Summary of Contents for Cor TP-WEM01-A

Page 1: ...TP WEM01 A Carrierr Côr Thermostat AC HP Wi Fir Thermostat Performance Series Installation Guide ...

Page 2: ...e here to help d Visit www carrier com corsupport for how to videos answers to frequently asked questions and advanced installation instructions d Technical support is also available by phone or email weekdays from 8 a m 5 p m EST d 1 800 CARRIER or 1 800 227 7437 d contact carrier carrier utc com d The Côr thermostat is also supported by the world s greatest network of professional contractors Fi...

Page 3: ... d Dual Fuel Systems Gas Furnace with a Heat Pump d Geothermal Systems d Accessories Whole Home Humidifier Dehumidifier or Ventilator d 802 11 b g n Home Wireless Router Before beginning installation check the compatibility of your home comfort system at www carrier com wirecheck Professional installation is recommended for d Systems Without a Common C Wire see page 5 d Variable Speed Systems d Fi...

Page 4: ...E BOX A The Côr Thermostat and backplate B Mounting screws and drywall plugs C Installation guide quick start guide and wire labels D Large Backplate optional Wire Labels Installation Guide Quick Start Guide A B C D A150042 ...

Page 5: ...ewdriver D Drill with a 3 16 drill bit E Password for your home s wireless network F Internet connected device such as a smartphone tablet or computer A F C D Password E B A150044 Tip Review all the instructions before you start to help ensure that there are no surprises during installation ...

Page 6: ...rrier com corsupport for Advanced Installation and Configuration Instructions B If you have wires connected to Rh Rc and C You ll use two breakers or switches to disconnect power in Step 2 B 110 120V H C H C A A150045 Warning If your old thermostat is labeled 110V or 120V or is connected by thick wires and wire nuts it is a high voltage system and is not compatible ...

Page 7: ...door furnace or fan coil Most systems have one switch but systems with Rh Rc and C wires noted in Step 1 will have two switches Make sure your system is without power by using your old thermostat to adjust the temperature Your system should not turn on or A150046 Warning Electrical operation hazard Failure to follow this warning could result in injury death or equipment damage ...

Page 8: ...Most thermostats wires are connected using screws simply loosen each screw with a screwdriver Remove your old thermostat base by unscrewing it from the wall Be careful not to let any wire labels fall off or wires fall back into the wall Discard any jumper wires or brackets between Rh Rc or R A150047 Tip Take a photo of your old thermostat wiring with your smartphone for reference later ...

Page 9: ...e back plate Mark the mounting holes on the wall with a pencil Drill mounting holes on the pencil marks with a 3 16 drill bit Insert the plastic drywall anchors into the wall Use the screws provided to secure the back plate to the wall A150048 Tip Check the built in bubble level to ensure your thermostat is straight ...

Page 10: ... use the large backplate instead Remove the terminal blocks from the small backplate by squeezing the tab on the front left side while gently pushing the back toward you Insert the terminal blocks into the large backplate using the tabs on the right as a guide It will snap into place when correctly inserted then A150049 ...

Page 11: ...talled correctly the release lever of the terminal block will lower to indicate a complete connection Gently tug on the wire to ensure it s fully connected When all the wires are connected gently push any excess wire back into the wall Rc G Y Y1 W1 AUX1 O B A150050 Tip If you need additional help with the wiring refer to the wiring diagrams at www carrier com corsupport ...

Page 12: ...hear it snap into place A150051 Now you can turn the power back on to your heating and cooling system Return to your circuit breaker or on off switch and restore the power to your system The Côr thermostat will automatically power on In about one minute its guided software setup will be ready to help you complete your installation ...

Page 13: ...rences 3 Connecting to your home s wireless network 4 Registering your thermostat online The information icon at bottom of the screen will provide helpful explanations and tips for each step in the process i A150052 Tip To save time we recommend having your home wireless network password and an Internet connected device close at hand before you begin ...

Page 14: ...t two d Otherwise select one b The Côr thermostat automatically detects the wires you ve connected and will ask a few questions to configure your system based on these connections c If you have a connected accessory such as a whole home humidifier dehumidifier or ventilation device you ll also configure it here Tip Use the photo you took of your old thermostat s wiring for confirmation ...

Page 15: ... customize your Côr thermostat a Name your thermostat by selecting a name from the list or by entering your own custom name b Tell the Côr thermostat whether you prefer the temperature to display in Fahrenheit or Celsius c Then adjust your home comfort temperature for the heating and cooling seasons ...

Page 16: ...at provides you the most features and energy savings when it s connected to your home s wireless network and your personal web portal a The Côr thermostat automatically detects nearby wireless networks b Select your network from the list and enter your network password ...

Page 17: ...device download the Carrier Côr thermostat app from the app store b Open the app and touch register on the login screen c Enter the four digit code generated from your thermostat and follow the onscreen prompts to complete your registration d Return to your thermostat and accept your registration A150053 Tip You can also register using your tablet or computer at www carrier com myhome ...

Page 18: ...ndoor equipment or the electri cal panel where you originally turned off the equipment 3 If your device still doesn t power on check the AC voltage between Rc and C or Rh and C using a multi meter to ensure it is 24V AC 4 If your device still does not power on please contact d Technical support at 1 800 CARRIER or contact contact carrier carrier utc com d Find an Expert Carrier Contractor at carri...

Page 19: ...r installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures d Reorient or relocate the receiving antenna d Increase the separation between the equipment and receiver d Connect the equipment into an outle...

Page 20: ...ration of the device Le présent appareil est conforme aux CNR d Industrie Canada applicable aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonction nement Thi...

Page 21: ...NOTES ...

Page 22: ......

Page 23: ......

Page 24: ...ght 2016 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 07 16 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Replaces TP WEM 04SI Catalog No TP WEM 05SI ...