Step 8 —

Remove lockout tag and turn on the electrical supply

to unit.

Step 9 —

Open the external gas pipings manual shut off valve

located outside the unit.

Step 10 —

Set room thermostat temperature selector slightly

above room temperature and set system switch to HEAT position
to start the unit. The induced--draft combustion air fan will start.
Main burners light within 30 seconds. Indoor blower will start
within a few seconds of main gas ignition.

Step 11 —

Set the temperature selector on room thermostat to

desired setting.

HEAT
EXCHANGER
SECTION

IGC BOARD
(HIDDEN)

COMBUSTION
FAN HOUSING

MAIN BURNER
SECTION

INDUCED
DRAFT
MOTOR

MAIN GAS
VALVE

C07259

Fig. 1 -- Typical Gas Heating Section

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal injury,

death, and/or property damage.
If the main burners fail to light, or the blower fails to come on,

shut down gas heating section and call your dealer for service.

!

WARNING

TO LIGHT UNIT

(UNITS WITH

COMFORT

LINK

CONTROL)

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal injury,

death, and/or property damage.
1. Do not turn off the electrical power to unit without first

turning off the gas supply and apply lockout tags.

2. Before attempting to start the gas heating section, familiarize

yourself with all the procedures that must be followed.

3. Never attempt to manually light the burners on the unit with

a match, lighter, or any other flame. If the electric sparking

device fails to light the burners, refer to the shutdown

procedures, then call your dealer as soon as possible.

!

DANGER

Summary of Contents for 48HG14

Page 1: ...safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is...

Page 2: ...end on the type of unit control This section will help determine the control type of the unit Electro Mechanical Control These units may be controlled directly by a thermostat or indirectly by a third...

Page 3: ...FIRE EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property damage If the main burners fail to light or the blower fails to come on shut down gas heating...

Page 4: ...EP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 OFF ON CONTROL I D LABEL 1 4 X 032 MALE SPADE TERMINALS 2 COMMON SWITCH SHIPPED IN ON POSITION OFF ON CONTROL I D LABEL 1 4 X 032 MALE SPADE TERMINALS 2 COMMON...

Page 5: ...Status ENTER MODE ESCAPE Run Status Service Test Temperature Pressures Setpoints Inputs Outputs Configuration Time Clock Operating Modes Alarms Alarm Status ENTER MODE ESCAPE OFF ON CONTROL I D LABEL...

Page 6: ...ERVICE TEST mode Step 11 To test the operation of the gas section use the Scrolling Marquee test routine to energize the gas outputs and to turn on the gas Step 12 For normal operation make sure that...

Page 7: ...flash e Push the UP or DOWN key to toggle the display to YES and then push ENTER The unit will be locked off from heat cooling or any operation The controls will still function and the display will s...

Page 8: ...ting season has ended restore electrical power to the unit and take control out of Service Test mode to ensure operation of the cooling system during the cooling season MAINTAINING YOUR UNIT All maint...

Page 9: ...ble filters for the outdoor air These filters should be checked quarterly and cleaned as necessary Remove by pulling out the middle of the hood top Push up on the center filter and then remove Slide t...

Page 10: ...terly the condition of fan wheels and housings and belt tension When service is necessary call your dealer Fan Shaft Bearings Lubrication should only be done by qualified service personnel Contact you...

Page 11: ...dealer Is the electrical supply switch on Are any fuses blown or has the circuit breaker tripped During the heating season check the manual gas shutoff valve Is this lever parallel with the pipe indic...

Reviews: