RECOMMENDED RELATIVE HUMIDITY 

BY OUTDOOR TEMPERATURE

 

* Indoor relative humidity level when outdoor air is heated to 72°F.

† As stipulated by the Air Conditioning Contractors of America.

 

MAXIMUM MOISTURE REQUIREMENTS

 

*

 

* Based on design conditions of outdoor 20°F dry bulb, 80% RH; indoor 70°F dry bulb, 40% RH, and

minimum moisture production from residential operations for an absolute humidity difference of 0.0049
lb/hr.

 

NOTE:

 

Tight house is defined as being well insulated, having vapor barriers, tight storm doors and
windows with weatherstripping, and having dampered fireplaces.
Average house is defined as being insulated, having vapor barriers, loose storm doors and
windows, and having dampered fireplaces.

 

OUTDOOR

TEMP

(°F)

OUTDOOR 

RELATIVE 
HUMIDITY

(%)

INDOOR RELATIVE 

HUMIDITY (%)

W/O HUMIDIFIER*

 MAXIMUM 

RECOMMENDED 

INDOOR 

RELATIVE 

HUMIDITY†

–10

 

30 to 70

1 to 2

20 (Lo)

 

0

 

30 to 70

2 to 4

25

 

10

 

30 to 70

3 to 6

30

 

20

 

30 to 70

4 to 10

35

 

30

 

30 to 70

6 to 15

40 (Med)

 

VOLUME OF 
RESIDENCE 

(CU FT)

TIGHT

HOUSE

AVERAGE

HOUSE

 Pounds

Per Hour

Gallons
Per Day

Pounds

Per Hour

Gallons
Per Day

  8,000

 

1.76

  5.09

  3.52

10.17

 

10,000

 

2.21

  6.35

  4.41

12.72

 

12,000

 

2.64

  7.63

  5.29

15.26

 

14,000

 

3.09

  8.91

  5.92

17.08

 

16,000

 

3.53

10.18

  7.06

20.35

 

18,000

 

3.97

11.45

  7.94

22.89

 

20,000

 

4.41

12.72

  8.82

25.44

 

22,000

 

4.85

13.99

  9.71

27.98

 

24,000

 

5.29

15.27

10.59

30.52

 

26,000

 

5.74

16.54

11.47

33.07

 

28,000

 

6.18

17.81

12.35

35.61

 

30,000

 

6.62

19.08

13.24

38.16

 

INDOOR RELATIVE HUMIDITY LIMIT

FOR NO WINDOW CONDENSATION

(Indoor Air at 74°F Dry Bulb

 

)

 

OUTDOOR

TEMPERATURE (°F)

 SINGLE

PANE WINDOWS (%)

 DOUBLE

PANE WINDOWS (%)

40

 

39

59

 

30

 

29

50

 

20

 

21

43

 

10

 

15

36

 

0

 

10

30

 

–10

 

7

26

 

–20

 

5

21

 

–30

 

3

17

Summary of Contents for HUMCCLBP2018-A Series

Page 1: ...fan The HUMCCLFP offers high evaporation rate up to 25 gallons of moisture per day For smaller tighter constructed or well insulated homes the HUMCCSFP can deliver up to 16 gallons of moisture per da...

Page 2: ...MCCWTR is rated up to 19 gallons of moisture per day and because of its no drain construction it is perfect for areas where hard water is not a problem This Model is a bypass humidifier and is reversi...

Page 3: ...eight lb 8 9 8 5 15 10 9 11 4 Water Usage Gal hr 3 2 Float Controlled ELECTRICAL CONTROL Low Voltage Terminals Volts 24 vac Amps Max 0 50 0 13 VA Max 12 3 Watts 10 3 High Voltage Cord Volts NA 115v 1P...

Page 4: ...DRAIN 12 12 5 10 18 WATER INLET OPTIONAL WATER VALVE MOUNTING SIDE DOOR 24VAC 115V PLUG CORD FRONT ACCESS COVER 8 13 16 DRAIN ACCESS PANEL TOP BOTTOM WATER INLET 24 VAC 115 VOLT PLUG CORD 16 5 8 5 8 1...

Page 5: ...OUTDOOR RELATIVE HUMIDITY INDOOR RELATIVE HUMIDITY W O HUMIDIFIER MAXIMUM RECOMMENDED INDOOR RELATIVE HUMIDITY 10 30 to 70 1 to 2 20 Lo 0 30 to 70 2 to 4 25 10 30 to 70 3 to 6 30 20 30 to 70 4 to 10 3...

Page 6: ...DIFFERENTIAL STATIC IN WC FAN UNIT CAPACITY VARIES ONLY W AIR TEMP AT 0 20 STATIC POINT NOTE DUCT STATIC HAS NO EFFECT ON 49FH HUMCCLFP HUMCCLBP HUMCCSBP HUMCCWTR HUMCCSFP PERCENTAGE INCREASE AGAINST...

Page 7: ...7 Typical humidifier installations UPFLOW HORIZONTAL A98353 A96491 A98354 A96493 DOWNFLOW UPFLOW...

Page 8: ...edge of the equipment discussed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available...

Reviews: