background image

1

Press 

 : Move the louver in 

the desired vertical direction.

2

Press 

 : Swing the air 

automatically and press again to stop.

3

For horizontal direction, adjust 
manually.

Note:

 •  Do not move the louver manually by others.
 •  

The louver may automation positioning by some operation mode.

1

   Infrared signal emitter

2

   Start/Stop button (

)

3

   Mode select button (

)

4

   Temperature button (

)

5

   Fan speed button (

)

6

   Swing louver button (

)

7

   Set louver button (

)

8

   On timer button (

)

9

   Off timer button (

)

!

   ECO  Sleep button (

)

"

   Setup button (

)

#

   Clear button (

$

   Memory and Preset button (

)

%

   High power button (

)

&

   Economy  button  (

)

(

   Quiet button (

)

)

   Filter reset button (

)

~

   Set clock button (

)

+

   Check button (

)

,

   Reset button (

)

1.  Press 

 : Select Cool 

, Heat 

, or Fan only 

.  

2.  Press 

 : Set the desired temperature.

  Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only:

No temperature indication

3.  Press 

 : Select AUTO, LOW  , LOW+ 

, MED

 , MED+

or HIGH 

For dehumidification, a moderate cooling performance is controlled automatically.

 1. 

Press 

 : Select Dry

.

 2. 

Press 

 : Set the desired temperature. 

To automatically control room temperature and airflow for faster cooling or heating 
operation (except in DRY and FAN ONLY mode)

Press 

 : Start and stop the operation.

To automatically control room to save energy (except in DRY and FAN ONLY 
mode)

Press 

 : Start and stop the operation.

Note: 

Cooling operation; the set temperature will increase automatically 1 degree/ 
hour for 2 hours (maximum 2 degrees increase). For heating operation the 
set temperature will decrease.

In case of the misplaced or discharged remote control

•  

Pressing the RESET button, the unit can start or 
stop without using the remote control.

•   Operation mode is set on AUTOMATIC operation, 

preset temperature is 24°C and fan operation is 
automatic speed.

Set the timer when the air conditioner is operating.

Setting ON Timer

Setting OFF Timer

1

Press 

 :  Set the desired ON 

timer.

Press 

 :  Set the desired OFF 

timer.

2

Press 

 : Set the timer.

Press 

 : Set the timer.

3

Press 

 : Cancel the timer.

Press 

 : Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be 
activated on a daily basis.

Setting Everyday Timer

1

Press 

  : Set the ON timer.

3

Press 

.

2

Press 

 : Set the OFF timer.

4

Press 

 button during 

the (  or  ) mark flashing.

•   During the every day timer is activating, both arrows ( ,  ) are indicated.

Note:

•   Keep the remote control in accessible transmission to the indoor unit; 

otherwise, the time lag of up to 15 minutes will occur.

•   The setting will be saved for the next same operation.

Preparing Filters

1. Open the air inlet grille and remove the air filters.
2. Attach the filters. (see detail in the accessory sheet).

Loading Batteries (when use wireless operation.)

1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) 
   following the (+) and (–) positions.

Clock Setup

1. Push 

 by tip of the pencil.  

  If timer indication is flashing, go to the next step 2.

2. Press 

 or 

 : adjust the time. 

3. Press 

 : Set the time. 

Remote Control Reset

Push 

 by tip of the pencil or

1. Remove the battery.

2. Press 

.

3. Insert the battery.

PREPARATION BEFORE USE

2

AIRFLOW DIRECTION

3

REMOTE CONTROL

4

To automatically select cooling, heating or fan only operation

1.  Press 

 : Select A.

2.  Press 

 : Set the desired temperature.

3.  Press 

 : Select AUTO, LOW  , LOW+ 

, MED

 , MED+

or HIGH 

AUTOMATIC OPERATION

5

COOLING / HEATING / FAN ONLY OPERATION

6

DRY OPERATION

7

Hi-POWER OPERATION

8

ECO OPERATION

9

TEMPORARY OPERATION

10

TIMER OPERATION

11

4

5

%

(

9

)

"
,

#

~

8

1

$

2

3

!

&

+

6

7

Note:

 •  The provided Remote Controller is a wireless type, which also can be used as 
  a wire. Please see “How to Connect The Remote Controller for Wired 
  Operation”, located in installation instruction, in case of wired control is required.
 •  In wire operation, remote controller will return to initial condition (PRESET, 
  TIMER and CLOCK will return to initial condition) when user shutdown power 
  supply of Air conditioner.

EN

Carrier1110655103(01_EN).indd   3

Carrier1110655103(01_EN).indd   3

2/6/13   3:19 PM

2/6/13   3:19 PM

Summary of Contents for 42UQV025M Series

Page 1: ...eneral public use Indoor unit 42UQV025M 035M 050M 060M Series Outdoor unit 38UYV025M 035M 050M 060M Series 1110655103 PORTUGU S P C FRAN AIS ESPA OL ENGLISH Carrier1110655103 CVF indd 1 Carrier1110655...

Page 2: ...y result in a failure or explosion of the product or an injury to your body PRECAUTIONS FOR SAFETY CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly...

Page 3: ...et the desired OFF timer 2 Press Set the timer Press Set the timer 3 Press Cancel the timer Press Cancel the timer Daily timer allows the user to set both the ON OFF timers and will be activated on a...

Page 4: ...The circuit breaker is activated to cut off the power supply Stoppage of electric current ON timer is set The filters are blocked with dust The temperature has been set improperly The windows or door...

Page 5: ...a a c a p e y pa y a a e e ee 3 PE PE EH E He ep a e c p a e c x y a c He c a e a a e pe e epc x a x a yxa MEP I E O ACHOCT PE OCTEPE EH E 80 1 a a Hi POWER 2 a a FILTER 3 4 a a TIMER 5 a a OPERATION...

Page 6: ...a a epa a ep e yc a E E a pye c e e e Hac p a e e e a epa 1 Ha e y c a e pe a epa e 3 Ha e y 2 Ha e y c a e pe a epa e 4 Ha e y a y e a c a cpa a ae e e e a ep pa a c e c pe p e a e y e ax c a pacc p...

Page 7: ...CO SLEEP 15 PA OTA B PE ME QUIET EC MH 14 ABTOMAT EC OBTOPH C 13 C a a a e a a ec a e RESET FILTER B y pe y a pe ye c c e y pe y a a He c y e e pa a e p a p x ec pa a e cpe c a y a e TE H EC OE O C BA...

Page 8: ...MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU AHI CARRIER S E EUROPE AIR CONDITIONING S A Address city cou...

Reviews: