T-318
2
−
7
2.2 REFRIGERATION SYSTEM DATA
a. Compressor/Motor
Assembly
Number of Cylinders
6
Model
06DR
CFM
41
Weight (Dry)
118kg (260 lb)
Approved Oil
Castrol Icematic
Oil Charge degrees
3.6 liters (7.6 U.S. pints)
Oil Sight Glass
The oil level range, with the compressor off,
should be between the bottom and one-eighth
level of the sight glass.
b. Expansion Valve Superheat
Verify at -18
°
C
(0
°
F) container box
temperature
4.5 to 6.7
°
C (8 to 12
°
F)
c. Heater Termination Thermostat
Opens
54
°
(+/-)C = 130
°
(+/-)F
Closes
38
°
(+/-4)C = 100
°
(+/-7)F
d. High Pressure Switch
Cutout
25 (+/-1.0)kg/cm
= 350 (+/-10)psig
Cut-In
18 (+/-0.7)kg/cm
= 250 (+/-10)psig
WARNING
EXPLOSION HAZARD: Failure to follow this WARNING can result in death, serious personal injury
and / or property damage.
Never use air or gas mixtures containing oxygen (O
2
) for leak testing or operating the product.
Charge Only With R
−
134a: Refrigerant must conform to AHRI Standard 700 specification.
e. Refrigerant
R
−
134a
Conforming to AHRI standard 700
specifications.
f. Refrigerant Charge
Unit Configuration
Charge Requirements
−
R-134a
Water-Cooled
Condenser
4.9kg (10.75 lbs)
Receiver
4kg (8.75 lbs)
NOTE:
g. Fusible Plug*
Melting point
99
°
C = (210
°
F)
Torque*
6.2 to 6.9mkg (45 to 50ft-lbs)
h. Sight Glass/Moisture Indicator
Torque
8.9 to 9.7mkg (65 to 70ft-lbs)
i. Rupture Disc
Bursts at
35 +/-
5%kg/cm
= (500 +/-
5%psig)
Torque
(P/N 14-00215-03)
1.4 to 2mkg (10 to 15 ft-lbs)
j. Condenser Pressure
Transducer
Condenser Fan Starts
Condenser fan will start if condenser pressure is
greater than 14.06kg/cm
(200psig) OR the con-
denser fan is OFF for more than 60 seconds.
Condenser Fan Stops
Condenser fan will stop if condenser pressure is
less than 9.14kg/cm
(130psig) AND the con-
denser fan remains ON for at least 30 seconds.
k. Unit Weight
Refer to unit model number plate.
l. Water Pressure Switch
Cut-In
0.5 +/-0.2kg/cm
(7 +/-3psig)
Cutout
1.6 +/-0.4kg/cm
(22 +/-5psig)
m. Discharge Pressure
Regulating Valve
Factory Setting
32.7 +/-2.5kg/cm
(72 +/-5.5psig)
* Rupture Disc, part number 14 -00215 -04 may be installed as an alternate for the receiver mounted fusible plug.