FURNACE COMPONENTS

2

 

Heavy-duty blower circulates air across the heat
 exchanger to transfer heat into the home.

Access door to air filters and blower.

Air filters.

Unique silencer system eliminates combustion 
noise.

Return-air plenum.

Stainless steel combustion chamber.

Heat exchanger designed and shaped to efficient-
ly
transfer heat from furnace into the home.

Supply-air plenum.

Fully insulated internal walls minimize heat loss.

High limit control prevents overtemperature.

Manual switch allows user control of constant 
low-speed blower operation.

Adjustable electronic fan timer control (inside) 
with low voltage electrical terminal strip for easy 
connection of thermostat, cooling control, elec-
tronic air cleaner, and humidifier.

Aesthetic removable cabinet hides and protects 
burner and controls.

High-performance oil burner.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Summary of Contents for 58CLA

Page 1: ...rvice must be performed by a qualified installer service agency or the fuel supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not use this furnace if any part has been under water Immediately call a qualified service techni cian to inspect the furnace and to replace any part of the co...

Page 2: ...day s homeowner can make Your new furnace is truly a triumph of technology in home heating A unique silencer within the heat exchanger insulated cabinet and rubber blower mounts make it among the quietest units on the mar ket The combustion chamber is stainless steel for long life and it heats up quickly resulting in higher energy efficiency With only minimal care your new furnace will deliver man...

Page 3: ...at exchanger designed and shaped to efficient ly transfer heat from furnace into the home Supply air plenum Fully insulated internal walls minimize heat loss High limit control prevents overtemperature Manual switch allows user control of constant low speed blower operation Adjustable electronic fan timer control inside with low voltage electrical terminal strip for easy connection of thermostat c...

Page 4: ...ting equipment Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters All other operations must be performed by trained service personnel Observe safety precautions in this manual on tags and on labels attached to the furnace and other safety precautions that may apply Recognize safety information This is the safety alert symbol When you see this sym...

Page 5: ... on the blower after 60 sec Fan on control is not adjust able The air moved over the heat exchanger by the blower is warmed and passes through the ducts to the room registers This unit is equipped with a continuous ignition control If the main burner does not ignite within 30 sec from the call for heat the control will lock out The red button on top of the control must be depressed for 3 sec in or...

Page 6: ...h proper maintenance and care your furnace will operate economically and dependably Instructions for basic maintenance follow However before beginning maintenance follow these safety precautions FILTERING OUT TROUBLE Dirty air filters will cause a loss of airflow in your duct system When excessive loss of airflow occurs the fur nace may cycle on its safety controls If this condition is left unatte...

Page 7: ...ter size FURNACE AIR FILTERTABLE If you have replaced the factory provided disposable filters with permanent washable filters they may be cleaned if they are dirty Wash filters in a sink bathtub or outside with a garden hose Always use cold tap water A mild liquid detergent may be used if neces sary Spray water through filter in the opposite direc tion of airflow Allow filter to dry 6 Reinstall cl...

Page 8: ...amine the physical support of the furnace Support should be sound with no cracks sagging gaps etc around the base Check furnace for any obvious signs of deterioration BEFORE YOU REQUEST A SERVICE CALL If your furnace is not operating or not performing properly you may save the expense of a service call by checking a few things yourself before calling for service FOR INSUFFICIENT AIRFLOW Check for ...

Reviews: