Title
Data
P1-0 Heater On
Pass / Fail / Skip Result,
Change in current for Phase A, B & C
P1-1 Heater Off
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P2-0 Condenser Fan On
Pass / Fail / Skip Result, Water pressure switch (WPS) -
Open/Closed, Change in currents for Phase A, B and C
P2-1 Condenser Fan Off
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P3-0 Low Speed Evaporator Fan On
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P3-1 Low Speed Evaporator Fan Off
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P4-0 High Speed Evaporator Fan On
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P4-1 High Speed Evaporator Fan Off
Pass / Fail / Skip Result,
Change in currents for Phase A, B & C
P5-0 Supply / Return Probe Test
Pass / Fail / Skip Result, STS, RTS, SRS and RRS
P5-1 Secondary Supply Probe (SRS) Test
Pass / Fail / Skip
P5-2 Secondary Return Probe (RRS) Test
Pass / Fail / Skip
P5-3 Evaporator Fan Direction Test
Pass / Fail / Skip
P5-7 Primary vs. Secondary Evaporator
Temperature Sensor Test
Pass / Fail / Skip
P5-8 Future Expansion
Not Run
P5-9 Primary vs. Secondary Evaporator
Pressure Transducer Test
Pass / Fail / Skip
P5-10 Humidity Sensor Controller Configuration
Verification Test
Pass / Fail / Skip
P5-11 Humidity Sensor Installation Verification
Test
Pass / Fail / Skip
P5-12 Humidity Sensor Range Check Test
Pass / Fail / Skip
P6-0 Discharge Thermistor Test
Pass / Fail / Skip
P6-1 Evaporator Temperature Sensor (Suction)
Test
Pass / Fail / Skip
P6-2 Discharge Pressure Transducer Test
Pass / Fail / Skip
P6-3 Suction Pressure Transducer Test
Pass / Fail / Skip
P6-4 Compressor Current Draw Test
Pass / Fail / Skip
P6-5 Compressor Leak Test
Pass / Fail / Skip
P6-6 Economizer Valve Test
Pass / Fail / Skip