UNIT INTRODUCTION

This unit is a small packaged gas heat/electric cooling system that
can utilize

the comfort of gas heating packaged along with

efficient electric air conditioning. This unit uses Puron

r

, the

ozone friendly refrigerant for cooling.

Starting or Shutting Off Unit

NOTE

: Your combination heating/cooling unit is equipped with

an automatic direct spark ignition and power combustion blower.

To start unit gas heat:

Refer to Fig. 2 for location of unit front access panel. Refer to Fig.

3 for location of gas valve. Refer to Fig. 4 while proceeding with

the following steps.

1. Set the temperature selector on room thermostat to the low-

est temperature setting and set system switch to HEAT.

2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16--in. nut driver.

(See Fig. 2.)

Compressor

Access

Panel

Filter Access Panel

For Accessory Filter Rack

Blower

Access

Panel

Control

Access

Panel

A09213

Fig. 2 -- Unit Access Panel

5. Move the selector switch on the internal gas valve to the

OFF position and wait 5 minutes.

6. Move the selector switch on the internal gas valve to the ON

position.

7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.

10. Set the temperature selector on room thermostat slightly

above room temperature to start unit. The induced--draft
combustion air fan will start. Main gas valve will open and

main burners should ignite within 5 seconds. If the burner
does not light within 5 seconds, the ignition module will go
into a Retry Mode after a period of approximately 22

seconds (following the 5--second ignition period). If the
burners do not light within 15 minutes of the initial call for

heat, there is a lockout.

11. Set the temperature selector on room thermostat to desired

setting.

FIRE AND EXPLOSION HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
1. If the main burners fail to light, or the blower fails to

start, shut down gas heating section and call your dealer for

service.

2. Never attempt to manually light the main burners on unit

with a match, lighter, or any other flame. If the electric

sparking device fails to light the main burners, refer to the

following shutdown procedures, then call your dealer as

soon as possible.

!

WARNING

Burners

Gas Valve

Flue Hood

A09043

Fig. 3 -- Gas Heating/Electric Cooling Unit with Access Panel

Removed

T

o shut off unit gas heat:

FIRE,

EXPLOSION,

ELECTRICAL

SHOCK

HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
Do not turn off the electrical power to unit without first

turning off the gas supply.

!

WARNING

NOTE

: If the unit is being shut down because of a malfunction,

call your dealer as soon as possible.

Should overheating occur or the gas supply fail to shut off, shut

off the external manual gas valve to the unit before shutting off

the electrical supply. Do not use this unit if any part has been under
water. Immediately call a qualified service technician to inspect the

unit and to replace any part of the control system and any gas

control which has been under water.
Refer to Fig. 5 while proceeding with the following steps.

1. Set the temperature selector on room thermostat to lowest

temperature setting and set system SWITCH to OFF.

2. Close the external manual shutoff valve.
3. Turn off the electrical power supply to the unit.
4. Remove the control access panel. (See Fig. 2.)
5. Move the selector switch on the internal gas valve to the

OFF position.

6. Replace the control access panel.

Summary of Contents for 48ES---A

Page 1: ...uire maintenance or service UNIT INFORMATION Model _____________________________________ Serial ______________________________________ ACCESSORIES List type of model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed________________________________ DEALERSHIP CONTACT INFOR...

Page 2: ...sonnel should install repair or service this equipment WARNING FIRE EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property damage Do not store or use combustible materials gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could res...

Page 3: ...ers do not light within 15 minutes of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting FIRE AND EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property damage 1 If the main burners fail to light or the blower fails to start shut down gas heating section and call your dealer for service 2...

Page 4: ...o COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot days your unit will run for longer periods at a time and have shorter off periods than on moderate days Gas Heat Mode With the SYSTEM or MODE control of your indoor thermostat set to HEAT your unit will run in heating mode until room temperature is raised to the level y...

Page 5: ...5 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 4 To Start Unit Gas Heat ...

Page 6: ...5 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 5 To Shut off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 Fig 6 To Start Unit Electric Cooling ...

Page 7: ... 090 115 130 1 each 24 x 14 x 1 610 x 356 x 25 mm 24 x 16 x 1 610 x 406 x 25 mm 60 090 115 130 1 each 24 x 16 x 1 610 x 406 x 25 mm 24 x 18 x 1 610 x 457 x 25 mm Units with bent indoor coil To replace or inspect filters in accessory filter rack See Fig 2 1 Remove the filter access panel using a 5 16 in nut driver 2 Remove the filter s by pulling it out of the unit If the filter s is dirty clean or...

Page 8: ...rical Controls and Wiring Electrical controls are difficult to check without proper instrumentation If there are any discrepancies in the operating cycle contact your local dealer and request service Refrigerant Circuit The refrigerant circuit is difficult to check for leaks without the proper equipment If inadequate cooling is suspected contact your local dealer for service EXPLOSION AND ENVIRONM...

Page 9: ...leaks in the refrigerant circuit Pressure check to determine appropriate refrigerant charge 12 Operational check of the unit to determine working conditions Repair or adjustment should be made at this time Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation Start ...

Page 10: ...r Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 12 15 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM48ES VL 05 Replaces NEW ...

Reviews: