58SP0A/58SP1A: Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
24
A03214
Fig. 38 – Horizontal Left Application - Vent Elbow Right then Up
A03218
Fig. 39 – Horizontal Right Application-Vent Elbow Right
A03215
Fig. 40 – Horizontal Left Application - Vent Elbow Up
A03216
Fig. 41 – Horizontal Left Application - Vent Elbow Right
A03219
Fig. 42 – Horizontal Right Application - Vent Elbow Left then Up
Venting Notes for
-
1. For common vent, vent connector sizing and vent material: United
States-use the NFGC.
2. Immediately increase to 5-in. (102 mm) or 6-in. (152 mm) vent
connector outside furnace casing when 5-in. (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use
Type B vent immediately after exiting the furnace, except when
factory-approved Downflow Vent Guard Kit is used in the
downflow position. See Product Data Sheet for accessory listing.
4. Type-B vent where required, refer to Note 1 above.
5. A 4-in.(102 mm) single-wall (26 ga. min.) vent must be used inside
furnace casing and when the factory-approved Downflow Vent
Guard Kit is used external to the furnace. See Product Data Sheet
for accessory listing.
6. Accessory Downflow Vent Guard Kit required in downflow
installations with lower vent configuration. See Product Data Sheet
for accessory listing.
7. Chimney Adapter Kit may be required for exterior masonry
chimney applications. Refer to Chimney Adapter Kit for sizing and
complete application details. See Product Data Sheet for accessory
listing.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant
sheet metal screws, spaced approximately 180° apart.
9. Secure all other single wall vent connector joints with (3) corrosion
resistant screws spaced approximately 120° apart. Secure Type-B
vent
connectors
per vent
connector
manufacturer’s
recommendations.
START-UP, ADJUSTMENT, AND SAFETY
CHECK
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
SEE NOTES: 1,2,4,7,8,9 on the page
following these figures
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
This furnace is equipped with manual reset limit switches in the gas
control area. The switches open and shut off power to the gas valve, if a
flame rollout or overheating condition occurs in the gas control area.
DO NOT bypass the switches. Correct problem before resetting the
switches.
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures