background image

PH4G: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

3

outside air. So, to maintain energy-efficient  operation, your unit has an

automatic defrost mode.
The defrost mode starts at a preset time interval of 60 minutes, although,

it may be reset to 30, 90 or 120 minutes. Defrost will start at the preset

time  only  if  the  ice  is  sufficient  to  interfere  with  normal  heating

operation.
After the ice is melted from the coil, or after a maximum of 10 minutes

in defrost mode, the unit automatically switches back to normal heating

operation.
Do not be  alarmed  if steam  or fog  appears at  the outdoor unit  during

defrost  mode. Water  vapor  from  the melting  ice  may condense  into  a

mist in the cold outside air.
During certain weather conditions such as heavy snow and freezing rain

it is not uncommon for ice to build up on the unit grille. This is normal

for these weather conditions. Do not attempt to remove the ice from the

unit grille. This condition will not affect the proper function of the unit

and will clear within a few days.

Emergency Heating Mode

In  the  event  of  primary  unit  heat  failure,  the  emergency  heat  mode

allows your supplemental heating  source  to keep your home or  office

warm until your unit can be serviced. Contact your dealer in the event of

primary unit heat failure.

Maintenance and Service

This  section  discusses  maintenance  that  should  be  performed by  your

dealer and care you, as the owner, may wish to handle for your new unit.

Routine Maintenance

All  routine  maintenance  should  be  handled  by  skilled,  experienced

personnel. Your dealer can help you establish a standard procedure.
To assure proper functioning of the unit, flow of condenser air must not

be obstructed from reaching the unit. Clearance from the top of the unit

is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm) is required on

sides except the power entry side (42 in. [1067 mm] clearance) and the

duct side (12  in. [305 mm] minimum clearance).

Maintenance and Care for the Equipment Owner

Before  proceeding  with  those  things  you  might  want  to  maintain

yourself, please carefully consider the following:

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and changed or

cleaned whenever it becomes dirty. Dirty filters produce excessive stress

on the blower motor and can cause the motor to overheat and shut down.
This unit must have an air filter in place before it can be operated. These

filters  should  be  located  in  at  least  one  of  two  places.  In  many

applications, the installer will provide return air filter grilles mounted on

the wall or ceiling of the conditioned structure. In the instance of filter

grilles, the filters can simply be removed from the grille and replaced.
The other typical application is an accessory filter rack installed inside

the unit itself. The following information is given to assist in changing

filters used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory installed

option. The same filter kit is included with the accessory economizers

and factory installed economizers.

To replace or inspect filters in accessory filter rack:

1. Remove  the  filter  access  panel  (See 

Fig. 3

)  using  a  5/16-in.  nut

driver.

2. Remove the filter(s) by pulling it out of the unit. If the filter(s) is

dirty, clean or replace with a new one.

When installing the new filter(s), note the direction of the airflow arrows

on the filter frame.
If  you  have  difficulty  locating  your  air  filter(s)  or  have  questions

concerning  proper  filter  maintenance,  contact  your  dealer  for

instructions. When replacing filters, always use the same size and type of

filter that was supplied originally by the installer. See 

Table 1

 for filter

sizes supplied with accessory filter rack.

A14457

Fig. 2 – Accessory Filter Rack Access Panel

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK, CUT 

HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

1. TURN OFF ELECTRICAL POWER TO YOUR UNIT BEFORE

SERVICING  OR  PERFORMING  MAINTENANCE  AND

INSTALL A LOCK-OUT TAG. THERE MAY BE MORE THAN

ONE DISCONNECT SWITCH.

2. When  removing  access  panels  or  performing    maintenance

functions inside your unit, be aware of sharp sheet metal parts and

screws. Although special care is taken to reduce sharp edges to a

minimum, be extremely careful when handling parts or reaching

into the unit.

Table 1 – Replacement Filter Sizes

Unit Size

Filter Size

24

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

30

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

42-48

1 each 24 x 14 x 1 (610 x 356 x 25 mm),

24 x 16 x 1 (610 x 406 x 25 mm)

36 & 60

*

*.Units with bent indoor coil. 

1 each 24 x 16 x 1 (610 x 406 x 25 mm),

24 x 18 x 1 (610 x 457 x 25 mm)

WARNING

!

FIRE AND UNIT OPERATION HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

Never  operate  your  unit  without filters  in place. An  accumulation of

dust and lint on internal parts of your unit can cause loss of efficiency.

Access Panels

Filter Access Panel 
For Accessory Filter Rack

Reviews: