Air Filters

The air filter(s) should be checked every 3 or 4 weeks  and changed or

cleaned whenever it becomes dirty. Dirty filters produce excessive stress

on the blower motor and can cause the motor to overheat and shut down. 
This unit must have air filters in place before it can be operated. These

filters can be located in one of at least two places. In many applications,

the installer will provide return air filter grilles mounted on the wall or

ceiling of the conditioned structure. In the instance of filter grilles, the

filters can simply be removed from the grille and replaced.

Table 1

 indicates the correct indoor filter size for your unit. 

If  you  have  difficulty  locating  your  air  filter(s)  or  have  questions

concerning  proper  filter  maintenance,  contact  your  dealer  for

instructions. When replacing filters, always use the same size and type of

filter that was supplied, originally, by the installer.

Fans and Fan Motors

Periodically  check  the  condition  of  fan  wheels  and  housings  and

fan-motor shaft bearings. No lubrication of condenser-or evaporator-fan

bearings or motors is required or recommended.

Indoor and Outdoor Coils

Cleaning of the coils should only be done by qualified service personnel.

Contact your dealer for the required annual maintenance.

Condensate Drain

The drain pan and condensate drain line should be checked and cleaned

at the same time the cooling coils are checked by your dealer.

Compressor

All  compressors  are  hermetically  sealed  and  do  not  require  periodic

maintenance.

Condenser Fan

The fan must be kept free of all obstructions to ensure proper cooling.

Contact your dealer for any required service.

Electrical Controls and Wiring

Electrical controls are difficult to check without proper instrumentation.

If there are any discrepancies in the operating cycle, contact your local

dealer and request service.

Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the proper

equipment. If inadequate cooling is suspected, contact your local dealer

for service.

Unit Panels

After  performing  any  maintenance  or  service  on  the  unit,  be  sure  all

panels are fastened securely in place to prevent rain from entering unit

cabinet and to prevent disruption of the correct unit airflow pattern.

Regular Dealer Maintenance (Also refer to 

Table 2

)

In addition to the type of routine maintenance you might be willing to

perform, your unit should be inspected regularly by a properly trained

service technician. An inspection (preferably each year) should include

the following:

1. Inspection and, if required, cleaning of the indoor coil condensate

drain.

2. Inspection and, if required, cleaning of the evaporator drain pan.
3. Inspection and cleaning of blower wheel housing and motor.
4. Inspection  of  all  supply-air  and  return-air  ducts  for  leaks,

obstructions, and insulation integrity. Any problems found should

be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps, etc., exist

which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to ensure proper

connection.

8. Inspection  for  leaks  in  the  refrigerant  circuit.  Pressure-check  to

determine appropriate refrigerant charge.

9. Operational  check  of  the  unit  to  determine  working  conditions.

Repair or adjustment should be made at this time.

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT 

HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

1. TURN  OFF  ELECTRICAL  POWER  TO  YOUR  UNIT

BEFORE SERVICING OR PERFORMING MAINTENANCE.

2. When  removing  access  panels  or  performing  maintenance

functions inside your unit, be aware of sharp sheet metal parts

and  screws.  Although  special  care  is  taken  to  reduce  sharp

edges to a minimum, be extremely careful when handling parts

or  reaching  into  the  unit.  Wear  safety  glasses,  gloves    and

appropriate protective clothing.

Table 1 – Indoor Air Filter Data

Unit Size

Filter Size

024

20x20x1 (508x508x25 mm)

030

20x24x1 (508x610x25 mm)

036-042

24x30x1 (610x762x25 mm)

048-060

24x36x1 (610x914x25 mm)

CAUTION

!

UNIT OPERATION HAZARD

Failure to follow this caution may result in property damage.

Never operate your  unit  without  filters  in  place. An accumulation  of

dust and lint on internal parts of your unit can cause loss of efficiency

and blower motor and/or compressor damage.

WARNING

!

PERSONAL INJURY AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

Do not insert sticks, screwdrivers, or any other object into revolving fan

blades. 

WARNING

!

EXPLOSION, BURN AND ENVIRONMENTAL HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

System  under  pressure.  Relieve  pressure  and  recover  all  refrigerant

before  system  repair  or  final  unit  disposal.  Use  all  service  ports and

open all flow-control devices, including solenoid valves.

Reviews: