Unit Introduction

This  unit  is  a  small  packaged  gas  heat/electric  cooling  system  that

utilizes the comfort of gas heating packaged along with efficient electric

air conditioning. This unit uses Puron®, the environmentally balanced

refrigerant for cooling. 

Starting or Shutting Off Unit

NOTE: 

Your  combination  heating/cooling  unit  is  equipped  with  an

automatic direct spark ignition and power combustion blower.

To start unit gas heat:

Refer to 

Fig. 2

 for location of unit front access panel. Refer to 

Fig. 3

 for

location  of  gas  valve.  Refer  to 

Fig. 4

  while  proceeding  with  the

following steps.

1. Set  the  temperature  selector  on  room  thermostat  to  the  lowest

temperature setting and set system switch to HEAT.

2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the  control  access  panel  with  a 5/16-in.  nut driver.  (See

Fig. 2

.)

A14456

Fig. 2 – Unit Access Panel

5. Move  the  selector  switch  on  the  internal  gas  valve  to  the  OFF

position and wait 5 minutes.

6. Move  the  selector  switch  on  the  internal  gas  valve  to  the  ON

position.

7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.
10. Set  the  temperature  selector  on  room  thermostat  slightly  above

room  temperature  to  start  unit. The  induced-draft  combustion  air

fan will start. Main gas valve will open and main burners should

ignite  within  25  seconds.  If  the  burner  does  not  light  within  25

seconds,  the  ignition  module  will  go  into  a  Retry  Mode  after  a

period  of  approximately  20  seconds  (following  the  7-second

ignition period). If the burners do not light by the 4th ignition try of

the initial call for heat, there is a lockout.

11. Set the temperature selector on room thermostat to desired setting.

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Failure  to  follow  this  warning  could  result  in  personal  injury,  death

and/or property damage.

1. Do not turn off the electrical power to unit without first turning

off the gas supply.

2. Before  attempting to start  the gas  heating section,  familiarize

yourself with all the procedures that must be followed.

WARNING

!

FIRE, EXPLOSION HAZARD

Failure  to  follow  this  warning  could  result  in  personal  injury,  death,

and/or property damage.

Do not attempt to light by hand. Never attempt to manually light the

main burners on unit with a match, lighter, or any other flame. If the

electric  sparking  device  fails  to  light  the  main  burners,  refer  to  the

following  shutdown  procedures,  then  call  your  dealer  as  soon  as

possible.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury. 

When  removing  access  panels  or  performing  maintenance  functions

inside  your  unit,  be  aware  of  sharp  sheet  metal  parts  and  screws.

Although special care is taken to reduce sharp edges to a minimum, be

extremely  careful  and  wear  appropriate  protective  clothing,  safety

glasses and gloves when handling parts or reaching into the unit.

WARNING

!

FIRE AND EXPLOSION HAZARD

Failure  to  follow  this  warning  could  result  in  personal  injury,  death,

and/or property damage.

1. If the main burners fail to light, or the blower fails to start, shut

down gas heating section and call your dealer for service.

2. Never attempt to manually light the main burners on unit with a

match, lighter, or any other flame. If the electric sparking device

fails to light the main burners, refer to the following shutdown

procedures, then call your dealer as soon as possible.

Compressor
Access Panel

Control
Access
Panel

Blower
Access
Panel

Filter Access Panel
For Accessory FIlter
Rack

Summary of Contents for bryant Preferred 577E

Page 1: ...rred 15 and 16 SEER 2 Stage Packaged Air Conditioner and Gas Furnace System With Puron R 410A Refrigerant Single and Three Phase 2 5 Nominal Tons Sizes 24 60 Technician Name Phone Number Address Compa...

Page 2: ...roduct is used in or around the home or business that the dwelling be equipped with a CO Alarm s The Consumer Product Safety Commission recommends the use of CO Alarm s The CO Alarm s must be installe...

Page 3: ...rners do not light by the 4th ignition try of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting WARNING FIRE EXPLOSION ELECTRICAL SHOCK...

Page 4: ...with the following facts Cooling Mode With the SYSTEM control set to COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot day...

Page 5: ...following information is given to assist in changing filters used in these internal filter racks Filter kits are available as a purchased accessory or a factory installed option The same filter kit i...

Page 6: ...tions and designs without notice and without obligations 6 A13035 Fig 4 To Start Unit Gas Heat 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 460 VAC MODELS 72 ST...

Page 7: ...and designs without notice and without obligations 7 A13036 Fig 5 To Shut off Unit Gas Heat A09194 Fig 6 To Start Unit Electric Cooling 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP...

Page 8: ...Outdoor Fan The fan must be kept free of all obstructions to ensure proper cooling Contact your dealer for any required service Electrical Controls and Wiring Electrical controls are difficult to chec...

Page 9: ...this time Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation St...

Page 10: ...needed to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect temperature and pressure safety controls for damage X Inspect and clean if necessary burners a...

Reviews: