This kit may be used to replace labels that are upside--down when the furnace is installed in the Downflow position. Only the labels that are
upside--down when the outer door and blower access door is installed are included in this kit. The unit rating plate is NOT included in this kit.

The unit rating plate is unique to each furnace and is not considered a service item.
Use the following tables to determine the correct label for the following furnaces:

STANDARD MODEL

DELUXE MODEL

2---SPEED MODEL

VARIABLE SPEED MODEL

Label Number

58STA/STX

58DLA/DLX

58PHA/PHX

58CTA/CTX

58CVA/CVX

327558---101

X

X

X

X

336996---101

X

X

X

X

337801---201

X

X

N/A

N/A

337802---201

N/A

N/A

X

N/A

337803---201

N/A

N/A

N/A

X

X--- Label used

STANDARD MODEL

DELUXE MODEL

2---SPEED MODEL

VARIABLE SPEED MODEL

Label Number

310AAV/JAV

311AAV/JAV

313AAV/313JAV

312AAV/JAV

315AAV/JAV

327558---101

X

X

X

X

336996---101

X

X

X

X

337801---201

X

X

N/A

N/A

337802---201

N/A

N/A

X

N/A

337803---201

N/A

N/A

N/A

X

X--- Label used

STANDARD MODEL

DELUXE MODEL

VARIABLE SPEED MODEL

Label Number

PG8MAA/PG8JAA

PG8MEA/PG8JEA

PG8MVA/PG8JVA

327558---101

X

X

X

336996---101

X

X

X

337801---201

X

X

N/A

337802---201

N/A

N/A

N/A

337803---201

N/A

N/A

X

X--- Label used

APPLY THE CORRECT LABELS

1. From the unit rating plate and the tables above, determine the correct labels required.
2. Turn off electrical power to furnace at service switch, fuse, or circuit breaker.
3. Remove outer door and blower access door.
4. It is not necessary to remove old labels from doors. However, doors must be dry and free of dust, dirt, grease and oil. If necessary,

clean old label surfaces with household glass or surface cleaners.

5. Remove the paper backing from the appropriate label.
6. Orient the label in the correct position and apply over the surface of the old label. Prevent air bubbles in the new label by applying the

label at one corner and smooth the label out, working toward the opposite corner.

7. Repeat for the other labels.
8. Re--install the blower access door and unit outer door.
9. Turn on electrical power to furnace.

10. Check furnace for correct operation (refer to furnace Installation Instructions.)