SPLIT SYSTEM AIR CONDITIONER

53G100HF/53G150HF/53G225HF-1/53G250HF-1
53G100HP/53G150HP/53G250HP-1

OUTDOOR UNIT

38G100HF/38G150HF/38G100HP/38G150HP/

38G225HF-1/38G250HF-1/38G250HP-1

Carrier

 Corporation

P/N:42QG8V5404B

INDOOR UNIT

42G100HF/42G150HF/42G100HP/42G150HP/

42G225HF-1/42G250HF-1/42G250HP-1

42QG8V5404B(O/M-P)

2004.7.7, 2:42 PM

30-31

Summary of Contents for 53G100HF

Page 1: ...G225HF 1 53G250HF 1 53G100HP 53G150HP 53G250HP 1 OUTDOOR UNIT 38G100HF 38G150HF 38G100HP 38G150HP 38G225HF 1 38G250HF 1 38G250HP 1 Carrier Corporation P N 42QG8V5404B INDOOR UNIT 42G100HF 42G150HF 42G100HP 42G150HP 42G225HF 1 42G250HF 1 42G250HP 1 42QG8V5404B O M P 2004 7 7 2 42 PM 30 31 ...

Page 2: ...chno logical features your unit offers Moreover it contains vital information about maintenance service and economical operation Take the next few minutes to discover for yourself how to get the most in personal comfort and economical operation from your new Carrier room air conditioner OWNER S MANUAL PRECAUTIONS BEFORE OPERATION UNIT DESCRIPTION REMOTE CONTROL DESCRIPTION REMOTE CONTROL PREPARATI...

Page 3: ... result in leakage or electric shock Do not use the power cord as a means of turning off the unit Before performing service or maintenance operations on the system turn off the main power of the unit Electric shock can cause personal injury WARNING Do not use flammable sprays near the unit The unit can be damaged by gasoline benzene thinners insecticides and other chemical agents When unplugging t...

Page 4: ...e damage Set a comfortable temperature Very low or very high temperature setting consider ably increase power consumption To circulate the room air only operate at the FAN mode In summer if possible prevent direct sunlight from entering the room draw curtains or blinds Use the timer correctly to maintain comfort conditions Please read this owner s manual carefully before operating the unit It cont...

Page 5: ... on by the remote control a green light will be displayed TIMER Orange When the unit is in reservation mode an orange light will be displayed EMERGENCY button Can be used when the remote control is lost or inoperative TEST button Is only used by service men to test the unit operation For the usage of EMERGENCY and TEST buttons refer to EMERGENCY AND TEST OPERATION p 21 UNIT DESCRIPTION Indoor Unit...

Page 6: ...ess this button the unit will begin operation Press the button again and operation stops You can hear a receiving beep If you press this button immediately after turning off the unit the compressor will not operate for 3 minutes to prevent overloading TEMPERATURE SETTING BUTTONS If you set the desired room temperature then the unit will maintain the room temperature as set In COOL mode if the room...

Page 7: ...tment for some models NOTE Replacing Batteries Setting CurrentTime NOTE This function must only be performed by qualified service personnel When two units are used in the same room you can match the address of the remote control to that of the unit Remove the lid of the battery case Assign the address switch of one remote control as B Press the RST button with a sharp object Turn off the unit and ...

Page 8: ...ioner may not work properly Draw the curtains to avoid direct sunlight A mounting bracket for the remote control is supplied with the unit Install the mounting bracket on the wall 30cm below the receiver of the unit Automatic operation means that the air conditioner operates automatically by selecting the COOL or HEAT mode and automatically changes the fan speed according to the indoor condition t...

Page 9: ... is maintained at the set temperature 1 2 3 4 5 6 ON OFF button Press this button and the AUTO operation is indicated A receiving beep is heard The green UNIT on lamp of the indoor unit display illuminates MODE button Press this button to select the desired operation mode AUTO DRY COOL FAN HEAT FAN SPEED button Press this button to select the desired fan speed AUTO LOW MED HIGH TEMP button Press t...

Page 10: ... same condition Reserve the OFF Timer at 10 30 P M during operation Reserve the ON Timer at 7 30 A M When you want to start operation at 5 30 P M and stop at 10 30 P M everyday with the same operating condition Reserve the ON Timer at 5 30 P M Reserve the OFF Timer at 10 30 P M Press the EVERYDAY button and RESERV button NOTE Refer to pp 15 16 for the setting method and refer to p 18 for the cance...

Page 11: ...EDURE PROCEDURE If you want to stop the operation after 3 hours from now Press the SLEEP button 3 times 3 hr will be displayed and the signal will be flashing After 5 seconds the stopping time will be displayed The unit operates in sleep mode for 3 hours and will switch off at the end of the 3 hours To change the reserved time or to cancel press the SLEEP Button again 1 hr 2 hr 3 hr 7 hr 9 hr Canc...

Page 12: ...ards the occupants for a long period of time Do not adjust the flap by the hand during SWING operation because it may damage the air swing mechanism DISCHARGEAIR LOUVER CONTROL Up and Down Control HANDLE CLOSE 햲 햳 햴 햵 햶 햷 Fixed COOL 햳 햷 Auto Position HEAT 햲 햳 햴 햵 햶 햷 Swing Range COOL HEAT Test Operation This operation is used for checking after unit installation Press the TEST button Press the TES...

Page 13: ... 53G225HF 1 53G250HF 1 HP 1 When heating operation starts hot air delivery might be delayed due to a warm up period Minimum Operation Time In normal operation there is a minimum operation time of 3 minutes between compressor turning on and turning off Heating Features When the unit starts in the heating mode there will be a preheating period before the unit is ready to deliver warm air When the ou...

Page 14: ...and no air comes from the unit It indicates malfunction of the unit and the compressor will stop operating A creaking noise can sometimes be heard during operation or when the unit turns on This is the sound of plastic expanding due to an abrupt temperature change Refreshing the optional Photo catalyst filter Washing the Front Panel NOTE Turn off the unit and pull out the power plug Clean the air ...

Page 15: ...ower is resumed Does the UNIT ON lamp flash on and off Call your service representative Is the voltage too low Confirm the available voltage Is the filter blocked with dust Clean the air filter Has the temperature been set properly Check and reset it if necessary Are the windows or doors open Close the windows and doors Is anything obstructing the outdoor unit Remove the obstruction Is the fan spe...