background image

 

 
 

 

Operation and Maintenance Manual 

NOTE: 

Read all instructions and data in this manual before operating. 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

Fig. 1 – FN1SXF 

 

A Note About Safety 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

About the Negative Air Machine/Air Scrubber 

The  OptiClean™  is  a  portable  solution  primarily  designed  to  help 
convert normal hospital rooms into Airborne Infectious Isolation Rooms 
(AIIR). Designed to ASHRAE’s Standard 170 for Ventilation of Health 
Care Facilities, the OptiClean™ uses highly efficient filters and a heavy 
duty, to remove contaminated air from the room. The resulting negative 
air  pressure,  or  “vacuum  effect,”  helps  limit  the  spread  of  air-based 
contaminants into surrounding areas. 

If  negative  pressure  is  not  required,  such  as  in  an  open-air  temporary 
hospital, business or home, the machine can be used as an air “scrubber,” 
pulling air in, removing many contaminants, and discharging cleaner air 

Any  time  you  see this  symbol   

  in  manuals,  instructions and  on  the 

unit, be aware of the potential for personal injury. There are three levels 
of precaution: 

DANGER 

identifies the most serious hazards which will result in severe 

personal injury or death. 

WARNING 

signifies  hazards  that  could  result  in  personal  injury  or 

death. 

CAUTION 

is  used  to  identify  unsafe  practices  which  would  result  in 

minor personal injury or product and property damage. 

NOTE 

is  used  to  highlight  suggestions  which  will  result  in  enhanced 

installation, reliability, or operation. 

  back into the room. 

The OptiClean™ negative air machine features: 

 

99.97% efficient long-life HEPA filter removes particles as small as 
0.3 microns 

 

Standard MERV 7 pre-filter 

 

Nominal 500 CFM  

 

According to ASHRAE Standard 170: Ventilation of Health Care 
Facilities 

 

Portable and adaptable to nearly any location 

 

Heavy duty locking casters for easy and smooth transport 

 

HEPA filter rack and sealing design meet air leakage requirement 

 

Red lighted indicator to alert user when filters are overloaded 
(generally means pre-filter requires replacement) 

 

Green ON/OFF switch illuminates to verify when running 

 

3 meters long power cord with strain relief 

 

Power cable access from rear of the unit, with optional plug 

 

230V / 1Ph - 50 / 60Hz 

 

Galvanized steel, powder paint cabinet is fully insulated 

 

Exhaust transition plate to standard 

 

FN1SXF 
OptiClean™ Negative Air Machine and Scrubber 

WARNING

 

PERSONAL INJURY OR PROPERTY DAMAGE 

HAZARD 

Failure  to  follow  this  warning  could  result  in  personal  injury  or 
property damage. 
Improper  installation,  adjustment,  alteration,  service,  maintenance,  or 
use can cause conditions which may cause personal injury or property 
damage. Consult a qualified installer or your distributor for information 
or assistance. Read and follow all instructions and warnings, including 
labels shipped with or attached to unit before operating. 

WARNING

 

PORTABLE UNIT AND METAL SHARP EDGES 

HAZARD 

Failure to follow this Warning could cause personal injury or death. 
This unit must be used in a location where unsupervised children are 
not allowed to play. The unit is portable, and areas inside and under the 
unit could cause personal injury. If the unit is used in a horizontal 
configuration, physical barriers must be installed around the unit to 
prevent unauthorized access. 

WARNING

 

ELECTRICAL SHOCK HAZARD 

Failure to follow this warning could result in personal injury or death. 
Disconnect all electrical power to the unit before removing access 
panels to perform any maintenance. 

If the supply cord is damaged, it must be replaced by the manufacturer, 
its service agent or similarly qualified persons in order to avoid a 
hazard. 

WARNING

 

PERSONAL PROTECTION 

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 

Summary of Contents for OptiClean FN1SXF

Page 1: ...ment Red lighted indicator to alert user when filters are overloaded generally means pre filter requiresreplacement Green ON OFF switch illuminates to verify when running 3 meters long power cord with strain relief Power cable access from rear of the unit with optional plug 230V 1Ph 50 60Hz Galvanized steel powder paint cabinet is fully insulated Exhaust transition plate to standard FN1SXF OptiCle...

Page 2: ...lled even if the unit is being used as an air scrubber 5 Carefully lift the unit to a vertical position on its casters HINT Lock the castersbefore lifting or tilting up the unit 6 Move the unit in its final position and lock all four casters 7 For negative air setup do these steps If used as an air scrubber skip to step 8 a Use a compression clamp to attach roundflexible ducting supplied by others...

Page 3: ... new HEPA filter into the unit with the gasket on the filter facing up on the discharge side of the filter Make sure the HEPA filter is centered and the edges align with the brackets on the top side and each side for a completeseal 9 Re install the bottom supports and attach the bottomnuts 10 Tighten the nuts equally until the filter is held securely in place and ensure the top HEPA filter gasket ...

Page 4: ...d in to a working electrical outlet Check for sufficient airflow Filters should be clean and unobstructed If you need to contact your authorized dealer for troubleshooting and or repairs be sure to have the model and serial numbers of your equipment available Specifications Filter Type Efficiency Size Filter Part No Pre filter MERV 7 16 x 20 x 2 KH 12AF 110 S HEPA Filter H13 16 x 20 x 12 KH 12AP 1...

Reviews: