Summary of Contents for Infinity SYSTXCCUID01-A

Page 1: ... Section i Check Equipment Jobsite 2 Section 2 Infinity Control Location and Wiring Considerations 2 4 Section 3 Installing Infinitv Control 5 6 Initial Power Up 7 8 Section 1 Powerup Sequence 7 Section 2 Selecting Outdoor Unit 7 Section 3 Selecting Electric Heater 7 Section 4 Selecting Accessories 7 8 Section 5 Equipment Summary 8 Section 6 Static Pressure Check 8 Quick Start 9 Install Service Me...

Page 2: ... to connecting the system components and commissioning the system once all physical components are installed Special screen prompts and start up capabilities are provided in the Infinity System to simplify and automate the initial commissioning of the system Install Infinity Control according to this instruction Install indoor unit outdoor unit and accessories ac cording to their instructions Wire...

Page 3: ...block can be mounted directly to the wall by cutting a hole 1 1 2 wide by 2 1 8 high Mark location and cut hole in wall NOTE Always ensure the Infinity Control location is acceptable before cutting any holes in wall SURFACE MOUNT This provides surface mounting configuration which allows use of a small hole in the wall A surface mount backplate is supplied See Fig 4 Attach backplate as shown in Fig...

Page 4: ...ackpiate to wall Interlocking Tabs 4 Fig 7 Surface Mount Assembly Fig 8 Large Decorative Backplate A03191 A03188 _ _ _ Recessed terminal block _ LJlJ 2n1 w_ ll_ilh 2 wide bY _ _ _Recessed Mount l_Llnterlocking Tabs 4 Fig 6 Recessed Mount Assembly A03190 Fig 9 Decorative Backplate Assembly A03192 ...

Page 5: ...ting to furnace or fan coil Ensure connector is inserted properly into circuit board See Fig 10 A03193 Fig 10 Wire ABCD Connector ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation Improper wiring of the ABCD connector will cause the Infinity System to operate improperly Check to make sure all wiring is correct before proceeding with ins...

Page 6: ...l HUM and 24vac COM terminals The Infinity Control will automatically energize the HUM output during a call for humidification FAN POWERED HUMIDIFIERS Most fan powered humidifiers produce internal 24vac in order to energize upon a switch or contact closure For this application a 24vac N O Isolation Relay DPST MUST be used to prevent mixing the internal humidifier power with the indoor equipment tr...

Page 7: ...o select appropriate Btu size of outdoor unit then press right side button to continue If a NIM Network Interface Module is applied for non communicating two stage outdoor equipment select 1 or 2 stage compressor operation and press right side button to continue NOTE Range of outdoor unit Btu selection is limited by model number of indoor unit installed The Infinity Control will not allow an outdo...

Page 8: ...MPLETE SAVE ALL SELECTIONS screen will appear after Equipment Summary To Save All Selections press YES right side button Pressing the left side button NO selection will return to the Equipment Summary screen where changes can be performed to any of the equipment selection screens After selecting YES the initial power up sequence of the new Infinity Control is complete SECTION STATIC PRESSURE CHECK...

Page 9: ...orarily overriding the temperature schedule is 2 00 HRS as indicated by the text on the lower left NOTE Override time will not appear if programming has been turned off 4 You can change the temporary override time in 15 minute increments by pressing the TIME button until the desired override time is selected or press the HOLD button anytime to override the schedule indefinitely QUICK PROGRAM SCHED...

Page 10: ...type and model number if a z stage unit filter type and any accessories that are installed are recognized INSTALL TO ADD UNINSTALL OR RE INSTALL EQUIPMENT PRESS RIGHT SIDE SUTTON BACK INSTALL A03202 Fig 23 INSTALL This menu item will perform start up process in order to learn all equipment in system Press right side button to initiate the process See Fig 23 SETUP MENU SETUP THERMOSTAT FURNACE HEAT...

Page 11: ...ettings will be copied to the furnace setup menu Any changes can then be made from the Infinity Control AIRFLOW COMFORT default EFFICIENCY Selects the airflow of the furnace when heating EFFICIENCY is the airflow used to meet specified ratings COMFORT is a decreased airflow used to increase the output air temperature and provide increased comfort AC AIRFLOW COMFORT default cooling airflow is varie...

Page 12: ...the start up process This value can be changed to another value limited by the model number of the fan coil If the electric heater is self identifying this value is not shown SETUP HEAT PUMP AC COOLING LOCKOUT NONE default 45 F 50 E 55 E Outside temperature below which cooling will not be provided LOW AMBIENT COOLING NO default YES Selecting YES will enable the low ambient cooling operation in the...

Page 13: ...actual operation default 90 Interval at which the Clean Ventilator Pre filter notification will turn on UV LIGHTS INSTALLED NO YES If YES indicates to the system whether UV lights are installed CHANGE INTERVAL 6 to 48 months operation time default 12 months Interval at which the Change UV Lights notification will be displayed SETUP SYSTEM MAINTENANCE REMIND OWNER OF ROUTINE MAINTENANCE EVERY This ...

Page 14: ...st cycle is also selectable Default time Fixed 5 min minimum range 5 120 min NOTE Airflows during Checkout modes are fixed to the Efficiency setting and are independent of other airflow settings To view airflows for normal heat pump heating mode exit the Checkout screen and apply a heating demand to the system CHECKOUT HEAT PUMP COOLING OR AC COOLING HIGH COOL RUNTIME 5 min LOW COOL RUNTIME 5 min ...

Page 15: ...r is active this will show the current time value See furnace manual for details on lockout timers SERVICE FAN OIL STATUS ELECTRIC HEAT OFF LOW MED HIGH Displays stages of electric heat that the fan coil is currently delivering AIRFLOW CFM fan coil model number dependent Cubic Feet per Minute of air the blower is currently delivering LEAVING AIR TEMP This sensor is NOT required However if LAT sens...

Page 16: ...sing FAN button will scroll through the following AUTO No fan operation except during equipment operation LOW Approximately 50 of High Speed operation MED Half way between High and Low speed operation HIGH Highest of either High Heating or High Cooling CFM Continuous fan operation is programmable The programming option must be enabled in the Thermostat Setup See the Homeowner s Manual for detailed...

Page 17: ...fore one hour has elapsed it will resume cooling operation After one hour cooling will be resumed DEHUMIDIFY OPERATION Once a target cooling humidity set point is selected in the Advanced Setup COOLING HUMIDITY screen two other setup options affect Dehumidify operation AC AIRFLOW and DEHUMIDIFY AC AIRFLOW This setting is located in the Furnace or Fan Coil Setup screens and must be set to COMFORT t...

Page 18: ...erminal 3 Press left side button to try again 4 If display still reads Indoor Unit Not Found disconnect all devices from ABCD and connect User Interface directly to indoor unit Display says Outdoor Unit Not Found and I have a two stage communicating outdoor unit 1 Recheck wiring to ABCD connector on outdoor unit 2 Make sure all colors match for ever 5 terminal 3 Check for 24VAC between the C and D...

Page 19: ...rror code is cleared or disappears furnace heating will resume if still requested OUTDOOR UNIT Code 25 Invalid model plug Code 45 Control Failure Code 47 No 230V at unit Code 73 Contactor shorted Code 74 No high voltage at compressor Code 76 Low stage didn t start three times Code 78 High stage didn t start three times Code 81 Thermal lockout in low stage 4 hrs Code 82 Thermal lockout in high stag...