6
27 10 Q 19
8
4
3
Week of Year
Year of Manufacture
Unique Number
Place of Manufacture
MODEL NUMBER NOMENCLATURE
S
ERIAL NUMBER BREAKDOWN
Fig. 1 — 19XR,XRV Identification
a19-1969
8
H
Cooler Size†
10-12 (Frame 1)
15-17 (Frame 1)
20-22 (Frame 2)
30-32 (Frame 3)
35-37 (Frame 3)
40-42 (Frame 4)
45-47 (Frame 4)
50-54 (Frame 5)
5A-5C (Frame 5)**
55-59 (Frame 5)
5F-5H (Frame 5)**
5K-5R (Frame 5)††
5T-5Z (Frame 5)††
60-64 (Frame 6)
6K-6R (Frame 6)††
65-69 (Frame 6)
6T-6Z (Frame 6)††
70-74 (Frame 7)
7K-7R (Frame 7)††
75-79 (Frame 7)
7T-7Z (Frame 7)††
80-84 (Frame 8)
8K-8R (Frame 8)††
85-89 (Frame 8)
8T-8Z (Frame 8)††
Condenser Size†
10-12 (Frame 1)
15-17 (Frame 1)
20-22 (Frame 2)
30-32 (Frame 3)
35-37 (Frame 3)
40-42 (Frame 4)
45-47 (Frame 4)
50-54 (Frame 5)
55-59 (Frame 5)
60-64 (Frame 6)
65-69 (Frame 6)
70-74 (Frame 7)
75-79 (Frame 7)
80-84 (Frame 8)
85-89 (Frame 8)
Compressor Frame
2, 3, 4, 5 — Single-Stage
E — Two-Stage
Motor Code***
Motor Voltage Code
Code Volts-Phase-Hertz
60 — 200-3-60
61 — 230-3-60
62 — 380-3-60
63 — 416-3-60
64 — 460-3-60
65 — 575-3-60
66 — 2400-3-60
67 — 3300-3-60
68 — 4160-3-60
69 — 6900-3-60
50 — 230-3-50
52 — 400-3-50
53 — 3000-3-50
54 — 3300-3-50
55 — 6300-3-50
5A
5B
6A
6B
6C
—
—
—
—
—
10000-3-50
11000-3-50
11000-3-60
11000-3-60
13800-3-60
Special Order Indicator
– — Standard
S — Special Order
Description
19XR– — High Efficiency Semi-Hermetic
Centrifugal Liquid Chiller
19XRV — High Efficiency Semi-Hermetic
Centrifugal Liquid Chiller with
Unit-Mounted VFD
Impeller Diameter
UG
T* 64
19XR
–
52
51
3
Impeller Shroud
Motor Efficiency Code
Compressor Frame 2, 3, 4, 5
H — High Efficiency
S — Standard Efficiency
Gear Code
Compressor Frame E
A,B,C,D,E— A-E Gear Ratio
Compressor Frame 3, U Motor
R,S,T,U,V,W— R-W Gear Ratio
*
Digit 15 will refer to the Gear Code for the following models:
1. Digit 10 (Compressor Frame) is E
2. Digit 10 (Compressor Frame) is 3 and Digit 13 of the Motor Code is U.
†
Frame sizes 1 through 6 available on single-stage units only.
**
Refer to 19XR,XRV Computer Selection Program for details on these sizes.
†† Frame sizes with K-R and T-Z are with 1 in. OD evaporator tubing.
*** Refer to the 19XR,XRV Computer Selection Program for motor size details.
a19-2026
Summary of Contents for AquaEdge 19XR series
Page 69: ...69 Fig 33 19XR Leak Test Procedures a19 1625 ...
Page 154: ...154 Fig 64 Benshaw Inc Wye Delta Unit Mounted Starter Wiring Schematic Low Voltage a19 1873 ...
Page 161: ...161 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v ...
Page 162: ...162 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v cont ...
Page 186: ...186 APPENDIX B LEAD LAG WIRING 19XR Lead Lag Schematic Series Cooler Flow a19 1655 ...
Page 187: ...187 APPENDIX B LEAD LAG WIRING cont 19XR Lead Lag Schematic Parallel Cooler Flow a19 1717 ...