background image

4

5. Set the humidity set point for the holiday by pressing the

soft key under the humidify icon. Press the UP or DOWN

button until the desired humidity is shown.
NOTE: A humidify icon will only be shown for

33CS2PPRH thermostats.

6. Set the mode for the thermostat during the holiday by

pressing the MODE button. Press the MODE button until

the arrow is pointing to the desired mode.

7. Press the DONE button when complete.
8. Close the thermostat door.

Activating the Holiday Program — 

The user must

schedule a return date to activate the  holiday settings before

leaving. The thermostat will begin following the holiday

schedule after the  return date has been selected. On 12:00 AM

of the return date, the thermostat will automatically switch to

the programmed schedule.

To activate the holiday program, perform the following:

1. Press the SCHEDULE button until the arrow is next to

“holiday.”

2. The next day’s date will be displayed at the bottom of the

screen under the words “return on.” There will be a box

around the date. To set the date (D), press the UP button

and stop on the desired date.

3. If the month (M) needs to be changed, press the soft key

under the month on the screen. The selection box will

move to the month number. Press the UP button to set the

desired month.

4. Repeat this process to change the year (Y), if necessary.
5. Press the DONE button. This will instruct the thermostat

to begin the Holiday schedule immediately.

6. Close the thermostat door.

Turning the Heating and Cooling System Off
 — 

To use the thermostat to turn the heating and cooling sys-

tem off, perform the following:

1. Open the thermostat door.
2. Press the MODE button until the display shows “off” in

the upper right corner.

3. Close the thermostat door.

Changing the Humidity Level — 

Some thermostats

offer three humidity options: normal, auto, and off. This func-

tion is only available on 33CS2PPRH thermostats.

The thermostat is set at the factory for “normal humidify,”

which is a fixed humidity setting based on how much humidity

the user wants in the space. This humidity level remains

constant, regardless of the outdoor temperature. The user can

manually adjust the humidity level according to their own

preferences.

The second option, “auto humidify,” uses an outdoor tem-

perature sensor (if installed) to automatically adjust the indoor

humidity level according to the outside temperature.

The third option is to turn off the humidify/dehumidify

feature.

To change the fixed (constant) humidity setting for normal

humidify, perform the following procedure:

1. Open the thermostat door.
2. The “humidify” icon will be displayed  at the bottom of

the screen when the operating mode is heat. The  “dehu-

midify” icon will be displayed when the operating mode

is cool.

3. Press the soft key under the humidify or dehumidify

icons. The screen will display the current setting.

4. Press the UP or DOWN button to change the humidity

setting. It is factory set at 26% for humidify and 60% for

dehumidify. If there is too much condensation in the

space, set the value to a lower number. If the air is too dry,

set the value to a higher number. Humidity can be set to

between 10% and 46%. The dehumidify range is from

46% to 98%.

5. Close the thermostat door.

To change the humidity setting for auto humidify, perform

the following procedure:

1. Open the thermostat door.
2. The “humidify” icon will be displayed  at the bottom of

the screen. Press the soft key under the humidify icon.

The screen will display the current setting.

3. Press the MODE button. An auto icon will appear at the

top of the screen. The current humidity reading and the

auto humidify set point will also be shown. The default

auto humidify set point is 5.

4. Press the UP or DOWN button to change the auto humid-

ify setting number (1 through 9). If there is too much

condensation on the windows, select a number lower than

5. If there seems to be a lot of static electricity, which of-

ten means the air is too dry, select a number higher than 5.

5. Close the thermostat door.

To turn off the humidify or dehumidify feature open the

thermostat door. Press the soft key under the humidify or dehu-

midify icons. Then press the MODE button until the screen dis-

plays OF. Close the thermostat door.

Using Emergency Heat — 

Emergency heat should be

selected when it is desirable to heat the space with the auxiliary

heat only.

To set the thermostat to use emergency heat, perform the

following procedure:

1. Open the thermostat door.
2. Press the MODE button repeatedly until the arrow under

the button moves to the “Em heat” indicator on the

screen.

3. Close the thermostat door.

Advanced Programming  — 

The user can customize

several features of the thermostat. See Table 3.

Table 3 — Configuration Options

RESET REMINDERS  — The thermostat will display when

it is time to change the UV (ultraviolet) light, change the filter,

or perform scheduled maintenance to the equipment. When the

reminder icons are displayed on screen, pressing and holding

the DONE button for about 3 seconds will clear all reminders.

This might not be desirable when multiple reminders are

shown.

The reminders can also be reset individually. To reset indi-

vidual reminders, perform the following:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01”

OPTION

NUMBER

CONFIGURATION

01

Reset Reminders

02

Fahrenheit/Celsius Selection

03

Backlighting

04

Unused

05

Programmable/Non-Programmable Selection

06

Number of Programming Periods

07

Unused

08

Daylight Savings Time

Downloaded from 

ManualsNet.com

 search engine

Summary of Contents for EDGE Pro 33CS2PP2S-03

Page 1: ...ed settings in memory During power loss its in ternal memory saves settings for unlimited time and the clock continues to run for at least 24 hours An extension of Carrier s proven line of thermostats the Edge Pro thermostat provides separate set points for heating and cooling in addition to hu midification and dehumidification OPERATION Thermostat Display The thermostat display is locat ed in the...

Page 2: ... temporary hold period perform the following Open the front thermostat door An arrow will be displayed next to the words off heat or cool in the upper right corner on the screen de pending on the mode the system is in If it is the first time the thermostat is being used the heat indicator will be displayed The preprogrammed heating or cooling temperatures are dis played in a box at the bottom of t...

Page 3: ...ays of the week will not fol low the same schedule perform the following 1 Fill in Table 2 with the desired times and set points for each day Use this table as a guide during programming and for future reference 2 Open the thermostat door 3 Press the SET button until the screen displays daily schedule in the center of the screen The list of the days of the week are displayed on the left 4 There wi...

Page 4: ...ll be displayed when the operating mode is cool 3 Press the soft key under the humidify or dehumidify icons The screen will display the current setting 4 Press the UP or DOWN button to change the humidity setting It is factory set at 26 for humidify and 60 for dehumidify If there is too much condensation in the space set the value to a lower number If the air is too dry set the value to a higher n...

Page 5: ...wn P stands for programmable and nP stands for non programmable 5 Press the DONE button 6 Close the thermostat door NUMBER OF PROGRAMMING PERIODS The ther mostat is preset with four programmable time periods This can be changed to two To change the number of time periods per form the following procedure 1 Open the thermostat door 2 Press and hold the buttons underneath the heat and cool set points...

Page 6: ...IPTION E1 The system is not communicating properly Call your local Carrier representative for service E3 The temperature sensor has failed Call your local Carrier representative for service E4 There is an internal memory failure Call your local Carrier representative for service E5 The humidity sensor is not working Call your local Carrier representative for service Downloaded from ManualsNet com ...

Page 7: ...Downloaded from ManualsNet com search engine ...

Page 8: ... change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53330031 01 Printed in U S A Form 33CS 26SO Pg 8 6 13 Replaces 33CS 21SO Carrier Corporation 2013 Downloaded from ManualsNet com search engine ...

Reviews: