4
42XPF
Clean filters and reposition them in the unit.
Keep the unit in operation for half a day in ventilation
(fan only) mode in order to dry all the internal parts.
Switch the electric mains supply off.
Take the batteries out of the controller.
Clean indoor and outdoor units.
Maintenance
•
Turn the unit off and switch the mains supply off.
Use only a clean, damp and soapy cloth.
Do not pour any liquids on the unit. Do not use
flammable liquids, solvents or abrasive powders.
Keep heat sources away from the unit and do not place
anything hot on it; panels may be damaged.
The remote control should only be cleaned with a dry
cloth. Occasionally clean the area around the outdoor
(leaves etc.) to avoid reduced air circulation.
The standard filters supplied are high-efficiency
washable and recyclable filters. For their maintenance,
open the grille without removing the two screws and the
central clamp from their position (See fig. 17)
Acrylic-fibre filters (See fig. 17 B)
• The acrylic-fibre air filters can be washed with water.
• Remove the filters.
• First clean the filters with a vacuum cleaner, and then
rinse them under running water, and dry them
(See fig. 18).
• Correctly re-insert the filter in its position.
Photocatalytic filters (See fig. 17 A)
• Clean these filters every three months. Wash them
with water, and leave them for 2/3 hours to dry in
sunlight.
• Replace them approximately every five years.
Periodical checks
Correct cleaning
Filter cleaning
Before a long shutdown period
For a good operation of the air conditioner it is recommended to carry out checks and maintenance as indicated.
Recommended maintenance intervals may vary depending on the installation environment, e.g. dusty zones, etc.
(1) Increase frequency in dusty zones. (2) Operations to be carried out by qualified service personnel.
Every month
Every 4 months
Every year
Indoor unit: clean air
filter (1)
Clean drain pipe
Clean outdoor coil from
outside
Change controller batteries
Outdoor unit (2): Clean outdoor coil from inside;
Blow air over electric parts; Check electric connection
tightening; Clean fan wheel; Check fan tightening; Clean
drain pan