6.13 ABNORMAL TEMPERATURES
High discharge temperature
Condenser coil dirty
Condenser fan rotating backwards
Condenser fan inoperative
Refrigerant overcharge or noncondensibles
Discharge service valve partially closed
Open
Electronic expansion valve (EEV) control malfunction
Replace
Failed suction pressure transducer (SPT),
or evaporator pressure transducer (EPT)
Replace
Discharge temperature sensor drifting high
Replace
Failed economizer expansion valve, economizer coil,
or economizer solenoid valve
Replace
Plugged economizer expansion valve, economizer coil,
or economizer solenoid valve
Replace
Loose or insufficiently clamped sensor
Replace
6.14 ABNORMAL CURRENTS
Unit reads abnormal currents Current sensor wiring
Check
CONDITION
POSSIBLE CAUSE
REMEDY/
REFERENCE
SECTION