4

2. Insert tube end into remaining portion of compatible

fitting.

3. Solder with low--temperature (430

F) silver alloy solder.

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage or improper operation.
Wrap a wet cloth around rear of fitting to prevent damaging

factory--made joints.

CAUTION

!

4. Evacuate evaporator coil and tubing at condensing unit

service valves reclaiming refrigerant.

5. Operate system for 10 minutes.
6. Adjust charge to required superheat.

Copyright 2017 CAC / BDP

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: IM--CNPF--03

Replaces: IM--CNPF--02

Edition Date: 07/17

Summary of Contents for CNPFU Series

Page 1: ...These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions that will result in enha...

Page 2: ...ons A Mechanical Connection 1 Loosen lock nut on compatible fitting one turn Do not remove See Fig 2 LOCKNUT O RING RUBBER PLUG A86154 Fig 2 Compatible Fitting 2 Remove plug making sure O ring is in the groove inside compatible fitting 3 Cut tubing to correct length Insert tube into compatible fitting until it bottoms 4 Keep compatible fitting bottomed Tighten lock nut using backup wrench until it...

Page 3: ... drain unit requires service or water damage will occur NOTE For downflow electric furnace the secondary overflow drain connection must be installed to prevent possibility of water dripping onto live electrical components UNIT OR PROPERTY DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Failure to install trap can result in condensate flowing out of...

Page 4: ...ng to prevent damaging factory made joints CAUTION 4 Evacuate evaporator coil and tubing at condensing unit service valves reclaiming refrigerant 5 Operate system for 10 minutes 6 Adjust charge to required superheat Copyright 2017 CAC BDP S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligation...

Reviews: