Date:

Supersedes:

48GS(N)018-060/48GX(N)024-060

Single-Package

Gas Heating/

Electric Cooling Units

48GS-2SB

Rev.:

JOB DATA:

LOCATION:

BUYER:

BUYER P.O. #

CARRIER #

UNIT NUMBER:

MODEL NUMBER:

PERFORMANCE DATA CERTIFIED BY:

DATE:

  

3 2

5

A2

 

DESCRIPTION

 

 

 

48GS(N)/48GX(N) units are self-contained, gas heating/electric cooling
units designed for easy installation and maintenance and dependable per-
formance. All units have discharge openings for either horizontal or
downflow configuration, and all have low sound levels. Units are intend-
ed for outdoor installation and may be located on a rooftop, or a ground-
level concrete slab, or directly on the ground if local codes permit. 

• Standard one year limited warranty for both 48GS and

48GX.

• 10 year warranty on the 48GX(N) compressor.
• 5 year warranty on the 48GS(N) compressor.
• 15 year warranty on the 48GX(N) gas-fired heat ex-

changer.

• 10 year warranty on the 48GS(N) gas-fired heat exchanger.
• Units certified and listed by UL and c-UL. Units are rated

in accordance with ARI Standard 210.

• Low sound ratings.
• Units are pre-wired, pre-piped, and pre-charged for min-

imum installation expense.

• 12 SEER cooling efficiency.
• Lightweight.
• Compressor vibration isolation provides quieter operation.
• Energy saving, direct spark ignition.
• Easily converted for downflow operation with included

horizontal duct covers.

• Cabinets are constructed of heavy-duty, phosphated, zinc

coated pre-painted steel capable of withstanding 500
hours in salt spray.

• Easy-to-service cabinets with single-panel accessibility.
• Direct-drive multi-speed, permanent split capacitor

(PSC) indoor motor is standard.

• Direct-drive, PSC outdoor fan motor.
• Integrated gas control board provides safe and efficient

control of gas heating.

• Corrosion resistant gas heat exchangers.
• Coils constructed of aluminum fins bonded to copper

tubes.

• Wire grille provides additional protection.
• “Envirotuff” composite rust-proof unit base pan.
• Sloped drain pan minimizes standing water in the unit.
• Refrigerant service connections make checking operat-

ing pressures easier.

• Copper & pre-coated fin coils are available from the fac-

tory by special order, for use in corrosive environments.

• Low NOx units available for use in California.
•Three-phase units available.

 

FEATURES

 

Unit Operating Weight________lb (unit); ________lb 
(curb)

 

COOLING

 

Net Total Capacity____________________________Btuh
Net Sensible Capacity ________________________ Btuh
Compressor Power Input__________kW @  ________ °F
Outdoor-Air Temperature
Indoor Entering-Air db__________°F 

wb _________ °F

Seasonal Energy Efficiency Ratio ___________________
CFM__________ Ext. Static Pressure___________in. wg
Indoor Fan Motor______ Hp________ Rpm________Bhp

 

HEATING

 

Input ______________________________________ Btuh
Output ____________________________________ Btuh
AFUE _______________________________________ %
Power Input to Unit ___________________________ kW
Integrated Capacity __________________________ Btuh
Indoor Operating Temp _______________________°F db
Outdoor-Air Temp ________________°F (Winter Design)
COP/HSPF _________________Hi  _______________ Lo

 

PERFORMANCE DATA