5. INSTALLING YOUR CO ALARM:   
CAUTION: This alarm should be installed by a 

competent person.
The installation of this device should not be 

used as a substitute for proper installation, use 

and maintenance of fuel burning appliances, 

including appropriate ventilation and exhaust 

systems. 
It does not replace a smoke alarm.
Installation with screw and plug: 

Detach the alarm from the mounting base by twisting 

counter clockwise.

Use the mounting base to mark up horizontally the 

screw holes on the wall.

Attach the alarm by twisting clockwise.

Please note: The label in the product must not be 

removed as it contains important information regard-

ing the product.
6.

 

TEST FUNCTION:   

After installation and at least once per quarter, test 

your alarm to make sure it is operating correctly.

It is recommended to check visually every week if the 

green LED flashes correctly (every minute)
When the top button is pressed the alarm sounder 

will sound, and when the button is released, the 

alarm will make a self-test of the sensor and battery 

for approximately 9 seconds. During this delay the 

three LEDs will be flashed in sequence. The result 

of the test will be indicated after the test has been 

completed.  

If the test passes, the green LED will emit for 3 sec. 

If the test fails, a fault indication will be given (See 

section 11).
After the test function is performed, the alarm will 

need to recover for one minute before the next test 

can be done (to allow the sensor chamber to re-set-

tle after the test current is applied).
The alarm will also do a self-test every 24 hour and 

test the sensor for faulty sensor, drift or short circuit.
TIP: It is safe to cover the sound output hole with 

your finger during the testing to minimize the sound 

level emitted.
7.

 

OTHER INFORMATION:   

Do not paint the alarm. 
Disposal: Please dispose the product properly at the 

end of life. This is electronic waste which should be 

handled properly.
WARNING: Batteries shall not be exposed to exces-

sive heat such as shine, fire, or the like.  Note the 

local country regulations regarding installation.
WARNING: To prevent injury, this apparatus must be 

permanently fixed to the ceiling/wall in accordance 

with the installation instructions. 
The CE mark affixed to this product confirms its 

compliance with the European Directives which 

apply to the product. 

All Rights reserved: CAVIUS Aps assumes no re-

sponsibility for any errors, which may appear in this 

manual. Furthermore, CAVIUS Aps reserves the 

right to alter the hardware, software, and/or speci-

fications detailed herein at any time without notice, 

and CAVIUS Aps does not make any com mitment 

to update the information contained here in. All the 

trademarks listed herein are owned by their respec-

tive owners. Copyright © CAVIUS Aps.

Developed by CAVIUS Aps Julsøvej 16, DK-8600  

Manufactured in P.R.C.
Contact: CAVIUS Ltd, Edinburgh, Scotland, EH3 9DQ

Tel: +44(0)1506 896785, www.cavius.com

EN50291-1:2018

EN50291-2:2010 

www.cavius.com

400148 rev3

Mark up screw holes with a pen

Use the enclosed screws 

and plugs for installation

Peak ceiling

Minimum 30cm 

from peak

Minimum 30cm 

from wall

Wall

Ceiling

1 to 3m from fireplace

Wall