background image

 © 2021 Carrier. All rights reserved.

A Carrier Company 

Edition Date: 5/21

Catalog No: OM-KVACN-AC-01

Replaces: New

KVACN0101(B,C)AC: Installation and User Guide

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

7. Perform the electrical connection to the terminal connector of the

unit,  as  shown  below.  For  more  details,  refer  to  the  installation

manual of the ventilation unit.

NOTE: 

To avoid miswiring, refer to the notes taken at step 5 to match

the wire color with the right terminal.

A200533

8. Plug the ventilation unit and test the wall control.

HOW TO USE THE CONTROL

A200534

The main button works following this sequence: 
Click 1 = RECIRC (if available)
Click 2 = INT
Click 3 = MIN
Click 4 = MED
Click 5 = MAX
Click 6 = OFF
and so on

The indicator lights up per the selected mode.

RECIRC

—Recirculate  air  inside  the  house  at  MAX  speed.  Not

available on all units.

INT

—Within a one hour period, the system will operate in MIN speed

for 20 minutes.

MIN/MED/MAX

—Continuous exchange ventilation at selected speed.

• Press the TURBO button to get 4 hours of ventilation in MAX speed.

The TURBO indicator will light up. Once the 4-hour period is done,

the system will operate according to the previous setting.

• Press the AUTO button to let the system operate according to outdoor

temperature. The AUTO indicator will light up. The AUTO indicator

will light up and the system will operate as follows:

• Less than -25°C (-13°F) = 10 min/hr
• -25°C (-13°F) to -7°C (19°F) = 20 min/hr
• -7°C (19°F) to 10°C (50°F) = 40 min/hr
• 10°C (50°F) TO 25°C (77°F) = MIN speed
• 25°C (77°F) to 28°C (82°F) = 30 min/hr
• 28°C (82°F) to 33°C (91°F) = 20 min/hr
• Above 33°C (91°F) = 10 min/hr

• If the maintenance indicator is lit, it means that the filter needs to be

cleaned or replaced. Once the filter is cleaned or replaced, press the

AUTO button for five seconds to reset the maintenance indicator. If

the  maintenance  indicator  flashes,  the  LCD  screen  on  the  unit  will

give  the  error  code.  Refer  to  the  Troubleshooting  section  in  the

ventilation unit user guide for more information.

• At unit first boot, AUTO and TURBO indicators blink alternately for

about  1  minute.  If  indicators  continue  blinking  after  this  period,  it

means  that  the  communication  cannot  be  established  with  the

ventilation unit. Make sure wires are correctly connected to the wall

control and unit terminals (refer to step 7).