Step 2—Install Smart Sensor

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing sensor, turn off all power to unit. There may
be more than 1 power disconnect.

1. Turn OFF all power to unit.

2. If an existing thermostat or sensor is being replaced:

a. Remove existing device from wall.

b. Disconnect wires from existing device, 1 at a time. Be

careful not to allow wires to fall back into wall.

c. Discard or recycle old device.

d. If 4 wires exist in wall, they may be used. If not, plan and

route wiring to connect with either the Damper Control
Module, or User Interface. Multiple Smart Sensors may be
daisy chained together, but somewhere chain must connect
to either Damper Control Module or User Interface. (Smart
Sensor daisy chain wire limit is 100 ft.)
Recommended connection is:
A - Green = Data A
B - Yellow = Data B
C - White = 24vac (com)
D - Red = 24vac (hot)

NOTE:

It is not mandatory that the above color code be used, but

each ABCD connection in the system MUST be wired consis-
tently.

3. To mount Smart Sensor, remove rear mounting base. Route

wires through hole in mounting base and level base against
wall.

4. Mark wall through 2 mounting holes and drill two 3/16-in.

holes. Secure assembly to wall with 2 anchors and screws
provided, making sure all wires properly extend through
opening.

5. Adjust length and routing of thermostat wire to reach each

terminal entry on the connector. Strip 1/4-in. of insulation
from each wire and properly connect to A-B-C-D.

6. Push any excess wire into the wall. Seal hole in wall to prevent

any air leaks. Leaks can affect Smart Sensor operation.

7. Attach Infinity™ Smart Sensor to the mounting base by lining

up the plastic guides and gently snapping assembly together.

ELECTRICAL OPERATION HAZARD
Failure to follow this caution may result in equipment damage
or improper operation.
Improper wiring or installation may damage the Smart
Sensor. Check to make sure wiring is correct before proceed-
ing with installation or turning on unit.

Step 3—Setup and Checkout

NEW SMART SENSOR SETUP

Upon initial power up, the Smart Sensor will need to be properly
addressed. The ZONE icon will be displayed and default zone
number

2

will be shown in the temperature display. The word

SETUP will also appear in the lower left text area. Use the TEMP
(+/-) button to select the correct zone address number 1 through 8.
If only one Damper Control Module exists, the zone address
selection will only be 1 through 4. Once the zone number is

selected, press the FAN button to store the zone address and exit
the setup menu. The Smart Sensor is ready to operate.

CHANGING ZONE ADDRESS

To change an existing zone address; enter the setup menu by
pressing the FAN button for 10 seconds until the ZONE icon is
displayed. Use the TEMP (+/-) button to select the correct zone
address and then press the FAN button once to automatically save
and exit the setup menu. If no buttons are pressed for approxi-
mately 3 minutes, the screen will automatically save and exit back
to a normal display.

NOTE:

If the Zone Control (User Interface) is configured for

non-programmable operation, the Smart Sensor will ignore HOLD
and Override functions at the Smart Sensor.

BACKLIGHTING

The LCD backlighting will energize whenever a button is pressed.
The backlighting will de-energize after 10 seconds of no push
button or activity. To enable constant backlighting, press the FAN
button for 10 seconds to enter setup menu. Use the HOLD button
to toggle between

LIGHT OFF

and

LIGHT ON

which will

enable a fixed low intensity backlight. Press the FAN button to
save all settings and exit the setup menu.

FAN BUTTON

Pressing the FAN button momentarily will scroll through: AUTO,
LOW, MED, and HIGH speed continuous fan operation. Also, the
FAN button is used to enter into the setup mode by holding the
FAN button for 10 seconds.

HUMIDITY/OAT BUTTON

Pressing the HUMIDITY/OAT button will toggle between the
Outside Temperature and Indoor Relative Humidity reading (hu-
midity reading at User Interface). The LCD will revert back to the
outside temperature after 5 seconds.

COOL/HEAT BUTTON

Use the COOL/HEAT button to change between

COOL AT

and

HEAT AT

setpoints.

TEMPERATURE UP/DOWN BUTTON

Use the TEMP (+/-) button to change and select a zone tempera-
ture setpoint. Changing the setpoint will cause the Override timer
to be displayed (i.e. 2-hours). This can either be increased or
decreased by using the TIME (+/-) button. In addition, if the active
mode is heating; the

HEAT AT

icon will appear, or likewise

COOL AT

icon will appear, depending on the mode setting at

the Zone Control (User Interface).

TIME UP/DOWN BUTTON

When the TIME (+/-) button is pressed during a normal operation,
the

OVERRIDE

icon is displayed and the timer is shown

(default is 2-hours). The program will continue to hold the
currently displayed setpoint for that amount of time. While the
timer is shown, the TIME buttons can be used to raise or lower the
Override timer in 15-minute increments up to a maximum of 24
hours. If the time is decreased to zero, the Override text disappears
along with the timer and the program resumes regular operation.

HOLD/UNOCCUPIED BUTTON

Pressing the HOLD button momentarily will display the

HOLD

icon and the system will continue using the active (displayed)
temperature setpoints indefinitely. Pressing the HOLD button
again removes the

HOLD

icon and the system resumes normal

programming schedules.
Pressing the HOLD button for approximately 3 seconds activates
the

UNOCCUPIED

icon. This will be displayed in the lower left

area of the LCD and the unoccupied temperature settings will be

2

Summary of Contents for Infinity Smart Sensor

Page 1: ...e a Smart Sensor It provides a temperature display and buttons to adjust the desired temperature in that zone only It also displays outdoor temperature and indoor humidity The Smart Sensor can be home run wired directly to the Damper Control Module or daisy chained from the User Interface or another Smart Sensor via 4 wire ABCD communication bus Ordinary thermostat wire is recommended however soli...

Page 2: ...essing the FAN button for 10 seconds until the ZONE icon is displayed Use the TEMP button to select the correct zone address and then press the FAN button once to automatically save and exit the setup menu If no buttons are pressed for approxi mately 3 minutes the screen will automatically save and exit back to a normal display NOTE If the Zone Control User Interface is configured for non programm...

Page 3: ... the VACATION mode is activated from Zone Control User Interface the Smart Sensor will display the VACATION icon in the lower left area of the LCD If the TEMP button is pressed the Override timer will display 2 hours This can either be increased or decreased with the TIME button When the Override timer expires the Vacation setpoints return ERROR DISPLAY COM ERROR Communication Error will be displa...

Page 4: ...onnections and the other for equipment connections NOTE DAMPER CONTROL MODULE ZONES 1 4 A B C D RED GREEN YELLOW WHITE SMART SENSOR S TO USER INTERFACE AND OR DAISY CHAIN OPTION TO OTHER SMART SENSORS IF AVAILABLE TO EQUIPMENT OR ACCESSORY CONNECTIONS A B C D RED COMMUNICATION BUS GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C ...

Page 5: ...D UNOCCUPIED Pressing HOLD UNOCCUPIED button will display HOLD allowing setpoints to remain permanent and override any existing program schedules Pressing HOLD UNOCCUPIED button again will release HOLD and return to previous program schedules Pressing HOLD UNOCCUPIED button for approximately 3 seconds will display UNOCCUPIED status on lower left screen Pressing button again for approximately 3 sec...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...zonesms 1si Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 1 4 4 Tab 3a 5a 2a 5a PC 101 Catalog No 809 50013 Printed in U S A Form ZONESMS 1SI Pg 8 7 04 Replaces NEW ...