Step 10
Once the proper brix has been achieved, turn the
handle “up” to allow product to flow to the mix tank.
Figure 33
Note:
The position of the handle on the syrup
sampling valve determines the direction of product
flow. The down position opens the syrup sampling
valve for collecting brix samples. The center position
shuts off the product flow. The up position directs
the flow of product to the freezing cylinder.
Step 11
Place a pail beneath the door spout. Open the draw
valve and drain the freezing cylinder to remove any
incorrectly brixed product. Close the draw valve.
Step 12
Press the PRIME (+ + +) key. Allow the liquid level
to fill to the prime plug hole.
Step 13
Repeat these steps for the other freezing
cylinders.
Step 14
To place the freezing cylinders in the AUTO mode,
press the AUTO (- ->) key for each freezing cylinder.
When the unit cycles off, the product will be at
serving viscosity.
Figure 34
Step 15
Close the illuminated display when complete.
Replace the panels and the hood, and attach with
screws. Install the front drip tray and the splash
shield on the front of the freezer.
120 Day Closing Procedure
We recommend that the machine be completely
disassembled and cleaned at least every 120 days
using the following procedures.
ALWAYS FOLLOW LOCAL HEALTH CODES
To disassemble the Model C302, the following items
will be needed:
S
Two cleaning pails
S
Necessary brushes (provided with freezer)
S
Cleaner
S
Single service towels