T-365
7–30
TP 1
- Not used in this application.
TP 2
- Enables the user to check if the high pressure switch (HPS) is open or closed.
TP 3
- Enables the user to check if the water pressure switch (WP) contact is open or closed.
TP 4
- Enables the user to check for power availability to the DUV contact TD.
TP 5
- Enables the user to check if the internal protectors for the evaporator fan motors (IP-EM1 or IP-EM2) are
open or closed.
TP 6 (IF EQUIPPED)
- Enables the user to check if the controller liquid injection valve relay (TQ) is open or closed.
TP 7
- Enables the user to check if the controller economizer solenoid valve relay (TS) is open or closed.
TP 8
- Not used in this application.
TP 9
- The chassis (unit frame) ground connection.
TP 10
- Enables the user to check if the heat termination thermostat (HTT) contact is open or closed.
Figure 7.21 Controller Section of the Control Box
7.24.3
Controller Programming Procedure
CAUTION
!
The unit must be OFF whenever a programming card is inserted or removed from the controller
programming port.
1. Turn unit OFF, via start-stop switch (ST).
2. Insert software/programming PCMCIA card containing the following (example) files into the programming/
):
menuDDMM.ml3, this file allows the user to select a file/program to upload into the controller.
cfYYMMDD.ml3, multi-configuration file.
3. Turn unit ON, via start-stop switch (ST).
Controller Software
Programming Port
Mounting Screw
Controller
Test
Points
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......
Page 173: ......