background image

SYSTXCCITC01---B

Infinity

r

System Control

Owner’s Manual

A170203

NOTE

: Read the entire instruction manual before starting the installation.

The features and functions outlined in this Owner’s Manual reflect Version 1.3 or

later software. Occupancy sensing is only available with Series B Infinity System
Controls. See the Downloads section of www.MyInfinityTouch.Carrier.com for the

latest software release and literature.
US Patents: Carrier

r

U.S. Pat No. 7,243,004, Carrier

r

U.S. Pat No. 7,775,452,

pointSET

t

U.S. Pat No. 7,415,102

Summary of Contents for INFINITY SYSTXCCITC01

Page 1: ...ons outlined in this Owner s Manual reflect Version 1 3 or later software Occupancy sensing is only available with Series B Infinity System Controls See the Downloads section of www MyInfinityTouch Ca...

Page 2: ......

Page 3: ...me 6 Adjust Temperature Temporary Hold 6 Adjusting Comfort Activities 7 Adjusting Heating 7 Adjusting Cooling 8 Adjust Temperature Permanent Hold 8 Adjusting Comfort Profiles 8 Adjusting Heating 9 Adj...

Page 4: ...20 Vacation Fresh Air Control 21 SCHEDULES 22 View or Edit Schedule 23 Guided Scheduling 24 Upload My Schedule 26 VACATION 28 REMINDERS 30 OPERATING STATUS 31 Accessories Status 32 Temperature Contro...

Page 5: ...e Zone 42 Enable Time Synchronization 42 SERVICE 43 Service Information 43 Service Reminder Update 44 Software Update 44 Updating Software Using Micro SD Card 45 Updating Software Using Wi Fi 47 Model...

Page 6: ...59 UTILITY DEMAND EVENT RESPONSE SETUP 62 Utility Event 62 Price Response 63 Price Settings 63 Demand Response 64 Demand Settings 65 Response Limits 65 Restore UE Factory Default Settings 66 STATEMEN...

Page 7: ...ation The information displayed on the home screen will appear when there has been no interaction with the Infinity System Control for at least two minutes The basic information displayed on the Home...

Page 8: ...me Wi Fi network and MyInfinity Server is displayed in the top right hand corner of the Home Screen When the Infinity System Control is connected to the home Wi Fi network and the MyInfinity Server th...

Page 9: ...will appear over the strength bars If the Infinity System Control is connected to the home Wi Fi network but loses con nection to the MyInfinity Server a triangle will appear over the strength bars a...

Page 10: ...the Remote Access Status screen A13262C Information Buttons On the bottom of some screens will be an information icon By pressing the information icon a text box will display to show what interactions...

Page 11: ...or fan S If AUTO is selected the Infinity System Control automatically switches between heating and cooling to maintain your comfort during transition al seasons NOTE AUTO mode is intended to switch b...

Page 12: ...t the top middle of the screen or access by going through the menu screen see Pg 40 S To set the HOUR MINUTE MONTH DAY or YEAR touch the fea ture you wish to change S Use the Up Y and Down B buttons t...

Page 13: ...d Fan Only will not be available When changing from the OFF mode to Heat Cool Auto or Fan Only it is normal for the system to run the blower for a minute or two During this time the system is using th...

Page 14: ...rements S When the correct time interval is displayed touch DONE S To return to the scheduled program touch HOLD UNTIL and then select PER SCHEDULE Adjust Temperature Permanent Hold The Infinity Syste...

Page 15: ...Cooling S To adjust the cooling temperature enter the Main Screen by touching anywhere on the Control S With the system in either AUTO or COOL mode use the Up Y and Down B buttons to set the desired t...

Page 16: ...d schedule A14239 d Selecting the HOLD option will permanently override your pro grammed schedule until you CANCEL ALL ZONES d Selecting the HOLD UNTIL option will allow you to temporarily override yo...

Page 17: ...cupancy Sensing feature is enabled the current scheduled activity is HOME or WAKE and timing is per schedule the activity and set point s change to AWAY automatically when the space is determined to b...

Page 18: ...rofile If the current activity is Manual it will only change the current fan speed S For zoned systems the selected fan speed and Comfort Profile changes will apply to the zone currently displayed in...

Page 19: ...roduct to the Internet Comfort Profiles You will need to set the comfort profiles before you attempt to program your new Infinity System Control S The COMFORT PROFILES button includes settings for Tem...

Page 20: ...tem to dynamically deter mine the away temperature automatically to save the most amount of money yet reach your comfort settings when you return home Advanced Smart Setback may Control the temperatur...

Page 21: ...sh air if applicable using the HU MIDITY AND FRESH AIR PROFILES for each activity A14242 Home Comfort Profile Humidity Control S Touch WHEN AT HOME to set your humidity settings while the home is occu...

Page 22: ...ave the option to turn ON or OFF your humidifier from this screen A14244 d Once your Humidifier is turned ON use the Up Y and Down B buttons to set the desired humidity level between 5 45 d Press SAVE...

Page 23: ...talled in your home select the amount of fresh air to circulate during heating mode by touching Heating Fresh Air NOTE This option may not be available with the ERVXXNVA ventilator due to its simplifi...

Page 24: ...hen finished or CANCEL to discard any changes S If applicable next select the amount of fresh air to circulate during cool ing mode by touching COOLING FRESH AIR Again you will have the option of choo...

Page 25: ...ch YES or NO for the system to over cool the conditioned space by up to 3_ F to remove as much humidity out of the air as possible d Press SAVE when finished or CANCEL to discard any changes Away Comf...

Page 26: ...hed or CANCEL to discard any changes S If applicable select the amount of fresh air to circulate during cooling mode by touching COOLING FRESH AIR Again you will have the option of choosing among AUTO...

Page 27: ...HUMIDITY d Use the Up Y and Down B buttons to set the maximum dehu midification level at NONE or between 55 65 d Touch YES or NO for the system to over cool the conditioned space by up to 3_ F to rem...

Page 28: ...e percentage of fresh air to supply to your home d Use the Up Y and Down B buttons to set the desired ventilation level d Press SAVE when finished or CANCEL to discard any changes S If applicable sele...

Page 29: ...ction for more details on connecting your product to the Internet A14249 View or Edit Schedule S To set a specific day use the Left A and Right buttons beside the day names d If you wish to copy this...

Page 30: ...ith your comfort settings proceed to the next screen If you are not go through the process outlined under Comfort Profiles Pg 13 1 If you have a zoning system the next question will prompt you to pick...

Page 31: ...teps the next question will ask if you want different sleep settings S If you select YES the next question will ask what time you go to sleep d Use the Up Y and Down B buttons to set the time you go t...

Page 32: ...ice and upload the schedules into the Infinity System Control NOTE Use a 4GB to 32GB micro SD memory card The card should be formatted for FAT32 rather than FAT64 in order to be read by the control S...

Page 33: ...ule file in the User folder on the micro SD card d Once that is complete safely remove the micro SD card from the computer S Install the micro SD card into the micro SD card slot on the bottom of the...

Page 34: ...set a prolonged vacation schedule A12174 S Touch PLAN VACATION to begin your vacation schedule S The system automatically selects to start vacation at the current time S Use the Up Y and Down B butto...

Page 35: ...from your vacation then touch NEXT The system won t allow you to select a vacation end time that would result in a vacation duration of less than one day S Review your vacation schedule to make sure i...

Page 36: ...re accessory messages to remind you when it is time for maintenance Select the REMINDERS icon from the menu screen A12123 S You have the option of choosing a pop up reminder for your air filter humidi...

Page 37: ...following messages A160190 Within the operating status you can view which function your system is performing and at which stage the heating or cooling equipment is operating A message stating System C...

Page 38: ...l temperatures and temperature set points for each zone in your system S When you are done looking at your zone status press DONE The system will indicate which mode is running by showing flashing arr...

Page 39: ...33 system will show a single arrow towards either the heating or cooling set point for each zone pending conditioning in the other mode A160187...

Page 40: ...34 DISPLAY The following display preferences can be adjusted for Infinity System Control Temperature Units F or C Backlight Levels Sound Settings and Screen Saver Settings A14256...

Page 41: ...ion for Fahrenheit A14257 Set Backlight Levels S Backlight levels are programmable for each Comfort Profile setting HOME AWAY WAKE or SLEEP S Use the Up Y and Down B buttons to set change the brightne...

Page 42: ...n emit a click sound in response to each screen touch Select ENABLED to turn this sound on or DISABLED to turn it off A14259 Screen Saver Settings To allow a photo to act as a screen saver touch ENABL...

Page 43: ...l lock the screen and take you back to the home screen A13247 S To unlock the screen press and hold UNLOCK in the bottom left hand corner for 10 seconds A13248 S The screen will change and the Control...

Page 44: ...nd this section does not apply A12111 S Touch VIEW ENERGY USAGE to view the estimated energy con sumption in daily monthly or annual time intervals You can view ener gy consumption in units kWh for el...

Page 45: ...39 d Use the Up Y and Down B buttons to set the costs per kWh and cost per Therm or your selected unit d Once the correct pricing is entered press SAVE A12113...

Page 46: ...ually or can be synchronized with the web server only for Wi Fi enabled units From the Main Screen touch MENU on the bottom of the Control The TIME DATE icon will bring up the time and date menu Manua...

Page 47: ...ou have completed all of the settings touch SAVE Setup Daylight Savings Time You can program your Infinity System Control to automatically adjust for daylight saving time From this screen you can also...

Page 48: ...Then select the time zone for the location Time zones for both US and Canada are included A14217 Enable Time Synchronization For systems with Wi Fi capability after setting up the time zone the time s...

Page 49: ...r your wall Control A170237C Service Information Your dealer information is easily accessible and may already be pre programmed in your Control by your dealer Select the SERVICE INFORMATION option S E...

Page 50: ...f these reminders 3 to 18 months A13251 Software Update Carrier will periodically issue software updates for the Infinity System Control Updates will download automatically through your Wi Fi connecti...

Page 51: ...GB in size Your micro SD card must be formatted as FAT32 S From the downloads page on the MyInfinity website click on the link under the Download Latest Software S Read the End User License Agreement...

Page 52: ...s complete the TSTAT folder will appear on the root directory of the micro SD card Verify that the files including the hex file have been extracted into the TSTAT folder of the micro SD card A13254 S...

Page 53: ...ro SD card may be removed S This completes the software upgrade process Updating Software Using Wi Fi When software updates are available this reminder message will be displayed on the home screen A13...

Page 54: ...are update process All of your previously stored information and settings will be maintained NOTE Select DETAILS to view the release notes associated with the software to be downloaded Selecting NO wi...

Page 55: ...49 Model Serial Numbers This screen will allow you to access the model numbers and serial numbers for the installed equipment A14255...

Page 56: ...he Infinity System Control and click the downloads tab to down load the MyInfinity computer Desktop application for either PC or MAC Install the software on your computer then go to the Menu and selec...

Page 57: ...A170239C NOTE Options available on this screen will correspond to the equipment attached Options may appear that are different than those shown below S The default is for the system to Control the hea...

Page 58: ...Then use the on screen keyboard to type in the name you want for that particular zone Home Automation System Interface If Applicable The Infinity System Control can connect to a variety of home autom...

Page 59: ...omputer network or mobile device the Infinity System Control and or the MyInfinity web server with and the availability of the user s Internet service provider or mobile device carrier service Carrier...

Page 60: ...touching ENABLED S Touch SETUP A WI FI CONNECTION to begin the process S Next touch SCAN FOR AVAILABLE ACCESS POINTS A13235 S On the next screen look for the SSID of the router access point After bein...

Page 61: ...ty it will show as on the left but a secured network will prompt for the Wi Fi security key A150191 S If a Wi Fi security key is shown as on the right hand picture above then select the white bar and...

Page 62: ...8 S After the Control has connected to the network go to www MyInfinityTouch com to register the unit and begin remote access This requires the MAC address and serial number of the Infinity System Con...

Page 63: ...57 A170285C S When the connection to the MyInfinity web server has been established the status screen will show Connected for both Wi Fi and the server A13242C...

Page 64: ...CHANGE CURRENT LOCATION S Next select your country United States or Canada S To enter your postal code touch in the blank area then enter your postal code using the on screen keyboard Note that you ma...

Page 65: ...ontrol This sensor is used to control occupancy for the entire home including all zones in zoning systems By selecting the SENSORS icon in the menu a menu will be shown that offers options to setup th...

Page 66: ...60 A170286 Sensors Menu for Non Zoning System...

Page 67: ...used to enable or disable the occupancy sensing feature in the home or each zone for zoning systems NON ZONING SYSTEMS A170174 ZONING SYSTEMS A170175 NOTE Occupancy sensing indicator ONLY displays on...

Page 68: ...rice response or demand response events to your Wi Fi enabled Infinity System Control When a price response or demand response event is received your temperature set points will be automatically adjus...

Page 69: ...of that program Price Response Price response determines how the heating and cooling set points will be adjusted during a pricing event with two choices offsets or absolute temperature When offsets a...

Page 70: ...Demand Response Demand response determines how the heating and cooling set points will be adjusted during a demand response event with two choices offsets or absolute temperature When offsets are sel...

Page 71: ...rammed the Infinity System Control Thermostat will use the more favorable set point for the duration of the event A14266 Response Limits Response limits are minimum heating and maximum cooling tempera...

Page 72: ...66 Restore UE Factory Default Settings Restore UE Utility Event factory default settings will restore all utility event set points and price settings to their original factory default values A14268...

Page 73: ...d in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipme...

Page 74: ...xempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause...

Page 75: ...69 NOTES...

Page 76: ...Alliance Corporation Amazon Alexa is a trademark of Amazon Inc or its affiliates TP LINK is a trademark of TP Link Technologies Co Ltd The Bluetooth word mark and logos are owned by Bluetooth SIG Inc...