background image

7

ACCESSORIES

CONTROLS:

THERMOSTATS

AND ZONING

A97432

ENERGY/HEAT

RECOVERY

VENTILATOR

A94336

HUMIDIFIER

A91365

Available in programmable

and non---programmable

models, Carrier thermostats

maintain a constant, com-

fortable temperature level in

the home.

For the ultimate in home

comfort, Carrier’s 2, 4, and

8---zone systems allow tem-

perature control of individu-

al “zones” of the home.

This is accomplished

through a series of elec-

tronic dampers and remote

room sensors. The 4---zone

system is shown.

Carrier’s energy or heat recov-

ery ventilators exhaust stale in-

door air and provide fresh out-

door air to the home while mini-

mizing heat loss and humidity

level. Especially useful for

today’s tighter constructed

houses.

Energy recovery ventilator is

shown.

ELECTRONIC OR

MECHANICAL

AIR CLEANER

A97380

Cleans the air of smoke, dirt,

and many pollens commonly

found. Saves decorating and

cleaning expenses by keeping

carpets, furniture, and drapes

cleaner.

Electronic air cleaner is

shown.

By adding moisture to winter---dry air,

Carrier humidifier can often improve

comfort and keeps woodwork, wall-

paper, and paint in better condition.

Moisturizing household air also helps

to retain normal body heat and pro-

vides comfort at lower temperatures.

®

FURNACE ACCESSORIES

KLABV0201DET

Blocked Vent Shutoff Kit

HYBRID HEAT/THERMIDISTAT CONTROL

TSTATCCPHH01---B

Hybrid Heat Thermostat, Programmable, Outdoor Temperature Sensor Included

PROGRAMMABLE THERMOSTAT SELECTION

TSTATCCPAC01---B

Thermostat, Auto Changeover, 7---Day Programmable,

°

F/

°

C, 1---Stage Heat/1---Stage Cool

TSTATCCPHP01---B

Thermostat, Auto Changeover, 7---Day Programmable,

°

F/

°

C, 2---Stage Heat/1---Stage Cool

TSTATCCP2S01---B

Thermostat, Auto Changeover, 7---Day Programmable,

°

F/

°

C, 2---Stage Heat/2---Stage Cool in AC, 3---Stage

Heat/2---Stage Cool in HP mode

TSTATCCPRF01

Thermostat, Auto Changeover, 7---Day Programmable,

°

F/

°

C, Wireless Transmitter

TSTATCCPF701

Thermostat, Auto Changeover, 7---Day Programmable,

°

F/

°

C, Flatstat

NON---PROGRAMMABLE THERMOSTAT SELECTION

TSTATCCNAC01---C

Thermostat, Auto Changeover, Non---Programmable,

°

F/

°

C, 1---Stage Heat/1---Stage Cool

TSTATCCNHP01---C

Thermostat, Auto Changeover, Non---Programmable,

°

F/

°

C, 2---Stage Heat/1---Stage Cool

TSTATCCN2S01---C

Thermostat, Auto Changeover, Non---Programmable,

°

F/

°

C, 2---Stage Heat/2---Stage Cool in AC, 3---Stage

Heat/2---Stage Cool in HP mode

ZONING CONTROL SELECTION

ZONECC2KIT01---B

Comfort Zone II---B --- 2 Zone Kit/Temperature and Humidity Control

ZONECC4KIT01---B

Comfort Zone II---B --- 4 Zone Kit/Temperature and Humidity Control

ZONECC8KIT01---B

Comfort Zone II---B --- 8 Zone Kit/Temperature and Humidity Control

HEALTHY HOME SOLUTIONS

EACBAXCC0014

Electronic Air Cleaner --- 120V, 1400 CFM

EACBAXCC0020

Electronic Air Cleaner --- 120V, 2000 CFM

EACBAXCC2020

Electronic Air Cleaner --- 240V, 2000 CFM

HUMCCSBP2312

Humidifier --- 12 g./day, 24V Standard, Small Bypass

HUMCASBP2312

Humidifier --- 12 g./day, 24V Automatic, Small Bypass

HUMCCLBP2317

Humidifier --- 17 g./day, 24V Standard, Large Bypass

HUMCALBP2317

Humidifier --- 17 g./day, 24V Automatic, Large Bypass

HUMCCLFP1318

Humidifier --- 18 g./day, 24V Standard, Fan Powered

HUMCALFP1318

Humidifier --- 18 g./day, 24V Automatic, Fan Powered

HRVCCSHA1100

Heat Recovery Ventilator --- Small Horizontal Unit, 100 CFM

HRVCCSVA1100

Heat Recovery Ventilator --- Small Vertical Unit, 100 CFM

HRVCCLHA1150

Heat Recovery Ventilator --- Large Horizontal Unit, 150 CFM

HRVCCLHA1250

Heat Recovery Ventilator --- Large Horizontal Unit, 250 CFM

HRVCCSVU1150

Heat Recovery Ventilator --- Small Vertical Unit, 150 CFM

HRVCCSVU1200

Heat Recovery Ventilator --- Small Vertical Unit, 200 CFM

HRVCCLVU1150

Heat Recovery Ventilator --- Large Vertical Unit, 150 CFM

HRVCCLVU1200

Heat Recovery Ventilator --- Large Vertical Unit, 200 CFM

HRVCCLVU1330

Heat Recovery Ventilator --- Large Vertical Unit, 330 CFM

ERVCCSHA1100

Energy Recovery Ventilator --- Small Horizontal Unit, 100 CFM

Summary of Contents for Low-Boy 58CLR

Page 1: ...d provide reliable operation and easy connection of thermostat and accessory wiring Casing S Made of 18 gauge painted steel for years of durability S Cabinet features an insulated enclosure for the burner and controls Insulation and Soundproofing S Unique sound trap along with insulated walls efficiently capture most combustion noise and vibration make this unit one of the quietest on the market S...

Page 2: ... 3 3 H U M 4 5 6 N 7 2 S E A C C O N T C O O L H E A T C X G W R Y C ON 1 2 MODEL NUMBER NOMENCLATURE 58CLR 105 120 12 Riello Burner Low Boy Oil Furnace Series Cooling Size Airflow Nominal 400 CFM per 12 000 Btuh Cooling 12 1200 CFM Input Capacity 105 70 000 Btuh with 0 40 gph nozzle 91 000 Btuh with 0 50 gph nozzle 105 000 Btuh with 0 65 gph nozzle 120 119 000 Btuh with 0 75 gph nozzle 140 000 Bt...

Page 3: ...at exchanger designed and shaped to efficiently transfer heat from furnace into the home 8 Supply air plenum 9 Fully insulated internal walls to minimize heat loss 10 High limit control to prevent overtemperature 11 Manual switch to allow user control of constant low speed blower operation 12 Adjustable electronic fan timer control inside has low voltage electrical terminal strip for easy connecti...

Page 4: ... 115 000 126 000 NOZZLE 0 40 70A 0 50 70W 0 65 70W 0 75 70B 0 85 70W 1 00 70W FIRING RATE GPH 0 50 0 65 0 75 0 85 1 00 1 10 AFUE 80 5 80 5 80 5 80 0 80 0 80 0 OIL PUMP STAGES PRESSURE PSIG 1 160 1 170 1 135 1 130 1 140 1 125 HEATING TEMP RISE _F 55 85 55 85 55 85 55 85 55 85 55 85 COOLING CFM 0 5 IN WC STATIC PRESSURE 1250 1250 1250 1865 1865 1865 HEATING CFM 0 2 IN WC STATIC PRESSURE 840 1130 142...

Page 5: ... 1865 1700 1575 1475 1335 Med High 1890 1860 1770 1675 1550 1450 1330 1215 Med Low 1555 1475 1395 1320 1210 1135 1050 940 Low 1220 1165 1080 1000 925 855 780 655 ELECTRICAL DATA UNIT SIZE 105 12 120 20 UNIT VOLTS HERTZ PHASE 115 60 1 115 60 1 OPERATING VOLTAGE RANGE Min Max 104 132 104 132 MAXIMUM UNIT AMPS 12 2 15 7 MINIMUM WIRE SIZE AWG 14 12 MAXIMUM WIRE LENGTH Ft 26 26 MAXIMUM FUSE SIZE OR CKT...

Page 6: ... 20 20 VENT CONN A98009 DIMENSIONS IN UNIT SIZE UNIT DIMENSIONS FLUE HEIGHT RETURN OPENING SUPPLY OPENING VENT CONN WIDTH DEPTH HEIGHT A B C D E 105 12 21 1 4 53 3 4 31 1 2 26 1 2 20 20 5 120 20 21 1 4 60 5 32 34 3 4 28 11 32 22 24 6 58CLR ...

Page 7: ...CPRF01 Thermostat Auto Changeover 7 Day Programmable F C Wireless Transmitter TSTATCCPF701 Thermostat Auto Changeover 7 Day Programmable F C Flatstat NON PROGRAMMABLE THERMOSTAT SELECTION TSTATCCNAC01 C Thermostat Auto Changeover Non Programmable F C 1 Stage Heat 1 Stage Cool TSTATCCNHP01 C Thermostat Auto Changeover Non Programmable F C 2 Stage Heat 1 Stage Cool TSTATCCN2S01 C Thermostat Auto Cha...

Page 8: ... EZXCABCC1020 Media Filter Cabinet 2000 CFM Replacement Filter EXPXXFIL0020 TYPICAL INSTALLATION OIL TANK FLUE PIPE A C COIL SUPPLY AIR DUCT AIR CONDITIONER OR HEAT PUMP AIR FLOW RETURN AIR DUCT LOW BOY OIL FURNACE CHIMNEY A98010 Copyright 2007 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and...

Reviews: