The operation and care of your unit is simple and easy. By fol-
lowing these operating and maintenance procedures, you can
expect to receive better, longer, and more reliable service from
your new appliance.

 

HERE ARE A FEW DO’S AND DO NOT’S

 

• 

 

DO

 

 

 

become familiar with the instructions.

 

• 

 

DO 

 

use filters. Check them periodically and make sure that

they are clean.

 

• 

 

DO 

 

check to see that your home has adequate insulation,

weatherstripping, caulking, and storm windows. Eliminating in-
filtration of outside air and drafts can save up to 40% of your
fuel bill.

 

• 

 

DO NOT

 

 

 

waste fuel by setting your thermostat too high. En-

ergy conservation experts recommend daytime thermostat set-
ting of 68

 

°

 

 F, with a lower setting at night.

 

• 

 

DO NOT

 

 

 

turn off the furnace when you expect to be away

for more than a day. Instead, lower the thermostat setting by a
few degrees. You can then restore normal comfort level quickly
and save fuel too.

 

• 

 

DO NOT

 

 

 

block registers with furniture.

 

• 

 

DO NOT

 

 

 

put a lamp, TV, or radio too near your thermostat.

This will cause it to give a false reading.

 

Here’s How Your Heating System Works

 

The furnace operates automatically. It is controlled by a ther-
mostat which you set at the temperature most comfortable to
you. When the inside temperature drops below this setting,
your thermostat will turn on the heating system.

When the thermostat calls for heat, power from the transformer
energizes the fan control board. The fan control energizes the
ignition control. The ignition control will light the burner au-
tomatically.

 

CAUTION

 

The ability to properly perform maintenance on
this equipment requires certain mechanical skills
and tools. If you are at all uncertain, contact your
dealer for qualified maintenance and service.

!

 

The electronic fan control will automatically turn on the
blower after 30 sec. Fan on control is not adjustable. The air
moved over the heat exchanger by the blower is warmed and
passes through the ducts to the room registers.

When the thermostat is satisfied, the circuit is de-energized and
the primary control shuts off the burner. The blower continues
to run until the selectable fan off time period has expired.

The heat sensing switch performs as the furnace high temper-
ature limit switch. If the furnace overheats for any reason, the
limit switch opens, breaking the circuit to the burner. The
blower motor will be energized and as the unit cools the limit
switch will close. This will relight the burner but unless the
overheating condition is corrected, the furnace will continue to
cycle on limit.

This unit is equipped with an interrupted ignition electronic
control. If the main burner does not ignite within 30 sec from
the call for heat, the control will go into lockout. The red button
on top of the control must be depressed for 3 sec in order to
reset the control. The control CANNOT be reset from the room
thermostat.

 

HEATING

 

Preparing Furnace For Operation

 

Before attempting to put your furnace into operation for the
heating season, you should perform the following procedures

 

.

 

1. Open all warm air registers and make sure that all return air

grills are unobstructed.

2. If a humidifier is installed with your system, open the water

supply valve.

3. Set the thermostat to its lowest setting.

4. Turn on electric power to the furnace.

5. Open the oil supply valve.

6. Check all connections to ensure there are no leaks.

 

WARNING

 

If you do not follow these instructions exactly, a
fire or explosion may result causing property
damage, personal injury, or loss of life.

!

Summary of Contents for 58BGA

Page 1: ...NUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL FIRED FURNACE NOTE TO INSTALLER THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER HEATING COOLING O I L F U R N A C E 58BGA 58BLA 58BMA 58BTA Thi d t t d ith F M k 4 0 4 ...

Page 2: ...ISE INSTALLATION DATA Date Installed Dealer Name Address City State Zip Telephone FURNACE Product No Model No Serial No 2 58BLA LOW BOY 4 58BTA UPFLOW HORIZONTAL SPLIT SYSTEM Product No Model No Serial No INDOOR COIL Product No Model No Serial No ...

Page 3: ...EACHES WAXES OR OTHER CLEANING COMPOUNDS PLASTIC OR PLAS TIC CONTAINERS GASOLINE KEROSENE CIGARETTE LIGHTER FLUID DRY CLEANING FLUIDS OR PAINTING COMPOUNDS FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration ser vice or maintenance can cause injury or property damage Re...

Page 4: ... all uncertain contact your dealer for qualified maintenance and service The electronic fan control will automatically turn on the blower after 30 sec Fan on control is not adjustable The air moved over the heat exchanger by the blower is warmed and passes through the ducts to the room registers When the thermostat is satisfied the circuit is de energized and the primary control shuts off the burn...

Page 5: ...ype electronic ignition system DO NOT ATTEMPT TO LIGHT WITH A MATCH DANGER HIGH VOLTAGE AT IGNITOR Filters A filter is supplied with the furnace except 58BGA It is NECESSARY THAT ALL FURNACES BE EQUIPPED WITH A FILTER If a different type of filter is used it must be an equivalent high airflow capacity Keeping Filters Clean As a homeowner this is your most important responsibility A dirty filter re...

Page 6: ...alled in an insulated space must be kept free and clear of insulating materials After the furnace is installed or whenever addi tional insulation is added check that all combus tion air intakes are free and clear and that all clearance dimensions are maintained INSULAT ING MATERIALS MAY BE COMBUSTIBLE WARNING Do not use this furnace if any part has been under water Immediately call a qualified ser...

Reviews: