background image

Electrolux Cold Rooms

 -2/+2º - 3,1/6,1 m³

Electrolux cold rooms are available in a vast range of different sizes and functionalities. They are designed to 
work in tropical temper43ºC). The range consists of coolers (-2/+2ºC) with panels 60 mm in thickness, 
freezer cold rooms (-18/-20°C) with panels 100 mm in thickness and with built-in or remote refrigerating unit. 
The five models detailed on this sheet are cooler cold rooms with a usable volume of 3,1 to 6,1 cubic meters. 
Models come with panels and gas pre-charged cooling unit.

Shelving as accessory

CONSTRUCTION

• 

Very short assembly time. Expert 

refrigeration knowledge is not required 
for installation. 

• 

New vacuum injection technology 

which permits to have significant 
enhancement on the performances of the 
panels and high quality. 

• 

Panels are cladded inside and outside 

with anti-scratch prepainted galvinized 
steel. Polyurethane foam insulation. CFC 
and HCFC free. 

• 

Rounded internal and external corners. 

All edges are radiused. 

• 

Anti-slip walk-in floor.

• 

The fast-fit centering system allows 

perfect alignment of the panels. These 
new fasteners are made of high resistant 
composite materials and guarantee 
perfect grip of all components. 

• 

Airtight panels connection. All sides of 

panels have PVC gasket foamed in place 
to assure airtight and secure fitting. Any 
other sealing between panels on site is 
eliminated. 

• 

The refrigeration unit is mounted on a 

modular panel for easy installation and 
quick set-up of the cold room. All the 
refrigeration units are tropicalized (+43°C) 
and use R404A refrigerant and are 
supplied with a high/low temperature 
alarm.

• 

If the floor on which the cold rooms will 

be installed presents irregularities or 
unevenness up to 1 cm, then the surface 
of the floor should be levelled. 

 

PERFORMANCES

• 

Defrosting through heated gas with 

re-evaporation of defrosting water 
permits to reduce the total power 
installed, shorten defrosting time and 
limit the warming of the cold room. 

• 

All models are equipped with internal 

lighting (waterproof IP54) mounted on the 
refrigerating unit panel.

• 

The control panel includes: luminous 

ON/OFF switch, internal lighting switch, 
cold room functioning indicator, defrost 
cycle indicator, temperature and 
thermostat control with digital display.

• 

The right-hinged door is available as 

standard (left-hinged door on request) 
and constructed with smooth rounded 
profiles, cam-lift action hinges, airtight 
magnetic gasket and high insulation thus 
allowing to reduce energy and operating 
costs.

• 

Newly designed handle complete with 

lock and interior safety release to prevent 
entrapment when the door is accidentally 
locked from outside.

• 

HACCP monitoring is possible trough a 

serial port supplied on all models.

• 

Conform to ruling European safety and 

hygiene standards and 

H

 marked.

 

Summary of Contents for Cold Rooms 102028

Page 1: ...ght and secure fitting Any other sealing between panels on site is eliminated The refrigeration unit is mounted on a modular panel for easy installation and quick set up of the cold room All the refrigeration units are tropicalized 43 C and use R404A refrigerant and are supplied with a high low temperature alarm If the floor on which the cold rooms will be installed presents irregularities or unev...

Page 2: ...UM SHELV POLY TIERS COLDROOM 243X123 137100 ALUM SHELV POLY TIERS COLDROOM 203X123 137095 ALUM SHELV POLY TIERS COLDROOM 163X163 137091 ALUM SHELV POLY TIERS COLDROOM 163X123 137090 ALUM SHELV POLY TIERS COLDROOM 123X123 137108 ACCESSORIES Usable surface area m 2 00 2 66 2 50 2 99 Usable volume m 4 1 5 4 5 1 6 1 Power supply V phases Hz 220 230 V 1N 50 230 V 1N 50 230 V 1N 50 230 V 1N 50 230 V 1N ...

Page 3: ...ectrolux Cold Rooms 2 2º 3 1 6 1 m Internet http www electrolux com foodservice HFBA010 2010 05 28 Subject to change without notice EI Electrical connection 220 230 V 1N 50 LEGEND CR12N031S 102028 102028 ...

Page 4: ...Electrolux Cold Rooms 2 2º 3 1 6 1 m Internet http www electrolux com foodservice HFBA010 2010 05 28 Subject to change without notice EI Electrical connection 230 V 1N 50 LEGEND CR16N041S 102212 102212 ...

Page 5: ...Electrolux Cold Rooms 2 2º 3 1 6 1 m Internet http www electrolux com foodservice HFBA010 2010 05 28 Subject to change without notice EI Electrical connection 230 V 1N 50 LEGEND CR16N054S 102213 102213 ...

Page 6: ...Electrolux Cold Rooms 2 2º 3 1 6 1 m Internet http www electrolux com foodservice HFBA010 2010 05 28 Subject to change without notice EI Electrical connection 230 V 1N 50 LEGEND CR20N051S 102217 102217 ...

Page 7: ...Electrolux Cold Rooms 2 2º 3 1 6 1 m Internet http www electrolux com foodservice HFBA010 2010 05 28 Subject to change without notice EI Electrical connection 230 V 1N 50 LEGEND CR24N061S 102234 102234 ...

Reviews: