background image

OPERATING TEMPERATURE

Mode

Cooling operation

Heating operation

Drying operation

Temperature

1. If  air  conditioner  is  used outside of the above conditions, certain safety  protection 
    features may come into operation and cause the unit to function  abnormally.
2. Room  relative  humidity less  than  80%. If  the air conditioner operates in excess of this
    figure, the surface of the air conditioner may attract condensation. Please sets the vertical
    air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.

Room temperature

Outdoor temperature

CAUTION:

MANUAL  OPERATION

Manul operation can be used temporarily in case you can not find the remote controller or
its batteries are exhausted.

To achieve optimal performance, please note the following:

Adjust the air flow direction correctly so that  it is not directed on people.

Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to

excessive temperature levels.

Close doors and windows on COOL or HEAT modes, or performance may be reduced.

Use TIMER ON button on the remote controller to select a time you want to start your

 air conditioner.

OPTIMAL  OPERATION

5

Manual control 

button

Panel

AUTO/COOL

Open and lift the front panel up to an angle until
it remains fixed  with a clicking sound.
One press of the manual control button will lead
to the forced AUTO operation.
Close the panel firmly to its original position.

Once  you  push the  manual button,  the operation
mode is shifted in an order as:  AUTO,  COOL, OFF.
Push the button twice, the unit will operate  in 
 forced COOL mode. This is used for testing 
 purposes only .
 Third press will stop the operation and turn off 
 the air conditioner operation.
To restore the remote controller operation, use the
 remote controller directly.

CAUTION:

1

3

2

17 C   32 C

18 C    43 C

0 C       3 0 C

-7 C    24 C

17 C   32 C

11 C       4 3 C

~

~

~

~

( -5 C    43 C:For the models with 

low temperature cooling system)

~

~

~

Summary of Contents for CS311-U

Page 1: ...Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner OWNER S MANUAL Split type Room Air Conditioner...

Page 2: ...ems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance o...

Page 3: ...earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause e...

Page 4: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the u...

Page 5: ...iods of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purpos...

Page 6: ...chased depend on model The actual shape shall prevail 4 3 5 2 6 1 10 9 12 13 11 7 8 8 Indoor unit Outdoor unit 1 Front panel 2 Air inlet 3 Air filter 4 Air outlet 5 Horizontal air flow grille 6 Vertic...

Page 7: ...it is not directed on people Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels Close doors and windows on COOL or HEAT modes or perform...

Page 8: ...ed direction Adjust the vertical air flow direction to the desired direction In subsequent operations the vertical air flow is automatically set in the direction to which you adjusted the louver by pr...

Page 9: ...normal operation CAUTION 7 AUTOMATIC OPERATION When you set the air conditioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on...

Page 10: ...er A cloth dampened with cold water may be used on the indoor unit if it is very dirty The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth Do not use...

Page 11: ...unit for a long time perform the following 1 Operate the fan for about half a day to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote con...

Page 12: ...relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air condition...

Page 13: ...emperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the...

Page 14: ...at plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section Clea...

Page 15: ...CS311 U...

Reviews: