6-3
62-11848
6.2.3
Unit Operates Long or Continuously in Cooling
Box
Hot Load
Insufficient pull
down time
Defective box insulation or air leak
Correct
Refrigeration system
Abnormal pressure
Temperature controller malfunction
Compressor
Defective
Replace
6.2.4
Unit Will Not Heat or Heating Insufficient
Refrigeration
Abnormal pressure
Temperature controller malfunction
Hot gas solenoid malfunction
Compressor
Compressor drive (clutch) defective
Check
Compressor defective
Replace
6.2.5
Defrost Malfunction
Automatic defrost will not
initiate
Defrost thermostat (DTT) open or defective
Replace
Hot gas solenoid valve malfunction
Defrost disabled through cab command
Manual defrost will not initiate
Microprocessor defective
Replace
Defrost thermostat (DTT) open or defective
Replace
Defrost cycle initiates but does
not defrost
Hot gas solenoid malfunction
Condenser Pressure Control valve malfunction
Frequent defrost
Wet load
--
Defrost settings set too low.
Does not terminate or cycles on
defrost
Defrost thermostats (DTT) shorted closed
Replace
6.2.6
Abnormal Pressure
Cooling:
High discharge pressure
Condenser coil dirty
Non-condensables in system
Refrigerant overcharge
Condenser fan/motor defective
Replace motor
Low discharge pressure
Compressor defective
Replace
Hot gas solenoid malfunction
Low refrigerant charge
High suction pressure
Compressor defective
Replace
Hot gas solenoid malfunction
Compressor pressure regulator mis-adjusted (CPR)
Table 6–2 Mechanical Indications
INDICATION / TROUBLE
POSSIBLE CAUSES
REFERENCE
SECTION