background image

1

50GL---A

Single---Packaged 50Hz, CE Air Conditioner System

with Puron

R

(R---410A) Refrigerant

7---14 kW (24---48)

Product Data

A09042

Fig. 1 -- Unit 50GL--A

Single--Packaged Products with Energy--Saving Features and

Puron

R

refrigerant.

S

7--14 kW

S

Multi--Speed High Efficiency Blower--Standard

S

Low Sound Levels

FEATURES/BENEFITS

One--piece cooling unit with optional electric heater, low sound
levels, easy installation, low maintenance, and dependable

performance.

Puron Environmentally Sound Refrigerant

is Carrier’s unique

refrigerant designed to help protect the environment. Puron is an

HFC refrigerant which does not contain chlorine that can harm the
ozone layer. Puron refrigerant is in service in millions of systems

proving highly reliable, environmentally sound performance.

Easy Installation

Factory--assembled package is a compact, fully self--contained,

electric cooling unit that is prewired, pre--piped, and pre--charged
for minimum installation expense. These units are available in a

variety of standard cooling sizes with voltage options to meet

residential and light commercial requirements. Units are
lightweight and install easily on a rooftop or at ground level. The

high tech composite base eliminates rust problems associated with
ground level applications.

Innovative Unit Base Design

On the inside a high--tech composite material will not rust and

incorporates a sloped drain pan which improves drainage and helps

inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.

Convertible duct configuration

Unit is designed for use in either downflow or horizontal

applications. Each unit can be

converted from horizontal to

downflow and includes horizontal duct covers. Downflow
operation is provided in the field to allow vertical ductwork

connections. The basepan seals on the bottom openings to ensure a
positive seal in the vertical airflow mode.

Efficient operation High--efficiency design

offers capacities of 7

to 14 kW. (See page 4.)

Durable, dependable components
Scroll Compressors

are designed for high efficiency. Each

compressor is hermetically sealed against contamination to help

promote longer life and dependable operation. Each compressor

also has vibration isolation to provide quieter operation. All
compressors have internal high pressure and overcurrent

protection.

ECM Motor

is standard on all 50GL--A models.

Direct--drive PSC (Permanent Split Capacitor) condenser--fan

motors

are designed to help reduce energy consumption and

provide for cooing operation down to 40

_

F (4.4

_

C) outdoor

temperature. Motormaster

r

II low ambient kit is available as a

field--installed accessory.

Refrigerant system

is designed to provide dependability. Liquid

filter driers are used to promote clean, unrestricted operation. Each

unit leaves the factory with a full refrigerant charge. Refrigerant

service connections make checking operating pressures easier.

High and Low Pressure Switches

provide added reliability for the

compressor.

Indoor and Outdoor coils

are computer--designed for optimum

heat transfer and efficiency. The indoor coil is fabricated from

copper tube and aluminum fins and is located inside the unit for
protection against damage. The outdoor coil is internally mounted

on the top tier of the unit.

Low sound ratings

ensure a quiet indoor and outdoor

environment with sound ratings as low as 75dBA. (See Page 4.)

Easy to service cabinets

provide easy 3 panel accessibility to

serviceable components during maintenance and installation. The

basepan with integrated drain pan provides easy ground level
installation with a mounting pad. A nesting feature ensures a

positive basepan to roof curb seal when the unit is roof mounted. A
convenient 3/4--in. (19.1 mm) wide perimeter flange makes frame

mounting on a rooftop easy.

Standard horizontal metal duct covers

with insulation come

with the unit and cover the horizontal duct openings. These can be

left in place if the units are converted to downflow.

Cabinets

are constructed of heavy duty, phosphated, zinc--coated

prepainted steel capable of withstanding 500 hours in salt spray.

Interior surfaces of the evaporator/heat exchanger compartment are
insulated with cleanable semi--rigid insulation board, which keeps

the conditioned air from being affected by the outdoor ambient
temperature and provides improved indoor air quality. (Conforms

to American Society of Heating, Refrigeration and

Air

Conditioning Engineers No. 62P.) The sloped drain pan minimizes
standing water in the drain. An external drain is provided.

Summary of Contents for 50GL-A

Page 1: ...e longer life and dependable operation Each compressor also has vibration isolation to provide quieter operation All compressors have internal high pressure and overcurrent protection ECM Motor is sta...

Page 2: ...IPING AND WIRING 17 APPLICATION DATA 17 ELECTRICAL DATA 18 TYPICAL WIRING SCHEMATICS 19 CONTROLS 20 GUIDE SPECIFICATIONS 21 22 MODEL NUMBER NOMENCLATURE 50GL E Type of Unit 50GL Single Packaged Air Co...

Page 3: ...culating fan heat Ratings are based on Cooling Standard 80 F 26 7_C db 67 F wb 19 4_C indoor entering air temperature and 95 F db 35_C outdoor entering air temperature 2 Before purchasing this applian...

Page 4: ...BLOWER Nominal Cooling Airflow Cfm Nominal Cooling Airflow L s Wheel Size in Wheel Size cm Motor HP Motor kW 800 1000 1200 1600 800 378 10x10 25 4x25 4 1 4 186 1000 472 10x10 25 4x25 4 1 2 373 1200 56...

Page 5: ...justable damper blade for up to 25 outdoor air X Square to Round Duct Transition Kit Square to Round Duct Transition Kit enable 24 48 size units to be fitted to 14 in 356 mm round ductwork X Time Guar...

Page 6: ...6 UNIT DIMENSIONS 50GL A24 36 A09465 50GL A...

Page 7: ...7 UNIT DIMENSIONS 50GL A48 A09466 50GL A...

Page 8: ...mm B small common curb IN mm B large curb IN mm C IN mm D IN mm E IN mm F IN mm G IN mm H IN mm Small or Large CPRFCURB010A00 11 279 10 254 14 356 16 406 47 8 1214 32 4 822 2 7 69 30 6 778 46 1 1170...

Page 9: ...total capacity of 12 5 kW and a SHC of 9 1 kW Calculate SHC correction if required using Note 3 of Net Cooling Capacities Table 3 Select electric heat The required heating capacity is 6 4 kW 22 000 Bt...

Page 10: ...2 5 1 4 0 6 5 5 4 4 0 kW 2 0 2 1 2 1 2 1 2 2 2 2 2 2 2 3 2 3 35 TC 6 0 6 8 7 5 6 2 6 9 7 6 6 4 6 9 7 6 SHC 5 6 4 7 3 8 5 9 5 0 3 9 6 1 5 2 3 9 kW 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 5 41 TC 5 6 6 3 7 1...

Page 11: ...8 7 8 6 4 5 0 8 1 6 7 5 2 kW 2 7 2 7 2 8 2 8 2 8 2 9 2 8 3 0 3 0 35 TC 7 7 8 5 9 3 7 9 8 5 9 4 8 1 8 6 9 4 SHC 7 1 5 9 4 7 7 6 6 2 4 9 7 8 6 6 5 0 kW 3 0 3 0 3 0 3 0 3 1 3 2 3 1 3 2 3 3 41 TC 7 4 8 0...

Page 12: ...1 9 6 8 0 6 2 10 1 8 3 6 3 kW 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 7 3 7 35 TC 9 6 10 6 11 6 9 8 10 7 11 6 9 9 10 8 11 6 SHC 8 9 7 4 5 9 9 4 7 8 6 1 9 9 8 1 6 1 kW 3 6 3 7 3 7 3 8 3 9 3 9 3 9 4 0 4 0 41 TC...

Page 13: ...16 0 13 7 15 2 16 3 14 1 15 5 16 5 SHC 12 1 10 1 7 9 13 1 10 9 8 3 14 1 11 5 8 6 kW 4 8 4 9 4 9 4 8 4 9 5 0 4 8 4 9 5 0 35 TC 12 5 14 1 15 5 12 9 14 4 15 8 13 4 14 7 16 0 SHC 11 7 9 8 7 7 12 7 10 6 8...

Page 14: ...mulas may be used C ldb C edb SHC kW x 1000 1 23 x L s Leaving wet bulb wet bulb temperature corresponding to enthalpy of air leaving coil h wb h wb h ewb TC kW x 1000 1 20 x L s Where h ewb is enthal...

Page 15: ...ducting NOTES 1 Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12 000 Btuh 165 L s for each 3 5 kW of rated cooling capacity Evaporator coil frosting may occur at airf...

Page 16: ...25 472 519 566 614 661 707 755 802 850 896 944 991 1038 1085 508X508X25 12 4 17 4 19 9 24 9 29 9 32 3 34 8 37 3 508X610x25 22 4 24 9 27 4 32 3 34 8 37 4 39 9 610X762x25 17 4 19 9 22 4 24 9 27 4 29 9 3...

Page 17: ...o convert a unit to downflow discharge Units are equipped with factory sealed covers in the downflow openings Maximum cooling airflow To minimize the possibility of condensate blow off from the evapor...

Page 18: ...ection RLA Rated Load Amps NOTES 1 In compliance with NEC National Electrical Code requirements for multimotor and combination load equipment refer to NEC Articles 430 and 440 the overcurrent protecti...

Page 19: ...19 TYPICAL WIRING SCHEMATIC 400 3 50 A09464 50GL A...

Page 20: ...sition de energizing the compressor contactor and opening the contacts supplying power to compressor OFM After a 90 second delay the IFM shuts off If the thermostat fan selector switch is in the ON po...

Page 21: ...awings 2 Fan wheel shall be made from steel be double inlet type with forward curved blades with corrosion resistant finish Fan wheel shall be dynamically balanced 3 Condenser fan shall be direct driv...

Page 22: ...onsist of damper birdscreen and rainhood which can be preset to admit outdoor air for year round ventilation 8 Square To Round Duct Transitions 24 48 size Shall have the ability to convert the supply...

Reviews: