CONTROL  PADS  ON  THE  DEHUMIDIFIER

Control panel(1)

Control panel(2)

3

1

2

5

Indicator lights

Power on indicator light(green)

Continuous operation on indicator light(green)

Bucket full indicator light(red)

Display

Shows the set % humidity level while setting, then shows 
the 5% accuracy) room % humidity level.

Error Codes:

E1

- Humidity sensor error--Unplug the unit and plug 

it back in. If error repeats, call for service.

E2

- Temperature sensor error-- Unplug the unit and 

plug it back in. If error repeats, call for service.

Protect Codes:

P1

- Unit is defrosting-- Allow the unit to automatically

defrost. The portect will clear after the unit self defrosts.

P2

- Bucket is full or bucket is not in the right position-- 

Empty the bucket and replace in the right position.

6

POWER Pad

Press to turn the dehumidifier on and off.

7

Continue  Pad

Select for the dehumidifier to operate
continuously for maximum dehumidification
until the bucket is full. The Humidity set 
control pads cannot be used when 
Continuous operation is on.Press this pad 
again to cancel Continuous operation.

8

Humidity Set Control Pads

The humidity level can be set within a 
range of 35%RH(Relative Humidity) to 80%
RH(Relative Humidity) in 5% increments.
For drier air, press the      pad and set to a 
lower percent value(%).
For damper air, press the      pad and set to
a higher percent value(%).

Control pads

The control panel of the dehumidifier you purchased may be look like one of the following: 

IDENTIFICATION  OF  PARTS

Identification of  par ts

Other features 

Bucket Full Light

Glows when the bucket is ready to be 
emptied, or when the bucket is removed
or not replaced in the proper position.

Auto Shut Off

The water level control switch shuts off the
dehumidifier when the bucket  is full, or when 
the bucket is removed or not replaced in the 
proper position. When the setting humidity
is reached, the unit will be shut off automatically.

When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue to 
run until the frost disappears.The Auto Defrost indicator
light will glow.

Auto-Restart(on some models)

If the unit breaks off unexpectedly due to the power cut, 
it will restart with the previous function setting automa-
tically when the power resumes.

Auto Defrost

Power Cord

Air Outlet grille

Drain hose outlet (see page 7)

Air filter (behind the air intake grille)

Power Plug

Power cord band (Used only when storing the unit.)

Front

Rear

Control panel

Air intake grille

Water bucket

Handle

9

10

7

5

6

8

3

1

2

4

Fig.1

Fig.2

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart 
opertation in the first 3 minutes. This is to protect 
the unit. Operation will automatically start after 
3 minutes.

NOTE:

 

All the pictures in the manual are 

for explanation purposes only.Your unit 
may be slightly different.The actual shape 
shall prevail.The operations and functions 
are the same.
             

4

Full

Power

Full

Power

2

3

5

6

1

8

7

1

2

6

1

2

3

5

6

7

8

9

10

Con t.

Working

4

4

Dehumidify operation on indicator light(green)