Fig. 6—24-V Control Circuit Connector

A93199

4

4

RH

R

Y

G

A

W

LLS

NC

TRANS

MIN 60VA

TO IFM LINE
VOLTAGE
POWER
SUPPLY

IFR

C

C

BLU

BRN

Y

COND UNIT

THERMOSTAT

SUBASE

RC

B

Y

1

Y

2

G

 

W

1

W

2

LEAVE JUMPER
ON SUBASE
(RH TO RC)

LLS

NC

TRANS
SEE NOTE 2

TO IFM LINE
VOLTAGE
POWER
SUPPLY

C

BLU

BRN

HC

1

HC

2

ADD JUMPER

R

Y

G

A

W

IFR

TO IFM LINE
VOLTAGE
POWER
SUPPLY

C

BLU

BRN

HC

NOTES: 1.   REFER TO UNIT LABEL WIRING DIAGRAM FOR 

WIRE COLORS.  IFR, IFM AND LLS ARE LOCATED
INDOORS ON HEATING-COOLING APPLICATIONS.
IF ACCESSORY IFR IS REQUIRED FOR COOLING-
ONLY APPLICATIONS, LOCATE IFR IN FAN COIL.

2.   N.E.C. CLASS 2, 24V CIRCUIT, MIN 40VA REQUIRED.

ARRANGEMENT A–COOLING ONLY

ARRANGEMENT C–1 TRANSFORMER;

COOLING AND 2-STAGE HEATING

C

– CONTACTOR

HC

– HEATING CONTROL

IFM

– INDOOR FAN MOTOR

LLS
NC

– NORMALLY CLOSED

– LIQUID LINE SOLENOID VALVE

TRANS – TRANSFORMER

IFR

TRANS
SEE NOTE 2

LLS

NC

ARRANGEMENT B – 1 TRANSFORMER;

COOLING AND 1-STAGE HEATING