background image

58CTA/CTX

PERFORMANCE 80 TWO-STAGE 4-WAY

MULTIPOISE INDUCED-COMBUSTION FURNACE

Input Capacities: 45,000 thru 155,000 Btuh

Product Data

A04041

THE PERFORMANCE 80 GAS FURNACE

The 58CTA/CTX Two-Stage, 4-way Multipoise Gas Furnaces
offer unmatched comfort in their class with ComfortHeat

t

technology in an 80% AFUE gas furnace. You get the benefits of a
ComfortHeat

t

technology furnace: reduced drafts, reduced sound

levels, longer cycles, less temperature swings between cycles, and

less temperature differences between rooms. Its exclusive,
intelligent microprocessor control adapts to the heating needs of

the home by automatically adjusting high and low heat times to
maximize comfort. The 58CTA/CTX furnaces are approved for use

with natural or propane gas, and the 58CTX is approved for use in
Low NOx Air Quality Management Districts.

STANDARD FEATURES

S

ComfortHeat

t

Technology Intelligent microprocessor control

S

Two--stage heating with single-stage thermostat with patented
Adaptive Control Technology

S

Very low operating sound through low--stage operation and
QuieTech

t

system

SmartEvap

t

--Humidity control when using a Thermidistat

t

/

Infinity

t

control

Comfort Fan

t

adjustable constant fan speed from the

thermostat

S

High-Efficiency Media Filtration Cabinet included

S

Microprocessor based control center
LED diagnostics and self test feature
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow

S

4-way Multipoise furnace, 13 vent applications

S

Compact design -- only 33-1/3 in. (847 mm) tall

S

Power Heat

t

Igniter

S

Draft Safeguard switch to ensure proper furnace venting

S

Insulated blower compartment

S

Inner door for tighter sealing

S

HYBRID HEAT

r

Dual Fuel System compatible

S

All models are Chimney Friendly when used with accessory
vent kit

S

Twinning in Upflow, Downflow and Horizontal

S

Residential installations eligible for consumer financing through
the Retail Credit Program

Summary of Contents for 58CTA/CTX

Page 1: ...ology Intelligent microprocessor control S Two stage heating with single stage thermostat with patented Adaptive Control Technology S Very low operating sound through low stage operation and QuieTecht system SmartEvapt Humidity control when using a Thermidistatt Infinityt control Comfort Fant adjustable constant fan speed from the thermostat S High Efficiency Media Filtration Cabinet included S Mi...

Page 2: ...00 Btuh 08 800 CFf7 12 1200 CFM 14 1400 CFM 16 1600 CFM Input Capacity 20 2000 CFM 045 44 000 Btuh 110 110 000 Btuh 22 2200 CFM 070 66 000 Btuh 135 132 000 Btuh 090 88 000 Btuh 155 154 000 Btuh Series Number EFFICIENCY RATING CERTIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS Before purchasing this appliance read important energy cost and efficiency information available from ...

Page 3: ...TCH BLOWER AND MOTOR RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH FLAME SENSOR Elbow may be turned to a different position depending on type of installation A04138 NOTE The 58CTA CTX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion ...

Page 4: ... C Auto Changeover TP NAC TC NAC For use with 1 speed Heat Pump deg F C Auto Changeover TP NHP TC NHP For use with 2 speed Air Conditioner deg F C Auto Changeover TP NRH For use with multi use stage configurations deg F C Auto Changeover Temperature and Humidity control TP PRH THERMOSTAT PROGRAMMABLE For use with 1 speed Air Conditioner deg F C Auto Changeover 7 Day Programmable TP PAC For use wit...

Page 5: ...2UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X X X X X KGACA02015FC X X X Natural to Propane Conversion Kit KGANP4601ALL X X X X...

Page 6: ...75 1195 1265 1030 1580 1325 Cooling 895 1175 955 1240 1605 1385 1755 2005 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 2 2 3 3 3 4 4 4 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certi...

Page 7: ...2230 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 5 5 5 6 6 7 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M r...

Page 8: ...installations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit KGAVG0101DFG required in downflow installations with bottom vent configuration 7 ...

Page 9: ... 8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02066 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02067 58CTA CTX ...

Page 10: ... 1320 1160 1465 1380 1260 1120 1385 1300 1195 1065 1285 1220 1120 1005 1175 1115 1025 925 1055 990 915 810 895 830 710 630 645 600 565 510 090 16 Bottom or Side s High Med High Medium Med Low Low 2060 1710 1470 1260 1030 2000 1695 1475 1265 1025 1930 1665 1450 1245 1020 1835 1585 1390 1225 990 1755 1480 1335 1165 940 1620 1390 1230 1090 890 1490 1245 1120 995 810 1315 1110 1005 880 720 1115 955 85...

Page 11: ...05 1500 1295 1835 1640 1450 1265 1710 1550 1380 1210 1590 1465 1315 1150 1470 1360 1215 995 1335 1210 1005 865 1025 945 855 745 835 785 670 540 135 22 Bottom Only High Med High Med Low Low 2485 2195 1880 1640 2400 2150 1850 1635 2310 2090 1820 1615 2215 2000 1780 1585 2110 1920 1715 1530 2000 1825 1635 1465 1880 1720 1540 1370 1725 1565 1415 1255 1535 1405 1290 1150 1355 1255 1160 1040 Both Sides ...

Page 12: ...e use of both side inlets a combination of 1 side and the bottom or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM FURNACE SIZE A CABINET WIDTH IN mm D SUPPLY AIR WIDTH IN mm E RETURN AIR WIDTH IN mm F CENTER LINE TOP AND BOTTOM FLUE COLLAR IN mm FLUE COLLAR IN mm SHIP WT LB KG FILTER MEDIA CABINET IN mm 045 08 14 3 16 360 12 9 16 319 12 11 16 322 ...

Page 13: ...7 432 16 1 4 413 15 381 20 508 mm 21 533 20 1 4 514 19 483 24 610 mm 25 635 24 1 4 616 23 584 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 1 2 With Flanges Bent Out 23 1 8 Opening 5 3 4 C Opening with Flanges Bent In B 600 mm 594 mm 603 mm 146 mm 651 mm 622 mm 587 mm A00444 58CTA CTX 58CTA CTX ...

Page 14: ...14 A08471 58CTA CTX ...

Page 15: ... 2 15 14 090 14 115 60 1 127 104 8 2 34 10 3 15 14 090 16 115 60 1 127 104 9 9 28 8 5 15 14 090 20 115 60 1 127 104 12 9 34 10 3 20 12 110 12 115 60 1 127 104 8 2 34 10 3 15 14 110 16 115 60 1 127 104 10 1 28 8 5 15 14 110 22 115 60 1 127 104 13 7 32 9 7 20 12 135 16 115 60 1 127 104 10 2 27 8 2 15 14 135 22 115 60 1 127 104 14 5 30 9 1 20 12 155 20 115 60 1 127 104 15 0 29 8 8 20 12 Permissible l...

Page 16: ...f 030 in 76 mm thickness minimum pre painted galvanized steel Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe Heat Exchangers Heat exchangers shall be a 4 Pa...

Reviews: