Table 2 – Maintenance Checklist

Monthly maintenance items and outdoor unit rinsing may be performed by the consumer.  All other maintenance items and all service work must be

performed by a qualified service technician.  Read all Warning labels.

Description of Maintenance

Recommended Interval

Consumer specific:

Monthly

Annual

Inspect, clean, or replace air filter if filter is located indoors in return air duct.

X

Clear away debris and vegetation near unit.

X

Dealer specific:

Inspect cabinet and basepan for damage.  Replace panels, gaskets, and other components that are damaged or severely 

rusted.  Make sure precipitation has not  entered indoor section of unit.

X

Inspect electrical disconnect for proper function.  Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections.  Inspect and perform functional test of equipment as 

needed to ensure proper function.  Repair or replace damaged or overheated components and wiring.

X

Inspect electric heater, if installed.  Check for signs of overheating of elements, controls, and wiring.  Make sure heater 

elements are not broken or electically shorted.

X

Check refrigerant system subcooling and/or superheat  (system dependent).

X

Inspect inside of unit.  Clean if debris is present.

X

Inspect condenser coil.  Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect condenser motor and fan for damage.  Make sure fan spins freely.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect evaporator coil.  Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan and drain lines (more frequent maintenance may be required in humid climates).

X

Inspect airflow system (ductwork).  Check for leaks and repair as needed.

X

Notes:

1. The above list may not include all maintenance items.  Inspection intervals may vary depending on climate and operating hours.  Consult your HVAC dealer about a service 

contract for seasonal inspections.

2. Do not use harsh chemicals or high pressure water on coils.  More frequent rinsing is required for units near a sea coast.

Summary of Contents for 50ZHC

Page 1: ... R 410A Refrigerant Single Phase 2 to 5 Nominal Tons Sizes 024 060 Technician Name Phone Number Address Company Name Date Installed NOTE TO EQUIPMENT OWNER For your convience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance o...

Page 2: ... is designed to automatically melt the ice When in this defrost cycle it is normal for steam or fog to rise from the outdoor unit and for water to drain from the outside of unit Do not be alarmed To start the unit 1 Turn on the electrical power supply to unit 2 Set MODE control to desired mode and select temperature To shut off unit NOTE If the unit is being shut down because of a malfunction call...

Page 3: ...otor and can cause the motor to overheat and shut down This unit must have an air filter in place before it can be operated These filters should be located in at least one of two places In many applications the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure In the instance of filter grilles the filters can simply be removed from the gri...

Page 4: ...me Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation Start up and Service Instructions Warranty Certificate Your unit has a limited warranty Be sure to read the warranty carefully to determine the coverage for your unit Before you call for service check for seve...

Page 5: ...eded to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect electric heater if installed Check for signs of overheating of elements controls and wiring Make sure heater elements are not broken or electically shorted X Check refrigerant system subcooling and or superheat system dependent X Inspect inside of unit Clean if debris is present X Inspect condens...

Page 6: ... reserved Edition Date 08 20 Catalog No OM50ZHC 04 Replaces OM50ZHC 03 50ZHC Owner s Information Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 6 ...

Reviews: