Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2.
Press and hold
for 3 seconds to memorize the setting. The
P
mark displays.
3.
Press
: Operate the preset operation.
To automatically restart the air conditioner after the power failure (Power of the
unit must be on.)
Setting
1.
Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5
seconds)
2.
Press and hold the RESET button on the indoor unit for 3 seconds to cancel
the operation. (3 beep sound but OPERATION lamp does not blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
For ECO sleep automatically control air fl ow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note:
The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
: Start and stop the operation.
Note:
Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
Firstly, turn off the circuit breaker.
Filter Reset
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
1.
Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2.
Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room Temperature
Cooling
21°C ~ 43°C
21°C ~ 32°C
Dry
19°C ~ 43°C
17°C ~ 32°C
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil.
“00” will be shown on the display.
4. Press
during pushing
. “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note:
1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
The unit does not operate.
Cooling is abnormally low.
• The power main switch is turned off.
• The circuit breaker is activated to cut
off the power supply.
• Stoppage of electric current
• ON timer is set.
• The fi lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or DRY.
2
1
PRESET OPERATION
12
ECO SLEEP OPERATION
QUIET OPERATION
15
14
AUTO RESTART OPERATION
13
MAINTENANCE
16
OPERATION AND PERFORMANCE
17
TROUBLESHOOTING (CHECK POINT)
18
REMOTE CONTROL A-B SELECTION