4
5
CONTROL PADS ON THE DEHUMIDIFIER
Control panel(1)
Control panel(2)
3
1
2
5
Indicator lights
Power on indicator light(green)
Continuous operation on indicator light(green)
Bucket full indicator light(red)
Display
Shows the set % humidity level while setting, then shows
the 5% accuracy) room % humidity level.
Error Codes:
E1
- Humidity sensor error--Unplug the unit and plug
it back in. If error repeats, call for service.
E2
- Temperature sensor error-- Unplug the unit and
plug it back in. If error repeats, call for service.
Protect Codes:
P1
- Unit is defrosting-- Allow the unit to automatically
defrost. The portect will clear after the unit self defrosts.
P2
- Bucket is full or bucket is not in the right position--
Empty the bucket and replace in the right position.
6
POWER Pad
Press to turn the dehumidifier on and off.
7
Continue Pad
Select for the dehumidifier to operate
continuously for maximum dehumidification
until the bucket is full. The Humidity set
control pads cannot be used when
Continuous operation is on.Press this pad
again to cancel Continuous operation.
8
Humidity Set Control Pads
The humidity level can be set within a
range of 35%RH(Relative Humidity) to 80%
RH(Relative Humidity) in 5% increments.
For drier air, press the pad and set to a
lower percent value(%).
For damper air, press the pad and set to
a higher percent value(%).
Control pads
The control panel of the dehumidifier you purchased may be look like one of the following:
IDENTIFICATION OF PARTS
Identification of par ts
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
Auto Shut Off
The water level control switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position. When the setting humidity
is reached, the unit will be shut off automatically.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.The Auto Defrost indicator
light will glow.
Auto-Restart(on some models)
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
Auto Defrost
Power Cord
Air Outlet grille
Drain hose outlet (see page 7)
Air filter (behind the air intake grille)
Power Plug
Power cord band (Used only when storing the unit.)
Front
Rear
Control panel
Air intake grille
Water bucket
Handle
9
10
7
5
6
8
3
1
2
4
Fig.1
Fig.2
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
NOTE:
All the pictures in the manual are
for explanation purposes only.Your unit
may be slightly different.The actual shape
shall prevail.The operations and functions
are the same.
4
Full
Power
Full
Power
2
3
5
6
1
8
7
1
2
6
1
2
3
5
6
7
8
9
10
Con t.
Working
4
4
Dehumidify operation on indicator light(green)
Power
Summary of Contents for CDT-105E3
Page 7: ......