4.2 Controller Software
The controller software is a custom designed program that is subdivided into configuration software and
operational software. The controller software performs the following functions:
• Control supply or return air temperature to required limits, provide modulated refrigeration operation,
economized operation, unloaded operation, electric heat control, and defrost. Defrost is performed to clear
buildup of frost and ice to ensure proper air flow across the evaporator coil.
• Provide default independent readouts of setpoint and supply or return air temperatures.
• Provide ability to read and (if applicable) modify the configuration software variables, operating software
function codes and alarm code indications.
• Provide a pre-trip step-by-step checkout of refrigeration unit performance including: proper component
operation, electronic and refrigeration control operation, heater operation, probe calibration, pressure limiting
and current limiting settings.
• Provide battery-powered ability to access or change selected codes and setpoint without AC power connected.
• Provide the ability to reprogram the software through the use of a memory card.
4.2.1
Configuration Software (CnF Variables)
Configuration software is a variable listing of the components available for use by the operational software. This
software is factory installed in accordance with the equipment fitted and options listed on the original purchase
order. Changes to the configuration software are required only when a new controller has been installed or a
physical change has been made to the unit such as the addition or removal of an option. A configuration variable
. Change to the factory-installed configuration software is achieved via a configuration
card or by communications.
Table 4–3 Controller Configuration Variables
Config Title
Default
Option
CnF04
Enable Dehumidification
On
OFF
CnF08
Evaporator Motor Type
1Ph
3Ph
CnF11
Defrost “Off” Selection
noOFF
OFF
CnF18
Heater Type
Old (Low Watt)
nEW (High Watt)
CnF22
Economy Mode
OFF
Std, Full, CUSt
CnF23
Enable Defrost Interval Save
noSAv
SAv
CnF24
Enable Long Pre-Trip Test Series
Auto (Auto1)
Auto2, Auto3
CnF25
Enable Pre-Trip Data Recording
rSLtS
dAtA
CnF26
Heat Lockout Temperature
Set to -10C
Set to -5C
CnF28
Enable Bulb Mode
NOr
bULb
CnF31
Probe Check
SPEC
Std
CnF33
Enable Snap Freeze
OFF
SnAP
CnF34
Temperature Unit Display
bOth
F, C
CnF37
Electronic Chart Probe
rEtUR
SUPPL, bOth
CnF39
Enable Expanded Current Limits
Out
In
CnF41
Enable Low DTT Setting
Out
In
CnF42
Enable Auto Pre-Trip Trip Start
Out
In
CnF44
Autoslide Enable
Out
LO, UP
CnF45
Low Humidity Enabled
Out
In
CnF46
Quench / Liquid Injection Valve Type
nO
nC
CnF47
Vent Position
OFF
UP, LOW, CUStOM
CnF49
OEM Reset Option
OFF
Std, SPEC, CUSt