![Carrier 69NT40-541-001 Operation And Service Download Page 29](http://html1.mh-extra.com/html/carrier/69nt40-541-001/69nt40-541-001_operation-and-service_2563733029.webp)
3–5
T-316
3.1.6
Water-Cooled Condenser Section
The water-cooled condenser section (
) consists of a water-cooled condenser, sight glass, quench
expansion valve, rupture disc, condenser pressure transducer, filter-drier, water couplings, and water pressure
switch. The water-cooled condenser replaces the standard unit receiver.
Figure 3.5 Water-Cooled Condenser Section
1. Sight Glass
2. Water-Cooled Condenser
3. Rupture Disc
4. Condenser Pressure Transducer
5. Quench Valve
6. Filter-Drier
7. Liquid Line Service Valve
8. Moisture/Liquid Indicator
9. Coupling (Water In)
10. Self Draining Coupling (Water Out)
11. Water Pressure Switch
- - - - -