29
80AWX- 80AWH
English
Installation
Power wiring diagram
Please refer to the Safety Information manual and to the
electrical scheme supplied with the unit.
Electrical installation must be according to fig. 15.
Description
80AW-065
80AW-115
M0
M3
M6
T6
M0
M3
M6
T6
T9
A
Power supply
outdoor unit,
backup heater,
booster heater
1pH - 230V
3ph - 400V
1pH - 230V
3ph - 400V
B Main breaker (field
supplied)
2 poles
4 poles
2 poles
4 poles
C
Outdoor unit
breaker (field
supplied)
2 poles, 16 A
2 poles, 25 A
D
Booster heater
breaker (field
supplied)*
2 poles, 16 A
2 poles, 16 A
Description
Cable
Type
80AW-065
80AW-115
M0
M3
M6
T6
M0
M3
M6
T6
T9
1 Outdoor unit
power supply cable H07 RN-F
3G x 2.5mm
2
3G x 4mm
2
2
Indoor unit
power supply and
communication
cable
H07 RN-F
3G x 1mm
2
3G x 1mm
2
3 Backup heater
power supply cable H07 RN-F
-
3G x
4mm
2
3G x
6mm
2
4G x
6mm
2
-
3G x
4mm
2
3G x
6mm
2
4G x
6mm
2
4G x
10mm
2
4 User interface
cable
FROH2R
4 x 0.75mm
2
4 x 0.75mm
2
5
Booster heater
power supply
cable*
H07 RN-F
3G x 4mm
2
3G x 4mm
2
6 Booster heater
activation cable
FROH2R
2 x 1mm
2
2 x 1mm
2
7 Sanitary hot water
sensor cable
FROH2R
2 x 0.5mm
2
2 x 0.5mm
2
8 Remote outdoor
sensor cable
FROH2R
2 x 0.5mm
2
2 x 0.5mm
2
* valid for domestic hot water tanks listed in paragraph Accessories
If the user interface is installed in zone, install it in a place which is representative of the room temperature. Avoid direct
contact or proximity with heat or cool sources.
Correct height installation is 1.5 m from the ground.
See electrical scheme.
Summary of Contents for 80AWH Series
Page 1: ...Controlmodule 80AWX 80AWH Installation Manual ...
Page 2: ...2 80AW1 80AW2 1 2 T 1 T 2 T 3 C C 1 C 2 C 3 1 2 3 7 6 M 4 5 1 2 2 3 4 5 5 ...
Page 3: ...3 80AW1 80AW2 3 4 i j k l m n o b c d e f g h a b c d e a p ...
Page 9: ...9 80AW1 80AW2 16 15 1 2 3 4 5 6 7 A B C D 8 2 ...
Page 10: ...10 80AW1 80AW2 17 18 2 3 2 3 ...
Page 12: ...12 80AW1 80AW2 21 Y2 G2 Rh Rc Y2 G2 Rh Rc J1 J8 A B J5 C ...