2

 

be installed in upflow, downflow, or
horizontal positions covering up to 
24 different applications.
The versatile 4-way multipoise design 
in conjunction with variable speed 
makes the Infinity 96 is ideal for use 
with split-system cooling, including
2-speed units. A Carrier electronic 
air cleaner, humidifier, 
Thermidistat™, comfort ventilator, 
and Comfort Zone

 

TM

 

 II will provide 

year-round comfort and efficiency.
Designed for durability, comfort,
and reliability, the Infinity 96 is the 
ultimate in versatile, efficient comfort.

 

Carrier Infinity® System

 

 — When 

the Infinity 96 variable-speed gas 
furnace is matched with the Infinity 
Control and an air conditioner or heat 
pump, you will experience the ulitmate 
in ComfortHeat and Ideal Humidity 
through unparalleled control of 
temperature, humidity, indoor air 
quality, and zoning. The Carrier Infinity 
System also provides unprecedented 
ease of use through on-screen, text-
based service reminders and equipment 
malfunction alerts.
For even greater comfort and 
convenience, match the Infinity 96 
furnance with an Infinity air 
conditioner or heat pump. This will 
create a fully communicating system, 
requiring only 4 thermostat wires 
between system components, and 
troubleshooting can even be done from 
the outdoor unit without entering the 
home.
Optional remote access through 
telephone or Internet is also available 
when combined with a remote 
connectivity kit.

 

Infinity 96 FEATURES/
BENEFITS

 

ComfortHeat

 

 — On the coldest days 

of the year, the Infinity 96 Furnace has 
the capacity to heat your home. On 
moderate days when less heat is 
required, this furnace will regulate 
itself to a lower capacity —
providing a comfortable home and 
minimizing operating costs.
The patented algoritum adjusts the 
low-heat operating time to match the 
indoor conditions.

 

IdealHumidty

 

 — The IdealHumidity 

system actively controls both 
temperature and humidity in your home 
to provide the best comfort all year 
long. Other systems depend on heating 
or cooling to manage the moisture in the 
air. But, IdealHumidity gives you the 
right amount of humidity day and night, 
even in mild weather. 

 

No other 

manufacturer can do this! 

 

IdealHumidity saves energy, too. By 
keeping humidity under control, you 
can set your thermostat to stay 
comfortable and save energy—

 

up to 

20% off your cooling costs!

 

 

 

Media Filter Cabinet

 

 — Enhanced 

indoor air quality in your home is made 
easier with our media filter cabinet—a 
standard accessory on all deluxe 
furnaces. When installed as a part of 
your system, this cabinet allows for 
easy and convenient addition of a 
Carrier high-efficiency air filter.

 

Insulated Blower Compartment

 

 — 

The acoustical insulation reduces air 
and motor noise for quiet operation.

 

Certifications

 

 — The Infinity 96, 

Model 58MVP units are A.G.A. and 
C.G.A. design certified for use with 
natural and propane gases. The furnace 
is factory-shipped for use with natural 
gas. An C.S.A. (A.G.A. and C.G.A.) 
listed gas conversion kit is required to 
convert furnace for use with propane 
gas. The efficiency is GAMA 
efficiency rating certified. The Infinity 
96 meets California Air Quality 
Management District emission 
requirements. 

 

Quality Registration

 

 — The Infinity 

96 is engineered and manufactured 
under an ISO 9001 registered quality 
system.

 

Venting

 

 — The combustion-air and 

vent pipes can terminate through a side 
wall or through the roof when used 
with a factory-authorized vent 
termination kit.

 

Blower Access Panel Switch

 

 —

Automatically shuts off 115-v power 
to furnace whenever blower access 
panel is opened.

 

Reliable Heat Exchanger Design

 

 — 

The primary heat exchanger is made of 
aluminized steel for corrosion resistance.
The patented Serpentuff

 

TM

 

 condensing 

heat exchanger cells are laminated 
with polypropylene for greater 
resistance to corrosion and epoxy 
coated externally to prevent oxidation. 
This break-through in heating 
technology helps extend the life of the 
furnace for years of dependable 
performance. The heat exchanger is 
positioned in the furnace to extract 
additional heat.

 

Warranty

 

 — The Infinity 96 heat

exchangers come with a Limited
Warranty for lifetime of original
owner in single family residence; 
20 years in other residential and 
commercial applications. Five-year 
limited warranty on entire unit. 
Contact your dealer for details.

 

Electronic Variable-Speed Motors 

 

 

—ECM

 

 

 

Motors (Electronically 

Commutated Motor) provide variable-
speed operation to optimize comfort 
levels in the home year round. They 
are also more economical to operate 
than standard motors.

 

Comfort Heat Control Center

 

 — 

The microprocessor control center
features state-of-the-art combustion, 
temperature, and airflow control to 
maximize comfort while operating at 
peak efficiency.
Combustion control is obtained by 
taking the appropriate inducer motor 
RPM readings when the low- and high-
fire pressure switches are made. Using 
this information, the microprocessor 
maintains a consistent air-to-fuel ratio 
independent of vent sizing and 
conditions.
The first cycle after power reset
provides 16 minutes of low heat 
before switching to high heat unless 
the room thermostat has been satisfied.
Subsequent thermostat cycles provide 
anywhere from 0 to 16 minutes of low 
heat depending on the length of the 
previous thermostat cycle.
Airflow control is accomplished by 
using a technique involving the 
microprocessor and blower motor. The 
static load on the air delivery system is 
measured each heating cycle. The 
microprocessor then uses this 
information to deliver correct airflow 
independent of variations in system 
restrictions. (For example, dirty filter or 
zone damper changes during a cycle.)
A special dehumidification function 
allows direct input from a thermidistat 
or humidistat. This input adjusts 
system airflow for greater humidity 
removal and increased cooling comfort 
during summer months.

 

Insulation

 

 — Foil-faced insulation in 

heat exchanger section of the casing 
minimizes heat loss.

 

Direct Vent Sealed Combustion
System

 

 — Infinity 96 uses 100 percent 

outdoor air, which results in especially 
quiet operation. Direct venting 
minimizes the possibility of using 
contaminated air and also reduces air 
infiltration draftiness in the home.

 

Monoport Burners

 

 — The burners 

are finely tuned for smooth, quiet 
combustion and economical operation.

 

Bottom Closure

 

 — Factory-installed 

for side return; easily removable for 
bottom return.

 

ComfortFan™

 

 — Improves comfort 

all year long by allowing you to select 
the continuous fan speed right at the 
thermostat.

 

SmartEvap™

 

 — Allows your system 

to reduce summertime humidity levels 
by nearly 10% over standard systems.

Summary of Contents for Deluxe 58MVP

Page 1: ...ion while meeting the exact heating needs This unit is designed to keep the indoor temperature within 1 degree of the thermostat setpoint Because it op erates in low heat most of the time the Infinity 96 uses up to 80 less power than single capacity furnaces In addition to providing ultimate com fort the Infinity 96 has a sealed com bustion system This system brings combustion air from outdoors to...

Page 2: ... engineered and manufactured under an ISO 9001 registered quality system Venting The combustion air and vent pipes can terminate through a side wall or through the roof when used with a factory authorized vent termination kit Blower Access Panel Switch Automatically shuts off 115 v power to furnace whenever blower access panel is opened Reliable Heat Exchanger Design The primary heat exchanger is ...

Page 3: ...es ensure adequate flow of flue products through furnace and out vent system Inducer motor Pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety Condensate drain connection Collects moisture condensed during combustion process Heavy duty blower Circulates air across the heat exchangers to transfer heat into the home Air filter and retainer May be used for ...

Page 4: ...EDIA FILTER WITH END CAPS 24 IN 6 pack EXPXXLMC0024 X X REPLACEMENT EZ FLEX FILTER 16 IN 10 pack EXPXXFIL0016 X REPLACEMENT EZ FLEX FILTER 20 IN 10 pack EXPXXFIL0020 X X X REPLACEMENT EZ FLEX FILTER 24 IN 10 pack EXPXXFIL0024 X X UNFRAMED FILTER ONE INCH 16 X 25 KGAWF1306UFR 6 pack S X S S S UNFRAMED FILTER ONE INCH 20 X 25 KGAWF1406UFR 6 pack X X X UNFRAMED FILTER ONE INCH 24 X 25 KGAWF1506UFR 6 ...

Page 5: ... configured for multiple use staging it must be configured for each specific application NON PROGRAMMABLE THERMOSTAT SELECTION TSTATCCNAC01 B For use with 1 spd Air Conditioner deg F c Auto Changeover TSTATCCNHP01 B For use with 1 spd Air Conditioner deg F C Auto Changeover TSTATCCN2S01 B For use with 2 spd Air Conditioner deg F C Auto Changeover TSTATCCPRH01 B For multi use stage configurations d...

Page 6: ...P fur naces when installed in downflow applications CONTROL CENTER INDUCER ASSEMBLY FLASH UPGRADE CONNECTOR FACTORY ONLY ACRDJ AIR CONDITIONING RELAY DISABLE JUMPER HUMIDIFIER TERMINAL 24 VAC 0 5 AMP MAX CONTINUOUS FAN CF AIRFLOW SETUP SWITCHES COMMUNICATION CONNECTOR AIR CONDITIONING A C AIRFLOW SETUP SWITCHES MODEL PLUG CONNECTOR SW1 SETUP SWITCHES AND BLOWER OFF DELAY STATUS AND COMM LED LIGHTS...

Page 7: ...idual zones of the home This is accomplished through a series of electronic dampers and remote room sensors The 4 zone system is shown A94336 ENERGY HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level Especially useful for today s tighter constructed houses Energy rec...

Page 8: ...3 7 93 7 93 7 93 7 93 7 INPUT BTUH Low 26 000 39 000 52 000 52 000 65 000 78 000 High 40 000 60 000 80 000 80 000 100 000 120 000 SHIPPING WEIGHT Lb 205 170 182 204 203 234 CERTIFIED TEMP RISE RANGE F Low 25 55 50 80 50 80 50 80 50 80 50 80 High 30 60 35 65 35 65 35 65 45 75 45 75 CERTIFIED EXT STATIC PRESSURE ESP Heating 0 10 0 12 0 15 0 15 0 20 0 20 In wc Cooling 0 50 0 50 0 50 0 50 0 50 0 50 AI...

Page 9: ... Cooling 1400 0 1 0 1370 1385 1385 1395 1395 1395 1395 1400 1395 1390 5 Ton A C Cooling 1750 0 1 0 1750 1750 1750 1750 1750 1750 1745 1740 1735 1725 Maximum 2000 0 1 0 2000 2000 2000 2000 1990 1975 1950 1925 1900 1865 100 20 Low Heat 920 0 1 0 920 915 915 920 920 920 915 900 895 890 High Heat 1525 0 1 0 1525 1525 1525 1525 1520 1515 1515 1515 1515 1515 2 Ton A C Cooling 700 0 0 50 700 700 700 690 ...

Page 10: ...0 0 1 0 298 340 384 417 458 493 534 574 607 647 5 Ton A C Cooling 1750 0 1 0 587 631 664 724 772 815 861 907 943 988 Maximum 2000 0 1 0 839 911 973 1029 1066 1104 1134 1149 1170 1182 100 20 Low Heat 920 0 1 0 113 136 159 186 221 243 263 285 316 340 High Heat 1525 0 1 0 378 419 448 486 518 561 606 650 696 730 2 Ton A C Cooling 700 0 0 50 74 89 109 126 146 2 1 2 Ton A C Cooling 875 0 0 50 99 124 147...

Page 11: ...OX DRAIN CONNECTION 1 2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4 26 4 FURNACE SIDE FURNACE SIDE 1 2 1 1 4 26 4 3 4 5 3 4 5 4 SIDE VIEW FRONT VIEW END VIEW FRONT VIEW 3 4 DOWNFLOW AND ALTERNATE E...

Page 12: ...TES 1 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements above...

Page 13: ...hout CD5 or CK5 Coil Assembly or KCAKC Coil Box 18 5 8 19 20 1 4 20 3 8 2 24 1 2 Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box 22 1 8 19 23 3 4 20 3 8 1 A97427 Assembled A88207 Disassembled LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION A00309 A Media Filter Cabinet A B 16 17 16 20 21 20 24 25 24 23 5 8 23...

Page 14: ... wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT BLK W W1 W2 Y Y2 G NOTES 1 2 3 Electrical data Permissible limits of the voltage range at which the unit will operate satisfactorily Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop Time delay type is recommended Typical wiring schematic UNIT SIZE 040 14 06...

Page 15: ...A NA 3 63 62 62 61 61 61 3001 to 4000 040 14 2 Pipe or 2 In Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 060 14 2 Pipe or 2 In Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 080 14 080 20 2 Pipe or 2 In Concentric 1 1 2 25 20 15 10 5 NA 2 70 70 70 70 70 70 100 20 2 Pipe or 2 In Concentric 2 38 33 28 23 18 13 2 1 2 70 70 70 70 70 70 120 20 2 Pipe or 3 In Concentric 3 29 24 10 NA N...

Page 16: ...8 67 66 64 080 14 080 20 2 Pipe or 2 In Concentric 1 1 2 20 15 10 5 NA NA 2 70 70 68 67 62 57 100 20 2 Pipe or 2 In Concentric 2 31 26 21 16 11 6 2 1 2 70 70 68 67 66 64 120 20 2 Pipe or 3 In Concentric 3 49 48 47 45 44 43 7001 to 8000 040 14 2 Pipe or 2 In Concentric 1 1 2 32 27 22 17 12 7 2 66 65 63 62 60 59 060 14 2 Pipe or 2 In Concentric 1 1 2 32 27 22 17 12 7 2 66 65 63 62 60 59 080 14 080 2...

Page 17: ...owable Pipe Length table Insulation thickness based on R value of 3 5 per in UNIT SIZE WINTER DESIGN TEMP F MAX PIPE DIA IN INSULATION THICKNESS IN 0 3 8 1 2 3 4 1 040 14 20 2 21 37 42 50 57 0 2 10 22 25 30 35 20 2 5 14 17 21 25 060 14 20 2 30 55 61 70 70 0 2 16 33 38 46 53 20 2 9 23 26 33 38 080 14 080 20 20 2 37 65 70 70 70 0 2 20 39 45 55 63 20 2 11 27 31 39 45 100 20 20 2 1 2 41 70 70 70 70 0 ...

Page 18: ...earance To Combustible Construction as described below This furnace requires a special venting system Refer to the installation instructions for parts list and method of installation This furnace is for use with schedule 40 PVC PVC DWV CPVC or ABS DWV pipe and must not be vented in common with other gas fired appliances Construction through which vent air intake pipes may be installed is maximum24...

Page 19: ...2307 Closet Downflow Application A02308 COMBUSTION AIR PIPE A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR OUTDOOR UNIT AIRFLOW FRONT OF FURNACE ...

Page 20: ...038 Printed in U S A PC 101 Form 58MVP 11PD Tab 6a 8a Replaces 58MVP 10PD COMBUSTION AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE Attic Horizontal Application A02309 Crawlspace Horizontal Application A02310 COMBUSTION AIR PIPE VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING ...

Reviews: