PHJ4 and WJH4: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

3

airflow across the coil and reduce the amount of heat absorbed from the

outside air. So, to maintain energy-efficient  operation, your unit has an

automatic defrost mode.
The defrost mode starts at a preset time interval of 60 minutes, although,

it may be reset to 30, 90 or 120 minutes. Defrost will start at the preset

time  only  if  the  ice  is  sufficient  to  interfere  with  normal  heating

operation.
After the ice is melted from the coil, or after a maximum of 10 minutes

in defrost mode, the unit automatically switches back to normal heating

operation.
Do not be  alarmed  if steam  or fog  appears at  the outdoor unit  during

defrost  mode. Water  vapor  from  the melting  ice  may condense  into  a

mist in the cold outside air.
During certain weather conditions such as heavy snow and freezing rain

it is not uncommon for ice to build up on the unit grille. This is normal

for these weather conditions. Do not attempt to remove the ice from the

unit grille. This condition will not affect the proper function of the unit

and will clear within a few days.
During  defrost  mode,  your  heat  pump  will  automatically  turn  on  the

supplemental heat, if equipped. You may notice the indoor fan increase

its speed.

Emergency Heating Mode

In  the  event  of  primary  unit  heat  failure,  the  emergency  heat  mode

allows your supplemental heating  source  to keep your home or  office

warm until your unit can be serviced.  Contact your dealer in the event of

primary unit heat failure.
During Emergency Heat, your thermostat will lockout the heat pump and

turn on the supplemental heat, if equipped. You may notice the indoor

fan increase its speed.

Maintenance and Service

This  section  discusses  maintenance  that  should  be  performed by  your

dealer and care you, as the owner, may wish to handle for your new unit.

Routine Maintenance

All  routine  maintenance  should  be  handled  by  skilled,  experienced

personnel. Your dealer can help you establish a standard procedure.
To assure proper functioning of the unit, flow of condenser air must not

be obstructed from reaching the unit. Clearance from the top of the unit

is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm) is required on

sides except the power entry side (42 in. [1067 mm] clearance).

Maintenance and Care for the Equipment Owner

Before  proceeding  with  those  things  you  might  want  to  maintain

yourself, please carefully consider the following:

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and changed or

cleaned whenever it becomes dirty. Dirty filters produce excessive stress

on the blower motor and can cause the motor to overheat and shut down.
This unit must have an air filter in place before it can be operated. These

filters  should  be  located  in  at  least  one  of  two  places.  In  many

applications, the installer will provide return air filter grilles mounted on

the wall or ceiling of the conditioned structure. In the instance of filter

grilles, the filters can simply be removed from the grille and replaced.

Table 1

 indicates the correct indoor filter size for your unit. 

When installing the new filter(s), note the direction of the airflow arrows

on the filter frame.
If  you  have  difficulty  locating  your  air  filter(s)  or  have  questions

concerning  proper  filter  maintenance,  contact  your  dealer  for

instructions. When replacing filters, always use the same size and type of

filter that was supplied originally by the installer.

Fans and Fan Motor

Periodically  check  the  condition  of  fan  wheels  and  housings  and

fan-motor  shaft  bearings.  Contact  your  dealer  for  the  required  annual

maintenance.

Indoor and Outdoor Coils

Cleaning of the coils should only be done by qualified service personnel.

Contact your dealer for the required annual maintenance.

Condensate Drain

The drain pan and condensate drain line should be checked and cleaned

at the same time the cooling coils are checked by your dealer.

Compressor

All  compressors  are  hermetically  sealed  and  do  not  require  periodic

maintenance.

Condenser Fan

The fan must be kept free of all obstructions to ensure proper cooling.

Contact your dealer for any required service.

Electrical Controls and Wiring

Electrical controls are difficult to check without proper instrumentation.

If there are any discrepancies in the operating cycle, contact your local

dealer and request service.

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK, CUT 

HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

1. TURN  OFF  ELECTRICAL  POWER  TO  YOUR  UNIT

BEFORE SERVICING OR PERFORMING MAINTENANCE

AND INSTALL A LOCK-OUT TAG.

2. When  removing  access  panels  or  performing    maintenance

functions inside your unit, be aware of sharp sheet metal parts

and  screws.  Although  special  care  is  taken  to  reduce  sharp

edges to a minimum, be extremely careful when handling parts

or reaching into the unit.

Table 1 – Indoor Air Filter Data

Unit Size

Filter Size

024

20x20x1 (508x508x25 mm)

030-036

24x30x1 (610x762x25 mm)

042-060

24x36x1 (610x914x25 mm)

WARNING

!

FIRE AND UNIT OPERATION HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

Never  operate  your  unit  without filters  in place. An  accumulation of

dust and lint on internal parts of your unit can cause loss of efficiency.

WARNING

!

PERSONAL INJURY AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

Do not poke sticks, screwdrivers, or any other object into revolving fan

blades.