FIRE AND EXPLOSION HAZARD

Failure to follow this hazard warning could result in

personal injury, death and/or property damage.
What to do if you smell gas:

1. Do not try to light any appliance.

2. Do not touch any electrical switch; do not use any phone

in your building.

3. Leave the building immediately.

4. Immediately call your gas supplier from a nearby phone.

Follow the gas supplier’s instructions.

5. If you cannot reach your gas supplier, call the fire

department.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury and/or death.
Before performing recommended maintenance, be sure the

main power switch to unit is turned off and lock--out tag is

installed.

!

WARNING

FIRE,

EXPLOSION,

ELECTRICAL

SHOCK

HAZARD

Failure to follow this hazard warning could result in

personal injury, death and/or property damage.
1. Do not turn off the electrical power to unit without first

turning off the gas supply.

2. Before attempting to start the gas heating section,

familiarize yourself with all the procedures that must be

followed.

!

WARNING

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
Do not attempt to light by hand.

!

WARNING

CUT HAZARD

Failure to follow this caution may result in personal injury.
When removing access panels or performing maintenance

functions inside your unit, be aware of sharp sheet metal

parts and screws. Although special care is taken to reduce

sharp edges to a minimum, be extremely careful when

handling parts or reaching into the unit.

!

CAUTION

UNIT INTRODUCTION

The 48EZ--A and 48VT--A units are small packaged gas
heat/electric heat pump systems that can utilize both the efficiency

of heat pump heating and the comfort of gas heating. The system
will optimize for ideal heating, depending on several factors. This

unit uses Puron

®

, the ozone friendly refrigerant, for cooling and

heat pump heating.

Starting or Shutting Off Unit

NOTE

: Your combination heating/cooling unit is equipped with

an automatic direct spark ignition and power combustion blower.

To start unit gas heat:

Refer to Fig. 3 for location of unit front access panel. Refer to Fig.

4 for location of gas valve. Refer to Fig. 5 while proceeding with
the following steps.

1. Set the temperature selector on room thermostat to the low-

est temperature setting and set system switch to Emergency

Heat.

2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16--in. nut driver.

(See Fig. 3.)

Compressor

Access

Panel

Filter Access Panel

For Accessory Filter Rack

Blower

Access

Panel

Control

Access

Panel

A09213

Fig. 3 -- Unit Access Panels

5. Move the selector switch on the internal gas valve to the

OFF position and wait 5 minutes.

6. Move the selector switch on the internal gas valve to the ON

position.

7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.

10. Set the temperature selector on room thermostat slightly

above room temperature to start unit. The induced--draft

combustion air fan will start. Main gas valve will open and
main burners should ignite within 5 seconds. If the burner

does not light within 5 seconds, the ignition module will go
into a Retry Mode after a period of approximately 22
seconds (following the 5--second ignition period). If the

burners do not light within 15 minutes of the initial call for
heat, there is a lockout.

Summary of Contents for COMFORT 48EZ-A

Page 1: ...al Fuel System With Puron R 410A Refrigerant Single and Three Phase 2 5 Nominal Tons Sizes 24 60 Owner s Information Manual A09034 48EZ A Without Economizer A10077 48EZ A With Economizer Fig 1 Unit 48EZ A A09033 48VT A Without Economizer A10078 48VT A 48VT A with Economizer Fig 2 Unit 48VT A ...

Page 2: ...ent editions of the National Fuel Gas Code NFGC NFPA 54 ANSI Z223 1 and the National Electrical Code NEC NFPA 70 In Canada refer to the current editions of the National Standards of Canada CAN CSA B149 1 and 2 Natural Gas and Propane Installation codes and Canadian Electrical Code CSA C22 1 Recognize safety information This is the safety alert symbol When you see this symbol on the unit and in ins...

Page 3: ...ed gas heat electric heat pump systems that can utilize both the efficiency of heat pump heating and the comfort of gas heating The system will optimize for ideal heating depending on several factors This unit uses Puron the ozone friendly refrigerant for cooling and heat pump heating Starting or Shutting Off Unit NOTE Your combination heating cooling unit is equipped with an automatic direct spar...

Page 4: ...oceeding with the following steps 1 Set the temperature selector on room thermostat to highest temperature setting and set system SWITCH to OFF 2 Close the external manual shutoff valve if not already closed 3 Turn off the electrical power supply to the unit NOTE Heat Pump heating mode procedure is similar to electric cooling mode except thermostat mode is HEAT and thermostat must operate on first...

Page 5: ...5 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 5 To Start Unit Gas Heat ...

Page 6: ...5 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 6 To Shut Off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 Fig 7 To Start Unit Electric Cooling ...

Page 7: ... the top of the unit is 48 in 1219 mm Clearance of at least 36 in 914 mm is required on sides except the power entry side 42 in 1067 mm clearance and the duct side 12 in 305 mm minimum clearance Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to maintain yourself please carefully consider the following FIRE EXPLOSION ELECTRICAL SHOCK AND CUT HAZARD F...

Page 8: ...5 mm 36 060 090 1 each 24 x 14 x 1 610 x 406 x 25 24 x 16 x 1 610 x 406 x 25 42 060 090 1 each 24 x 14 x 1 610 x 356 x 25 24 x 16 x 1 610 x 406 x 25 48 090 115 130 1 each 24 x 16 x 1 610 x 406 x 25 24 x 18 x 1 610 x 457 x 25 60 090 115 130 1 each 24 x 16 x 1 610 x 406 x 25 24 x 18 x 1 610 x 457 x 25 Units with bent indoor coil Large Chassis See Fig 10 1 Remove filter access door using a 5 16 in nu...

Page 9: ...one by a trained service person FIRE EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property damage If your unit makes an especially loud noise when the main burners are ignited shut down the heating section and call your dealer WARNING BURN HAZARD Failure to follow this caution may result in personal injury Components in heating section may be hot aft...

Page 10: ... COOL or HEAT and not OFF If your unit still fails to operate call your servicing dealer for troubleshooting and repairs Specify the model and serial numbers of your unit Record them in this manual in the space provided If the dealer knows exactly which unit you have he may be able to offer suggestions over the phone or save valuable time through knowledgeable preparation for the service call In C...

Reviews: