4-10
T-283
Table 4-3. Controller Configuration
Configuration
Description
Jumper
A.
High Reheat --- When this configuration is removed the unit will default
to high speed in reheat mode and in the low speed cool band. If not
removed heat reheat will default to low speed.
REMOVED
B.
High Vent --- When this configuration is removed the unit will default to
high speed in vent mode. If not removed vent mode will default to
low speed.
REMOVED
C.
NA
IN
D.
Reheat/Cycle --- When the reheat cycle configuration is removed the
unit is in reheat mode. The default configuration is cycle clutch
mode.
REMOVED
E.
Transducers --- When the transducer configuration is removed trans-
ducers will assumed to be present.
REMOVED
F.
NA
IN
G.
Unit Type --- SEPTA unit enabled with G in and H removed
IN
H.
Unit Type --- SEPTA unit enabled with G in and H removed
REMOVED
I.
NA
NA
J.
NA
IN
K.
Voltage --- When this configuration is removed the voltage selection
will be changed from 12 to 24V DC.
REMOVED
L.
NA
REMOVED
M.
NA
IN
N.
C/
F --- When this configuration is removed the display will show
temperatures in
F. When not removed the display will show tempera-
ture in
C.
REMOVED
O.
NA
IN
P.
NA
IN
Summary of Contents for CAPRI-280
Page 1: ...Model CAPRI 280 Septa T 283 Bus Air Conditioning Equipment...
Page 39: ...5 2 Figure 5 1 Electrical Wiring Schematic Diagram Drawing No 62 10112 00 Sheet 1 of 3...
Page 40: ...5 3 Figure 5 1 Electrical Wiring Schematic Diagram Drawing No 62 10112 00 Sheet 2 of 3...
Page 41: ...5 4 Figure 5 1 Electrical Wiring Schematic Diagram Drawing No 62 10112 00 Sheet 3 of 3...