27
1
: Set the reader in programming mode, see page: 23
2
: Present the “OSDP Installation mode Card” to the reader as shown. Keep the card
within reading distance until the reader beeps and blinks in green. The reader has now
reset the secure channel encryption keys to installation mode.
Note:
OSDP Installation Mode Cards Cards can be programmed to any MIFARE DESFire
EV1 or EV2 cards using the reader tool software and a LenelS2 Readers -
5000 series Reader connected to the reader tool using a RS485 to USB converter.
• Reader tool software and connection cable set, part no.
LNL-R50000-TOOL, LNL-R50000-TOOL-UK or LNL-R50000-TOOL-US
BEEP !
Resetting the OSDP
secure channel.
Reading distance
approximately 2 cm.
OSDP Installation mode Card, part no: LNL-C50000-OSDP