background image

     TEMPORARY OPERATION

12

In case of the misplaced or discharged remote control 

 

●   Pressing the RESET button, the unit can start 

    or stop without using the remote control.

 

●   Operation mode is set on AUTOMATIC 

    operation, preset temperature is 24°C and fan 

    operation is automatic speed.

     SELF CLEANING OPERATION

     (COOL AND DRY OPERATION ONLY)

14

To protect bad smell caused by the humidity in the indoor unit.

  1.  If the 

  button is pressed once during “Cool” or “Dry” mode,

    the fan will continue to run for other 30 minutes, then it will turn off

    automatically. This will reduce the moisture in the indoor unit.
  2.  To stop the unit immediately, press the 

  

more 2 times 

    within 30 seconds.

     MAINTENANCE

15

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

 

●   Clean the indoor unit and the remote control with a wet cloth when 

  needed.
 

●   No benzine, thinner, polishing powder or chemically-treated duster.

Air filters

Clean every 2 weeks.

  1. Open the air inlet grille.

  2. Remove the air filters.

  3. Vacuum or wash and then dry them.

  4. Reinstall the air filters and close the air inlet grille.

     TROUBLESHOOTING (CHECK POINT)

17

The unit does not operate.

Cooling or Heating is abnormally low.

● The power main switch is

    turned off.

● The circuit breaker is

    activated to cut off the power

   supply.

 Stoppage of electric current.

● ON timer is set.

● The filters are blocked with dust.

 The temperature has been set

improperly.

● The windows or doors are opened.

 The air inlet or outlet of the outdoor 

unit is blocked.

● The fan speed is too low.

● The operation mode is FAN or DRY. 

● POWER SELECTION function is

   set 75% or 50% 

(This function is

   depend on remote controller)

.

     REMOTE CONTROL A-B SELECTION

18

To separate using of remote control for each indoor unit in case of 2 air

conditioner are installed nearly.

Remote Control B Setup.

  1.  Press RESET button on the indoor unit to turn the air conditioner ON.
  2.  Point the remote control at the indoor unit.
  3.  Push and hold

 

 button on the Remote Control by the tip of the

    pencil. “00” will be shown on the display. (Picture 

1

)

  4.  Press 

  during pushing 

. “B” will show on the display

    and “00” will disappear and the air conditioner will turn OFF. The 

    Remote Control B is memorized. (Picture 

2

)

Note:

 1. Repeat above step to reset Remote Control to be A.

    2. Remote Control A has not “A” display.
    3. Default setting of Remote Control from factory is A.

1

                         

2

     AUTO RESTART FUNCTION SETTING

13

This product is designed so that, after a power failure, it can restart

automatically in the same operating mode as before the power failure.

Information

     The product is shipped with Auto Restart function in the ON position.
     Turn it OFF if this function is not required.

How to turn OFF the Auto Restart Function

     

● Press and hold the [OPERATION] button on the indoor unit for 3 seconds  

       (3 beep sounds but OPERATION lamp does not blink).

How to turn ON the Auto Restart Function

     

● Press and hold the [OPERATION] button on the indoor unit for 3 seconds 

       (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).

Note:

     

● In case of ON timer or OFF timer are set, AUTO RESTART OPERATION 

       does not activate.

     OPERATION AND PERFORMANCE

16

1.  Three-minute protection feature: To prevent the unit from being 

  activated for 3 minutes when suddenly restarted or switched to ON.
2.  Some minor cracking sound may occur when unit operating. This is

  normal because the cracking sound may be caused by expansion/

  contraction of plastic. 

Air conditioner operating conditions

                        Temp. 

 Operation          

Outdoor Temperature

Room Temperature

 Cooling

21°C ~ 43°C

21°C ~ 32°C

 Dry

19°C ~ 43°C

17°C ~ 32°C

1144180208-EN,TH.indd   5

22/12/2564   8:21:32

Summary of Contents for 42TSAA010

Page 1: ...OWNER S MANUAL ENGLISH AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TSAA010 013 018 025 Outdoor unit 38TSAA010 013 018 025 1144180208 1144180208 EN TH indd 1 22 12 2564 8 21 31...

Page 2: ...ng The appliance must be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater In order to avoid fire expl...

Page 3: ...Else it may explode and cause injury or death Appliance and pipe work shall be installed operated and stored in a room with a floor area larger than Amin m2 How to get Amin m2 Amin M 2 5 x 0 22759 x h...

Page 4: ...CHECK 1 Press Select Cool or Fan only 2 Press Set the desired temperature Min 17 C Max 30 C Fan Only No temperature indication 3 Press Select AUTO LOW LOW MED MED or HIGH For dehumidification a modera...

Page 5: ...te control for each indoor unit in case of 2 air conditioner are installed nearly Remote Control B Setup 1 Press RESET button on the indoor unit to turn the air conditioner ON 2 Point the remote contr...

Page 6: ...R32 BURST HAZARD Open the service valves before the operation otherwise there might be the burst CAUTION 3 1144180208 EN TH indd 6 22 12 2564 8 21 32...

Page 7: ...R32 Amin m2 Amin m2 Amin M 2 5 x 0 22759 x h0 2 M h0 0 6 1 8 1 0 2 2 2 5 1144180208 EN TH indd 7 22 12 2564 8 21 32...

Page 8: ...1144180208 EN TH indd 8 22 12 2564 8 21 32...

Page 9: ...C Auto 8 9 1 1 2 2 10 1 2 0 5 12 3 4 1 2 3 1 2 3 4 5 6 7 8 9 0 CLEAR CHECK 1 2 3 7 9 8 4 6 5 0 1 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH 5 1 Auto A 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH 5 LCD 100 5...

Page 10: ...OMATIC 24 C 2 1 2 3 4 15 17 ON FAN DRY 75 50 1 2 B 1 RESET 2 3 00 1 4 B 00 B 2 1 A 2 A A 3 A A B 18 13 16 1 3 2 21 C 43 C 21 C 32 C 19 C 43 C 17 C 32 C OPERATION 3 3 OPERATION 3 3 5 5 1144180208 EN TH...

Page 11: ...1144180208 EN TH indd 11 22 12 2564 8 21 33...

Page 12: ...1144180208 1144180208 EN TH indd 12 22 12 2564 8 21 33...