12
62--10601
S
TART-
S
TOP
O
PERATION
FAULT
STAND-BY
START/STOP
FUNCTION
CHANGE
UNIT
DATA
PRETRIP
CHECK
AUTO S/S
CONTINUOUS
MANUAL
DEFROST
ENTER
SETPOINT
BOX TEMPERATURE
FAULT
STANDBY
POWER ON
1
0
START/RUN
OFF
STANDBY
ENGINE
----22220000....0000 33334444....5555°°°° FFFF
1. Press the AUTO S/S-CONTINUOUS
toggle key until START-STOP is
displayed. Unit is now in Automatic
Start/Stop mode.
START/STOP
Automatic start/stop is provided to permit starting/restarting of the
diesel-driven
compressor
as
required.
This
gives
the
microprocessor automatic control of starting and stopping the
diesel engine. The main function of automatic start-stop is to turn
off the refrigeration system near the setpoint to provide a fuel
efficient temperature control system and then restart the engine
when needed. Start-Stop operation is normally used for frozen
loads. Refer to R
ECOMMENDED
T
RANSPORT
T
EMPERATURES
(See Page
32).